Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2404.13210 · Physical Review Applied

Laser-cooling 88 Sr to microkelvin temperature with an integrated-photonics system

Andrew R. Ferdinand, Zheng Luo, Sindhu Jammi, Zachary L. Newman, Grisha Spektor, Okan Koksal, Parth Patel, Daniel Sheredy, William D. M. Lunden, Akash Rakholia, Travis C. Briles, Wenqi Zhu, Martin M. Boyd, Amit Kumar Agrawal, Scott B. Papp

Published Mar 21, 2025• 12 citations
arXivHTMLPDF

Abstract

Optical lattice clocks generate pristine timing signals, which advance understanding of physics and open new application opportunities. However, the existing experimental apparatus for such clocks consists of numerous complicated subsystems, and are laborious to assemble. This Letter demonstrates the use of integrated photonics technologies to generate the free-space optical configuration needed to laser cool and trap atomic samples for a lattice clock and to create a frequency-comb supercontinuum to stabilize the lasers for the lattice clock. The authors assemble integrated photonics devices without active alignment, highlighting the potential for scalability in lattice-clock systems.

DOI
10.1103/physrevapplied.23.l031002

Related papers

Scalable infrastructure for strontium optical clocks with integrated photonics

Zheng Luo, Travis C. Briles, Andrew R. Ferdinand +17 more

Optical atomic clocks provide exceptionally accurate and precise signals for timekeeping and precision measurements, but they require high-power, free-space laser configurations that limit scalability. We introduce and explore a scalable infrastructure for strontium (Sr) optical-lattice clocks that incorporates co-design of atomic-beam slowing and a magneto-optical trap (MOT) from an effusion source, generation of complex, three-dimensional free-space laser configurations with a photonic integrated circuit (PIC) and metasurface (MS) optics, and laser stabilization to a frequency-comb supercontinuum generated with integrated nonlinear photonics. With these elements, we realize MOTs of all stable strontium isotopes ($^{84}$Sr, $^{86}$Sr, $^{87}$Sr, $^{88}$Sr) with populations commensurate with natural abundances, demonstrating precise beam control and robustness. Access to laser-cooled alkaline-earth atoms with scalable integrated photonics enables system engineering for optical clocks, quantum sensing, and quantum information, and our experiments demonstrate extensible technologies that advance toward a Sr optical clock largely free of bulk optics.

arXiv:2604.03229•Physical Review Applied•Nov 5, 2026•1 citation

Compact 88Sr Optical Lattice Clock System with Metasurface Optics for Laser Cooling

Zheng Luo, Andrew R. Ferdinand, Sindhu Jammi +12 more

We demonstrate a scalable, integrated photonics infrastructure for compact optical clocks. In this alignment-free MOT 88Sr atoms are cooled to 3 µK and loaded into an optical lattice, ready for ultranarrow clock transition interrogation.

Frontiers in Optics•Jan 1, 2024•0 citations

An optical lattice clock based on bosonic Sr

N. Poli, Marco G. Tarallo, M. Schioppo +2 more

We present experimental results for an optical lattice clock operating on the1S0harr3P0transition in88Sr, which is excited with the technique of magnetic field-induced spectroscopy To reduce the complexity of the setup we have developed a set of new experimental techniques that greatly simplifies the clock spectroscopy in Sr atoms. First, we developed a method for finding the clock transition that removes the need for extensive frequency metrology hardware and optical frequency combs. This technique exploits a near coincidence in the atomic wavelengths of the1S0harr3P0clock and1S0harr3P1second stage cooling transitions in Sr, which are only 5 THz far apart. This coincidence enables the use of an optical (transfer) cavity to reference the frequency of the clock transition relative to that of the much stronger coolign transition Second, all laser sources in the experimental setup are based on semiconductor technology, which greatly reduces the complexity of the apparatus. With this setup, about 10488Sr atoms are trapped in a 1D lattice formed by 200 mW of radiation tuned near the magic wavelength at 813 nm. Preliminar uncertainty budget for our optical lattice clock is also presented, with particular attention to density dependent collisions, which led to an unexpectedly high signal contrast for long interaction times.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•1 citation

Architecture for the photonic integration of an optical atomic clock

Zachary L. Newman, Vincent N. Maurice, Tara E. Drake +19 more

Laboratory optical atomic clocks achieve remarkable accuracy (now counted to 18 digits or more), opening possibilities to explore fundamental physics and enable new measurements. However, their size and use of bulk components prevent them from being more widely adopted in applications that require precision timing. By leveraging silicon-chip photonics for integration and to reduce component size and complexity, we demonstrate a compact optical-clock architecture. Here a semiconductor laser is stabilized to an optical transition in a microfabricated rubidium vapor cell, and a pair of interlocked Kerr-microresonator frequency combs provide fully coherent optical division of the clock laser to generate an electronic 22 GHz clock signal with a fractional frequency instability of one part in 10^13. These results demonstrate key concepts of how to use silicon-chip devices in future portable and ultraprecise optical clocks.

arXiv:1811.00616•Optica•May 16, 2019•673 citations

Improving lattice-light-shift uncertainty of an 171Yb optical clock with optimized cooling and trapping lasers

Chengquan Peng, Tao Zhang, Changyue Sun +7 more

Atoms confined in the optical lattice can be interrogated with Doppler- and recoil-free operation. However, if not properly controlled, the optical lattice may limit clock accuracy. To improve the lattice-light-shift uncertainty, the cooling and trapping lasers' frequency stability is optimized, and the atom's signal stability is enhanced. A ring-cavity Ti:sapphire laser is locked to the optical frequency comb, which is referenced to a 578 nm ultra-stable laser, and the beat note's stability is on the order of 10−16. Using a 10 cm Fabry–Pérot cavity referenced to the Ti:sapphire laser, the optical frequency stability is transferred to the 399 nm cooling laser, creating favorable conditions for evaluating the lattice-light-shift accurately. We reevaluate lattice-light-shift in our 171Yb optical lattice clock with an uncertainty of 8.1 × 10−18, which is an order lower than our previous result, and the magic frequency is determined to be 394 798 266.6(1.3) MHz.

Applied Physics Letters•Sep 9, 2024•2 citations

Comb-assisted ultrastable laser system for quantum technologies

Michele Giunta, Martin Wolferstetter, Nikolai Lilienfein +5 more

Quantum technologies are nowadays emerging as enabling tools for practical applications, such as quantum sensing, quantum computing and quantum metrology. Lasers play a central role in many of these technological platforms, e.g. for atomic clocks, ion-based or neutral atom-based quantum computers or atom interferometers. Here we present a complete laser system to cool, trap and control strontium atoms in an optical lattice or in tweezer arrays. A sub-Hz linewidth master laser, locked to a high-finesse optical cavity provides the frequency reference for an ultra-low noise comb. The rack-mounted laser system consists of all cooling, repumping, and clock lasers stabilized to the optical frequency comb. Each of the involved laser frequencies can therefore be tuned and mapped in the frequency domain with a high degree of stability. The system is controlled via a software interface, allowing to operate the cold-atom-based physics package autonomously. The system is tailored for the operation of 88Sr or 87Sr optical lattice clocks, or for quantum computing applications, but other sub-Hz lasers could be obtained by phase locking additional clock laser frequencies to the ultra-stable comb, enabling convenient and accurate optical frequency ratio measurements. The laser system architecture and the relevant characterization measurements will be presented, proposing some user-cases such as quantum computing and atom interferometry on strontium atoms. This represents a technological leap for quantum optics, allowing to explore further applications of quantum sensors outside a traditional lab.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•1 citation
Optical lattice clocks generate pristine timing signals, which advance understanding of physics and open new application opportunities. However, the existing experimental apparatus for such clocks consists of numerous complicated subsystems, and are laborious to assemble. This Letter demonstrates the use of integrated photonics technologies to generate the free-space optical configuration needed to laser cool and trap atomic samples for a lattice clock and to create a frequency-comb supercontinuum to stabilize the lasers for the lattice clock. The authors assemble integrated photonics devices without active alignment, highlighting the potential for scalability in lattice-clock systems.
Optical atomic clocks provide exceptionally accurate and precise signals for timekeeping and precision measurements, but they require high-power, free-space laser configurations that limit scalability. We introduce and explore a scalable infrastructure for strontium (Sr) optical-lattice clocks that incorporates co-design of atomic-beam slowing and a magneto-optical trap (MOT) from an effusion source, generation of complex, three-dimensional free-space laser configurations with a photonic integrated circuit (PIC) and metasurface (MS) optics, and laser stabilization to a frequency-comb supercontinuum generated with integrated nonlinear photonics. With these elements, we realize MOTs of all stable strontium isotopes (84^{84}84Sr, 86^{86}86Sr, 87^{87}87Sr, 88^{88}88Sr) with populations commensurate with natural abundances, demonstrating precise beam control and robustness. Access to laser-cooled alkaline-earth atoms with scalable integrated photonics enables system engineering for optical clocks, quantum sensing, and quantum information, and our experiments demonstrate extensible technologies that advance toward a Sr optical clock largely free of bulk optics.
We present experimental results for an optical lattice clock operating on the1S0harr3P0transition in88Sr, which is excited with the technique of magnetic field-induced spectroscopy To reduce the complexity of the setup we have developed a set of new experimental techniques that greatly simplifies the clock spectroscopy in Sr atoms. First, we developed a method for finding the clock transition that removes the need for extensive frequency metrology hardware and optical frequency combs. This technique exploits a near coincidence in the atomic wavelengths of the1S0harr3P0clock and1S0harr3P1second stage cooling transitions in Sr, which are only 5 THz far apart. This coincidence enables the use of an optical (transfer) cavity to reference the frequency of the clock transition relative to that of the much stronger coolign transition Second, all laser sources in the experimental setup are based on semiconductor technology, which greatly reduces the complexity of the apparatus. With this setup, about 10488Sr atoms are trapped in a 1D lattice formed by 200 mW of radiation tuned near the magic wavelength at 813 nm. Preliminar uncertainty budget for our optical lattice clock is also presented, with particular attention to density dependent collisions, which led to an unexpectedly high signal contrast for long interaction times.
Laboratory optical atomic clocks achieve remarkable accuracy (now counted to 18 digits or more), opening possibilities to explore fundamental physics and enable new measurements. However, their size and use of bulk components prevent them from being more widely adopted in applications that require precision timing. By leveraging silicon-chip photonics for integration and to reduce component size and complexity, we demonstrate a compact optical-clock architecture. Here a semiconductor laser is stabilized to an optical transition in a microfabricated rubidium vapor cell, and a pair of interlocked Kerr-microresonator frequency combs provide fully coherent optical division of the clock laser to generate an electronic 22 GHz clock signal with a fractional frequency instability of one part in 10^13. These results demonstrate key concepts of how to use silicon-chip devices in future portable and ultraprecise optical clocks.
Atoms confined in the optical lattice can be interrogated with Doppler- and recoil-free operation. However, if not properly controlled, the optical lattice may limit clock accuracy. To improve the lattice-light-shift uncertainty, the cooling and trapping lasers' frequency stability is optimized, and the atom's signal stability is enhanced. A ring-cavity Ti:sapphire laser is locked to the optical frequency comb, which is referenced to a 578 nm ultra-stable laser, and the beat note's stability is on the order of 10−16. Using a 10 cm Fabry–Pérot cavity referenced to the Ti:sapphire laser, the optical frequency stability is transferred to the 399 nm cooling laser, creating favorable conditions for evaluating the lattice-light-shift accurately. We reevaluate lattice-light-shift in our 171Yb optical lattice clock with an uncertainty of 8.1 × 10−18, which is an order lower than our previous result, and the magic frequency is determined to be 394 798 266.6(1.3) MHz.
Quantum technologies are nowadays emerging as enabling tools for practical applications, such as quantum sensing, quantum computing and quantum metrology. Lasers play a central role in many of these technological platforms, e.g. for atomic clocks, ion-based or neutral atom-based quantum computers or atom interferometers. Here we present a complete laser system to cool, trap and control strontium atoms in an optical lattice or in tweezer arrays. A sub-Hz linewidth master laser, locked to a high-finesse optical cavity provides the frequency reference for an ultra-low noise comb. The rack-mounted laser system consists of all cooling, repumping, and clock lasers stabilized to the optical frequency comb. Each of the involved laser frequencies can therefore be tuned and mapped in the frequency domain with a high degree of stability. The system is controlled via a software interface, allowing to operate the cold-atom-based physics package autonomously. The system is tailored for the operation of 88Sr or 87Sr optical lattice clocks, or for quantum computing applications, but other sub-Hz lasers could be obtained by phase locking additional clock laser frequencies to the ultra-stable comb, enabling convenient and accurate optical frequency ratio measurements. The laser system architecture and the relevant characterization measurements will be presented, proposing some user-cases such as quantum computing and atom interferometry on strontium atoms. This represents a technological leap for quantum optics, allowing to explore further applications of quantum sensors outside a traditional lab.