arXiv:2405.18883 · Physical Review A
Characterization of ion-trap-induced ac magnetic fields
Manoj K. Joshi, Milena Guevara-Bertsch, Florian Kranzl, R. Blatt, Christian F. Roos
Abstract
The oscillating magnetic field produced by unbalanced currents in radio-frequency ion traps induces transition frequency shifts and sideband transitions that can be harmful to precision spectroscopy experiments. Here, we describe a methodology, based on two-photon spectroscopy, for determining both the strength and direction of rf-induced magnetic fields without modifying any dc magnetic bias field or changing any trap rf power. The technique is readily applicable to any trapped-ion experiment featuring narrow linewidth transitions.