Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2407.05569 · Physical Review Applied

Master-equation-based model for infrared-based magnetometry with nitrogen-vacancy-centers-in-diamond cavities: A path to subpicotesla sensitivity at submillimeter scales

Hadi Zadeh‐Haghighi, Omid Golami, Vinaya K. Kavatamane, Paul E. Barclay, Christoph Simon

Published Dec 3, 2024• 5 citations
arXivHTMLPDF

Abstract

Our study aims to increase the spatial resolution of high-sensitivity magnetometry based on singlet-transition infrared (IR) absorption using nitrogen-vacancy ($\mathrm{N}$-$V$) centers in diamond in monolithic cavities, with potential applications in biomagnetic field detection. We develop a master-equation treatment of optically detected magnetic resonance, incorporating IR light saturation effects. This master equation provides the singlet population, which is then utilized to calculate the reflectivity and ultimately derive the magnetic field sensitivity taking into account photon and spin shot noise. We further show that our model is compatible with experiments of IR-based $\mathrm{N}$-$V$-center magnetometry. Through optimization in a high-parameter space, we uncover the potential to achieve sensitivities in the order of subpicotesla, even for submillimeter scales.

DOI
10.1103/physrevapplied.22.064015

Related papers

Towards high-sensitivity magnetometry with nitrogen-vacancy centers in diamond using the singlet infrared absorption

Ali Tayefeh Younesi, Muhib Omar, Arne Wickenbrock +2 more

The negatively charged nitrogen vacancy center in diamond is widely used for quantum sensing due to the sensitivity of the spin triplet in the electronic ground state to external perturbations such as strain and electromagnetic fields, which makes it an excellent probe for changes in these perturbations. The spin state can be measured through optically detected magnetic resonance, which is most commonly achieved by detecting the photoluminescence after exciting the spin-triplet transition. Recently, methods have been proposed and demonstrated that use the absorption of the infrared singlet transition at 1042 nm instead. These methods, however, require cryogenic temperatures or external cavities to enhance the absorption signal. Here, we report on our efforts to optimize the magnetometer sensitivity at room temperature and without cavities. We reach a sensitivity of 18 pT / Hz , surpassing previously reported values, and a calculated shot-noise limit of 5 pT / Hz . We also report on a defect that is native to diamond grown by chemical vapor deposition and thus absent in high-pressure high-temperature diamond, the excitation of which impacts the measured singlet absorption signal.

arXiv:2410.20876•Physical Review Applied•May 7, 2025•16 citations

Cavity-Enhanced Room-Temperature Magnetometry Using Absorption by Nitrogen-Vacancy Centers in Diamond

Kasper Jensen, N. Leefer, Andrey Jarmola +5 more

We demonstrate a cavity-enhanced room-temperature magnetic field sensor based on nitrogen-vacancy centers in diamond. Magnetic resonance is detected using absorption of light resonant with the 1042 nm spin-singlet transition. The diamond is placed in an external optical cavity to enhance the absorption, and significant absorption is observed even at room temperature. We demonstrate a magnetic field sensitivity of $2.5\text{ }\text{ }\mathrm{nT}/\sqrt{\mathrm{Hz}}$, and project a photon shot-noise-limited sensitivity of $70\text{ }\text{ }\mathrm{pT}/\sqrt{\mathrm{Hz}}$ for a few mW of infrared light, and a quantum projection-noise-limited sensitivity of $250\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ for the sensing volume of $\ensuremath{\sim}90\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{m}\ifmmode\times\else\texttimes\fi{}90\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{m}\ifmmode\times\else\texttimes\fi{}200\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{m}$.

arXiv:1401.2438•Physical Review Letters•Apr 23, 2014•148 citations

High-contrast absorption magnetometry in the visible to near-infrared range with nitrogen-vacancy ensembles

Florian Schall, Felix A. Hahl, Lukas Lindner +6 more

Magnetometry with nitrogen-vacancy (NV) centers in diamond has so far been measured via emission of light from NV centers or via absorption at the singlet transition at 1042 nm. Here, we demonstrate a phenomenon of broadband optical absorption by the NV centers starting in the emission wavelength and reaching up to 1000 nm. The measurements are enabled by a high-finesse cavity, which is used for room-temperature continuous wave pump-probe experiments. The red to infrared probe beam shows the typical optically detected magnetic resonance (ODMR) signal of the NV spin with contrasts up to 42 %. This broadband optical absorption has not yet been reported in terms of NV magnetometry. We argue that the lower level of the absorbing transition could be the energetically lower NV singlet state, based on the increased optical absorption for a resonant microwave field and the spectral behavior. Investigations of the photon-shot-noise-limited sensitivity show improvements with increasing probe wavelength, reaching an optimum of 7.5pT/Hz. The results show significantly improved ODMR contrast compared to emission-based magnetometry. This opens a new detection wavelength regime with coherent laser signal detection for high-sensitivity NV magnetometry.

arXiv:2412.07798•Optics Express•Jan 23, 2025•4 citations

Magnetometry with nitrogen-vacancy ensembles in diamond based on infrared absorption in a doubly resonant optical cavity

Yannick Dumeige, Mayeul Chipaux, V. Jacques +8 more

We propose using an optical cavity to enhance the sensitivity of a magnetometer relying on the detection of the spin state of a high-density nitrogen-vacancy ensemble in diamond using infrared optical absorption. The role of the cavity is to obtain a contrast in the absorption-detected magnetic resonance approaching unity at room temperature. We project an increase in the photon shot-noise limited sensitivity of two orders of magnitude in comparison with a single-pass approach. Optical losses can limit the enhancement to one order of magnitude, which could still enable room-temperature operation. Finally, the optical cavity also allows us to use less pumping power when the cavity is resonant at both the pump and the infrared probe wavelength.

arXiv:1301.0808•Physical Review B•Apr 8, 2013•79 citations

Nitrogen-vacancy ensemble magnetometry based on pump absorption

Sepehr Ahmadi, Haitham A. R. El-Ella, Adam M. Wojciechowski +4 more

We demonstrate magnetic-field sensing using an ensemble of nitrogen-vacancy centers by recording the variation in the pump-light absorption due to the spin-polarization dependence of the total ground-state population. Using a 532 nm pump laser, we measure the absorption of native nitrogen-vacancy centers in a chemical-vapor-deposited diamond placed in a resonant optical cavity. For a laser pump power of 0.4 W and a cavity finesse of 45, we obtain a noise floor of $\ensuremath{\sim}100 \mathrm{nT}/\sqrt{\mathrm{Hz}}$ spanning a bandwidth up to 125 Hz. We project a photon shot-noise-limited sensitivity of $\ensuremath{\sim}1 \mathrm{pT}/\sqrt{\mathrm{Hz}}$ by optimizing the nitrogen-vacancy concentration and the detection method.

arXiv:1712.05161•Physical review. B./Physical review. B•Jan 11, 2018•23 citations

Competition between contrast and laser noise in laser threshold magnetometry using an external cavity diode laser

Shao Qi Lim, Alexander A. Wood, Brett C. Johnson +9 more

The negatively charged nitrogen-vacancy center (NV$^-$) in diamond is a versatile platform for quantum magnetometry under ambient conditions. Recently, laser threshold magnetometry (LTM) has been proposed as a means to significantly enhance the sensitivity of NV-based magnetometers by incorporating a diamond hosting NV$^-$ centers within a laser cavity and operating near threshold. While demonstrations have validated the concept, practical implementations remain technically demanding, requiring high pump powers and precise alignment of free-space cavities. It remains unclear whether the benefits of operating near threshold will outpace increased laser noise. In this work, we integrate an NV-diamond with a high NV$^-$ content into a compact external cavity diode laser and demonstrate singlet infrared absorption optically detected magnetic resonance (ODMR). We report a five-fold enhancement in the ODMR contrast by operating near the laser threshold. However, the magnetic-field sensitivity is a factor of two worse near threshold ($17~\mathrm{nT/\sqrt{Hz}}$) than when operating far above threshold ($7.6~\mathrm{nT/\sqrt{Hz}}$). Consequently, on this platform, near-threshold operation currently yields a net negative effect on sensitivity because the threshold-enhanced laser noise outweighs the threshold-enhanced contrast. These results demonstrate that managing this contrast-noise trade-off is a critical challenge that must be addressed to realize the potential benefits of laser threshold magnetometry.

quant-pharXiv:2604.18937•Apr 22, 2026•1 citation
Our study aims to increase the spatial resolution of high-sensitivity magnetometry based on singlet-transition infrared (IR) absorption using nitrogen-vacancy (N\mathrm{N}N-VVV) centers in diamond in monolithic cavities, with potential applications in biomagnetic field detection. We develop a master-equation treatment of optically detected magnetic resonance, incorporating IR light saturation effects. This master equation provides the singlet population, which is then utilized to calculate the reflectivity and ultimately derive the magnetic field sensitivity taking into account photon and spin shot noise. We further show that our model is compatible with experiments of IR-based N\mathrm{N}N-VVV-center magnetometry. Through optimization in a high-parameter space, we uncover the potential to achieve sensitivities in the order of subpicotesla, even for submillimeter scales.
The negatively charged nitrogen vacancy center in diamond is widely used for quantum sensing due to the sensitivity of the spin triplet in the electronic ground state to external perturbations such as strain and electromagnetic fields, which makes it an excellent probe for changes in these perturbations. The spin state can be measured through optically detected magnetic resonance, which is most commonly achieved by detecting the photoluminescence after exciting the spin-triplet transition. Recently, methods have been proposed and demonstrated that use the absorption of the infrared singlet transition at 1042 nm instead. These methods, however, require cryogenic temperatures or external cavities to enhance the absorption signal. Here, we report on our efforts to optimize the magnetometer sensitivity at room temperature and without cavities. We reach a sensitivity of 18 pT / Hz , surpassing previously reported values, and a calculated shot-noise limit of 5 pT / Hz . We also report on a defect that is native to diamond grown by chemical vapor deposition and thus absent in high-pressure high-temperature diamond, the excitation of which impacts the measured singlet absorption signal.
We demonstrate a cavity-enhanced room-temperature magnetic field sensor based on nitrogen-vacancy centers in diamond. Magnetic resonance is detected using absorption of light resonant with the 1042 nm spin-singlet transition. The diamond is placed in an external optical cavity to enhance the absorption, and significant absorption is observed even at room temperature. We demonstrate a magnetic field sensitivity of 2.5  nT/Hz2.5\text{ }\text{ }\mathrm{nT}/\sqrt{\mathrm{Hz}}2.5  nT/Hz​, and project a photon shot-noise-limited sensitivity of 70  pT/Hz70\text{ }\text{ }\mathrm{pT}/\sqrt{\mathrm{Hz}}70  pT/Hz​ for a few mW of infrared light, and a quantum projection-noise-limited sensitivity of 250  fT/Hz250\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}250  fT/Hz​ for the sensing volume of $\ensuremath{\sim}90\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{m}\ifmmode\times\else\texttimes\fi{}90\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{m}\ifmmode\times\else\texttimes\fi{}200\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{m}$.
Magnetometry with nitrogen-vacancy (NV) centers in diamond has so far been measured via emission of light from NV centers or via absorption at the singlet transition at 1042 nm. Here, we demonstrate a phenomenon of broadband optical absorption by the NV centers starting in the emission wavelength and reaching up to 1000 nm. The measurements are enabled by a high-finesse cavity, which is used for room-temperature continuous wave pump-probe experiments. The red to infrared probe beam shows the typical optically detected magnetic resonance (ODMR) signal of the NV spin with contrasts up to 42 %. This broadband optical absorption has not yet been reported in terms of NV magnetometry. We argue that the lower level of the absorbing transition could be the energetically lower NV singlet state, based on the increased optical absorption for a resonant microwave field and the spectral behavior. Investigations of the photon-shot-noise-limited sensitivity show improvements with increasing probe wavelength, reaching an optimum of 7.5pT/Hz. The results show significantly improved ODMR contrast compared to emission-based magnetometry. This opens a new detection wavelength regime with coherent laser signal detection for high-sensitivity NV magnetometry.
We propose using an optical cavity to enhance the sensitivity of a magnetometer relying on the detection of the spin state of a high-density nitrogen-vacancy ensemble in diamond using infrared optical absorption. The role of the cavity is to obtain a contrast in the absorption-detected magnetic resonance approaching unity at room temperature. We project an increase in the photon shot-noise limited sensitivity of two orders of magnitude in comparison with a single-pass approach. Optical losses can limit the enhancement to one order of magnitude, which could still enable room-temperature operation. Finally, the optical cavity also allows us to use less pumping power when the cavity is resonant at both the pump and the infrared probe wavelength.
We demonstrate magnetic-field sensing using an ensemble of nitrogen-vacancy centers by recording the variation in the pump-light absorption due to the spin-polarization dependence of the total ground-state population. Using a 532 nm pump laser, we measure the absorption of native nitrogen-vacancy centers in a chemical-vapor-deposited diamond placed in a resonant optical cavity. For a laser pump power of 0.4 W and a cavity finesse of 45, we obtain a noise floor of $\ensuremath{\sim}100 \mathrm{nT}/\sqrt{\mathrm{Hz}}$ spanning a bandwidth up to 125 Hz. We project a photon shot-noise-limited sensitivity of $\ensuremath{\sim}1 \mathrm{pT}/\sqrt{\mathrm{Hz}}$ by optimizing the nitrogen-vacancy concentration and the detection method.
The negatively charged nitrogen-vacancy center (NV−^-−) in diamond is a versatile platform for quantum magnetometry under ambient conditions. Recently, laser threshold magnetometry (LTM) has been proposed as a means to significantly enhance the sensitivity of NV-based magnetometers by incorporating a diamond hosting NV−^-− centers within a laser cavity and operating near threshold. While demonstrations have validated the concept, practical implementations remain technically demanding, requiring high pump powers and precise alignment of free-space cavities. It remains unclear whether the benefits of operating near threshold will outpace increased laser noise. In this work, we integrate an NV-diamond with a high NV−^-− content into a compact external cavity diode laser and demonstrate singlet infrared absorption optically detected magnetic resonance (ODMR). We report a five-fold enhancement in the ODMR contrast by operating near the laser threshold. However, the magnetic-field sensitivity is a factor of two worse near threshold (17 nT/Hz17~\mathrm{nT/\sqrt{Hz}}17 nT/Hz​) than when operating far above threshold (7.6 nT/Hz7.6~\mathrm{nT/\sqrt{Hz}}7.6 nT/Hz​). Consequently, on this platform, near-threshold operation currently yields a net negative effect on sensitivity because the threshold-enhanced laser noise outweighs the threshold-enhanced contrast. These results demonstrate that managing this contrast-noise trade-off is a critical challenge that must be addressed to realize the potential benefits of laser threshold magnetometry.