Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2405.18883 · Physical Review A

Characterization of ion-trap-induced ac magnetic fields

Manoj K. Joshi, Milena Guevara-Bertsch, Florian Kranzl, R. Blatt, Christian F. Roos

Published Dec 2, 2024• 1 citation
arXivHTMLPDF

Abstract

The oscillating magnetic field produced by unbalanced currents in radio-frequency ion traps induces transition frequency shifts and sideband transitions that can be harmful to precision spectroscopy experiments. Here, we describe a methodology, based on two-photon spectroscopy, for determining both the strength and direction of rf-induced magnetic fields without modifying any dc magnetic bias field or changing any trap rf power. The technique is readily applicable to any trapped-ion experiment featuring narrow linewidth transitions.

DOI
10.1103/physreva.110.063101

Related papers

AC Zeeman effect in microfabricated surface traps

Megan Ivory, Christopher Nordquist, Kevin C Young +3 more

Quantum processors and atomic clocks based on trapped ions often utilize an ion's hyperfine transition as the qubit state or frequency reference, respectively. These states are a good choice because they are insensitive in first order to magnetic field fluctuations, leading to long coherence times and stable frequency splittings. In trapped ions, however, these states are still subject to the second order AC Zeeman effect due to the necessary presence of an oscillating magnetic field used to confine the ions in a Paul trap configuration. Here, we measure the frequency shift of the 2S1/2 hyperfine transition of a 171Yb+ ion caused by the radio frequency (RF) electromagnetic field used to create confinement in several microfabricated surface trap designs. By comparing different trap designs, we show that two key design modifications significantly reduce the AC Zeeman effect experienced by the ion: (1) an RF ground layer routed directly below the entire RF electrode, and (2) a symmetric RF electrode. Both of these changes lead to better cancellation of the AC magnetic field and, thus, overall reduced frequency shifts due to the AC Zeeman effect and reduced variation across the device. These improvements enable a more homogeneous environment for quantum computing and can reduce errors for precision applications such as atomic clocks.

Review of Scientific Instruments•Sep 1, 2024•2 citations

Characterizing the AC Zeeman Effect in Microfabricated Surface Traps .

Susan Clark, Megan Ivory, Craig Hogle +3 more

Microfabricated surface traps have enabled precise control over trapped ions in a compact device with lower power requirements than traditional traps, but have also presented unique challenges due to the small ion-surface distance.One such challenge is AC Zeeman effect which leads to a frequency shift due to the oscillating magnetic field associated with the RF drive.Here, we characterize the frequency shift of the ground state microwave transition of a 171 Yb + ion confined by microfabricated surface traps driven by an RF field.We compare the AC Zeeman effect due to the drive RF and induced RF current in the trap ground planes for various traps fabricated at Sandia National Laboratories.

•Jul 1, 2022•0 citations

Characterization of rf field-induced a.c. Zeeman shift in multi-level highly charged ions

Shuying Chen, Lukas J. Spieß, Alexander Wilzewski +3 more

Characterization of the trap rf induced a.c. Zeeman shift is essential for achieving high accuracy in optical ion clocks. In this work, we demonstrate the experimental characterization of this shift using highly charged $\mathrm{Ca}^{14+}$. The transverse component of the a.c. magnetic field is measured using the Autler-Townes splitting of the equally-spaced Zeeman components of the $^{3}\mathrm{P}_1$ when the Zeeman splitting is close to resonance with the trap rf drive frequency. We observe the resulting modulation by performing quantum logic spectroscopy using the co-trapped $\mathrm{Be}^{+}$. The longitudinal component is measured from probing the $\mathrm{Be}^{+}$ magnetic field-insensitive hyperfine transition $|F=2,m_F=0 \rangle \rightarrow | F=1,m_F=0 \rangle$. We confirm the small influence of the a.c. Zeeman shift in highly charged ions. The employed techniques can easily be transferred to other multi-level atomic systems.

arXiv:2604.09481•Apr 10, 2026•0 citations

Individual Addressing of Trapped Ions and Coupling of Motional and Spin States Using rf Radiation

M. Johanning, A. Braun, Nuala Timoney +3 more

Individual electrodynamically trapped and laser cooled ions are addressed in frequency space using radio-frequency radiation in the presence of a static magnetic field gradient. In addition, an interaction between motional and spin states induced by an rf field is demonstrated employing rf optical double resonance spectroscopy. These are two essential experimental steps towards realizing a novel concept for implementing quantum simulations and quantum computing with trapped ions.

arXiv:0801.0078•Physical Review Letters•Feb 20, 2009•129 citations

Precision measurement of the Mg+25 ground-state hyperfine constant

Zhilin Xu, Ke Deng, H. Che +3 more

We report an experimental determination of the ground-state hyperfine constant $A$ of the $^{25}\mathrm{Mg}^{+}$ ions by measuring the $|{S}_{1/2},F=2,m=0\ensuremath{\rangle}$ to $|{S}_{1/2},F=3,m=0\ensuremath{\rangle}$ transition (0-0 transition) frequency of the two ground-state hyperfine energy levels. The frequency is measured by rf resonant method in a Paul trap under a magnetic field of about 0.1 mT. The result is $A=\ensuremath{-}596.254$ 248 7(42) MHz. Different frequency shifts and uncertainties are evaluated. The main effect is quadratic Zeeman shift. Since the Paul trap is driven by rf on the electrodes, ac magnetic field can be induced by the rf at the site of the ion. The ac magnetic field causes quadratic Zeeman shift for ion frequency standards and also reduces the coherence time when the ion acts as a quantum bit. Precision measurement of this ac magnetic field can help evaluating the related uncertainty when a single-ion optical clock is established on the trap.

Physical Review A•Nov 21, 2017•15 citations

Rotating-radio-frequency ion traps

Taro Hasegawa, J. J. Bollinger

We discuss a radio-frequency (rf) ion trap, the rotating-radio-frequency (rotating-rf) trap, in which the motion of a charged particle is described by trigonometric functions rather than the usual Mathieu functions of a normal rf trap. In the rotating-rf trap, a rotating quadrupole electric field confines charged particles, whereas in a normal rf trap, an oscillating quadrupole electric field does. Ion motion in a rotating-rf trap is a superposition of two nondegenerate circular secular motions and two corresponding circular micromotions. The cases of applying a uniform dc magnetic field or a quadrupole dc electric field in addition to the rotating-rf field are also discussed. Confinement in a rotating-rf trap can be tighter than in a normal linear rf trap with the same experimental parameter values.

Physical Review A•Oct 20, 2005•26 citations
The oscillating magnetic field produced by unbalanced currents in radio-frequency ion traps induces transition frequency shifts and sideband transitions that can be harmful to precision spectroscopy experiments. Here, we describe a methodology, based on two-photon spectroscopy, for determining both the strength and direction of rf-induced magnetic fields without modifying any dc magnetic bias field or changing any trap rf power. The technique is readily applicable to any trapped-ion experiment featuring narrow linewidth transitions.
Quantum processors and atomic clocks based on trapped ions often utilize an ion's hyperfine transition as the qubit state or frequency reference, respectively. These states are a good choice because they are insensitive in first order to magnetic field fluctuations, leading to long coherence times and stable frequency splittings. In trapped ions, however, these states are still subject to the second order AC Zeeman effect due to the necessary presence of an oscillating magnetic field used to confine the ions in a Paul trap configuration. Here, we measure the frequency shift of the 2S1/2 hyperfine transition of a 171Yb+ ion caused by the radio frequency (RF) electromagnetic field used to create confinement in several microfabricated surface trap designs. By comparing different trap designs, we show that two key design modifications significantly reduce the AC Zeeman effect experienced by the ion: (1) an RF ground layer routed directly below the entire RF electrode, and (2) a symmetric RF electrode. Both of these changes lead to better cancellation of the AC magnetic field and, thus, overall reduced frequency shifts due to the AC Zeeman effect and reduced variation across the device. These improvements enable a more homogeneous environment for quantum computing and can reduce errors for precision applications such as atomic clocks.
Microfabricated surface traps have enabled precise control over trapped ions in a compact device with lower power requirements than traditional traps, but have also presented unique challenges due to the small ion-surface distance.One such challenge is AC Zeeman effect which leads to a frequency shift due to the oscillating magnetic field associated with the RF drive.Here, we characterize the frequency shift of the ground state microwave transition of a 171 Yb + ion confined by microfabricated surface traps driven by an RF field.We compare the AC Zeeman effect due to the drive RF and induced RF current in the trap ground planes for various traps fabricated at Sandia National Laboratories.
Characterization of the trap rf induced a.c. Zeeman shift is essential for achieving high accuracy in optical ion clocks. In this work, we demonstrate the experimental characterization of this shift using highly charged Ca14+\mathrm{Ca}^{14+}Ca14+. The transverse component of the a.c. magnetic field is measured using the Autler-Townes splitting of the equally-spaced Zeeman components of the 3P1^{3}\mathrm{P}_13P1​ when the Zeeman splitting is close to resonance with the trap rf drive frequency. We observe the resulting modulation by performing quantum logic spectroscopy using the co-trapped Be+\mathrm{Be}^{+}Be+. The longitudinal component is measured from probing the Be+\mathrm{Be}^{+}Be+ magnetic field-insensitive hyperfine transition ∣F=2,mF=0⟩→∣F=1,mF=0⟩|F=2,m_F=0 \rangle \rightarrow | F=1,m_F=0 \rangle∣F=2,mF​=0⟩→∣F=1,mF​=0⟩. We confirm the small influence of the a.c. Zeeman shift in highly charged ions. The employed techniques can easily be transferred to other multi-level atomic systems.
We report an experimental determination of the ground-state hyperfine constant AAA of the 25Mg+^{25}\mathrm{Mg}^{+}25Mg+ ions by measuring the $|{S}_{1/2},F=2,m=0\ensuremath{\rangle}$ to $|{S}_{1/2},F=3,m=0\ensuremath{\rangle}$ transition (0-0 transition) frequency of the two ground-state hyperfine energy levels. The frequency is measured by rf resonant method in a Paul trap under a magnetic field of about 0.1 mT. The result is $A=\ensuremath{-}596.254$ 248 7(42) MHz. Different frequency shifts and uncertainties are evaluated. The main effect is quadratic Zeeman shift. Since the Paul trap is driven by rf on the electrodes, ac magnetic field can be induced by the rf at the site of the ion. The ac magnetic field causes quadratic Zeeman shift for ion frequency standards and also reduces the coherence time when the ion acts as a quantum bit. Precision measurement of this ac magnetic field can help evaluating the related uncertainty when a single-ion optical clock is established on the trap.
We discuss a radio-frequency (rf) ion trap, the rotating-radio-frequency (rotating-rf) trap, in which the motion of a charged particle is described by trigonometric functions rather than the usual Mathieu functions of a normal rf trap. In the rotating-rf trap, a rotating quadrupole electric field confines charged particles, whereas in a normal rf trap, an oscillating quadrupole electric field does. Ion motion in a rotating-rf trap is a superposition of two nondegenerate circular secular motions and two corresponding circular micromotions. The cases of applying a uniform dc magnetic field or a quadrupole dc electric field in addition to the rotating-rf field are also discussed. Confinement in a rotating-rf trap can be tighter than in a normal linear rf trap with the same experimental parameter values.