arXiv:2404.14345 · Journal of Applied Physics

Picotesla optically pumped magnetometer using a laser-written vapor cell with sub-mm cross section

Andrea Zanoni, K. Mouloudakis, Michael C. D. Tayler, Giacomo Corrielli, Roberto Osellame, Morgan W. Mitchell, Vito Giovanni Lucivero

Published Oct 9, 2024• 6 citations
arXivHTMLPDF

Abstract

We demonstrate a sensitive optically pumped magnetometer using rubidium vapor and 0.75 amg of nitrogen buffer gas in a sub-mm-width sensing channel excavated by femtosecond laser writing followed by chemical etching. The channel is buried less than 1 mm below the surface of its fused silica host material, which also includes reservoir chambers and micro-strainer connections, to preserve a clean optical environment. Using a zero-field-resonance magnetometry strategy and a sensing volume of 2.25 mm3, we demonstrate a sensitivity of ≈1pT/Hz at 10 Hz. The device can be integrated with photonic structures and microfluidic channels with 3D versatility. Its sensitivity, bandwidth, and stand-off distance will enable detection of localized fields from magnetic nanoparticles and μL NMR samples.

DOI
10.1063/5.0230180

Related papers

Towards a multi-channel zero-field optically pumped magnetometer for imaging

Ronja Rasser, Peter A. Koss, Svenja A. Knappe +1 more

Abstract We present a design for a multi-channel optically pumped zero-field magnetometer utilizing a 200-μm-thick Rubidium vapor cell. The vapor cell and its housing are designed to reduce the minimal distance between a magnetic sample and the sensing volume to about 1 mm, to optimize the effective spatial resolution. The thin vapor cell, filled with 2 atm of nitrogen as a buffer gas reduces the volume across which the magnetic field is averaged. The vapor cell is fully illuminated by a single laser beam, and the transmitted light is imaged onto a 4 x 4 photodiode array, allowing for simultaneous measurement of a magnetic field distribution with up to 16 channels. The performance of the magnetometer is studied for all channels. It is shown that the sensor can operate in the spin-exchange relaxation-free regime with a projected photon-shot noise limited noise floor of about 1 pT/Hz1/2 for a sensitive voxel size of approximately 600 μm x 600 μm x 200 μm.

EPJ Quantum Technology•Aug 13, 2025•7 citations

Femtotesla atomic magnetometry in a microfabricated vapor cell

W. C. Griffith, Svenja A. Knappe, John E. Kitching

We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.

Optics Express•Dec 9, 2010•183 citations

A Compact Single-Beam Optically Pumped Magnetometer Based on Absorption Detection

Jia-You Liou, Yi‐Hsuan Chen, Hsiang-An Chuang +5 more

We demonstrate a compact single-beam optically pumped magnetometer (OPM) employing a pure 87Rb microfabricated vapor cell with 500 Torr buffer gas. The residual magnetic field is actively minimized to below 400 pT through a combination of mu-metal magnetic shielding and internal compensation coils. We systematically characterize the OPM response as a function of laser detuning and optical intensity, and derive the magnetic-field sensitivity from the signal slope and noise amplitude spectral density. A best sensitivity of 11 fT/Hz^1/2 is achieved near the resonance transition at an optimal optical intensity, using a small cell volume of only 0.027 cm^3. Furthermore, a miniaturized OPM prototype was developed using a folded flexible printed circuit board (FPCB) to integrate the vapor cell, a compact heater, and magnetic-field coils into a cubic sensing head. Two coil configurations patterned directly on the FPCB were investigated. Under optimized operating conditions, the OPM prototype achieved a sensitivity of 66 fT/Hz^1/2. These results demonstrate that high-buffer-pressure single-beam OPMs can achieve excellent sensitivity, establishing a pathway toward compact and scalable arrays.

arXiv:2610.32795•Oct 23, 2026•0 citations

Femtotesla atomic magnetometry in a microfabricated vapor cell

W. C. Griffith, Svenja A. Knappe, John E. Kitching

We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.

APS•Mar 1, 2010•0 citations

Magnetometry using hot atomic vapors

Martín Romero, Fernando

We demonstrate an ultra-high sensitivity rf optical magnetometer based on a compact 5×5×8 mm3 Rubidium-87 vapor cell in a mu-metal shielded environment. The rf field is detected via a Faraday rotation effect on the linear polarization of a probe beam, and the resonance frequency is tuned via Zeeman effect by applying a static bias magnetic field to the cell. Sensitivities down to 3 fT/√Hz are achieved between 10 kHz and 100 kHz, which is a performance comparable to that of prior larger cells. An increase in the sensitivity with frequency and temperature has been observed.

•Jul 19, 2022•0 citations

Dual channel self-oscillating optical magnetometer

Jacopo Belfi, G. Bevilacqua, V. Biancalana +4 more

We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D2 line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment, and a spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field difference. Rejection of the common-mode noise allows for high-resolution magnetometry with a sensitivity of 2 pT/sqrt Hz. This sensitivity, in conjunction with long-term stability and a large bandwidth, makes it possible to detect water proton magnetization and its free induction decay in a measurement volume of 5 cm3.

arXiv:0812.1160•Journal of the Optical Society of America B•Apr 3, 2009•30 citations
We demonstrate a sensitive optically pumped magnetometer using rubidium vapor and 0.75 amg of nitrogen buffer gas in a sub-mm-width sensing channel excavated by femtosecond laser writing followed by chemical etching. The channel is buried less than 1 mm below the surface of its fused silica host material, which also includes reservoir chambers and micro-strainer connections, to preserve a clean optical environment. Using a zero-field-resonance magnetometry strategy and a sensing volume of 2.25 mm3, we demonstrate a sensitivity of ≈1pT/Hz at 10 Hz. The device can be integrated with photonic structures and microfluidic channels with 3D versatility. Its sensitivity, bandwidth, and stand-off distance will enable detection of localized fields from magnetic nanoparticles and μL NMR samples.
Abstract We present a design for a multi-channel optically pumped zero-field magnetometer utilizing a 200-μm-thick Rubidium vapor cell. The vapor cell and its housing are designed to reduce the minimal distance between a magnetic sample and the sensing volume to about 1 mm, to optimize the effective spatial resolution. The thin vapor cell, filled with 2 atm of nitrogen as a buffer gas reduces the volume across which the magnetic field is averaged. The vapor cell is fully illuminated by a single laser beam, and the transmitted light is imaged onto a 4 x 4 photodiode array, allowing for simultaneous measurement of a magnetic field distribution with up to 16 channels. The performance of the magnetometer is studied for all channels. It is shown that the sensor can operate in the spin-exchange relaxation-free regime with a projected photon-shot noise limited noise floor of about 1 pT/Hz1/2 for a sensitive voxel size of approximately 600 μm x 600 μm x 200 μm.
We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.
We demonstrate a compact single-beam optically pumped magnetometer (OPM) employing a pure 87Rb microfabricated vapor cell with 500 Torr buffer gas. The residual magnetic field is actively minimized to below 400 pT through a combination of mu-metal magnetic shielding and internal compensation coils. We systematically characterize the OPM response as a function of laser detuning and optical intensity, and derive the magnetic-field sensitivity from the signal slope and noise amplitude spectral density. A best sensitivity of 11 fT/Hz^1/2 is achieved near the resonance transition at an optimal optical intensity, using a small cell volume of only 0.027 cm^3. Furthermore, a miniaturized OPM prototype was developed using a folded flexible printed circuit board (FPCB) to integrate the vapor cell, a compact heater, and magnetic-field coils into a cubic sensing head. Two coil configurations patterned directly on the FPCB were investigated. Under optimized operating conditions, the OPM prototype achieved a sensitivity of 66 fT/Hz^1/2. These results demonstrate that high-buffer-pressure single-beam OPMs can achieve excellent sensitivity, establishing a pathway toward compact and scalable arrays.
We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.
We demonstrate an ultra-high sensitivity rf optical magnetometer based on a compact 5×5×8 mm3 Rubidium-87 vapor cell in a mu-metal shielded environment. The rf field is detected via a Faraday rotation effect on the linear polarization of a probe beam, and the resonance frequency is tuned via Zeeman effect by applying a static bias magnetic field to the cell. Sensitivities down to 3 fT/√Hz are achieved between 10 kHz and 100 kHz, which is a performance comparable to that of prior larger cells. An increase in the sensitivity with frequency and temperature has been observed.
We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D2 line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment, and a spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field difference. Rejection of the common-mode noise allows for high-resolution magnetometry with a sensitivity of 2 pT/sqrt Hz. This sensitivity, in conjunction with long-term stability and a large bandwidth, makes it possible to detect water proton magnetization and its free induction decay in a measurement volume of 5 cm3.