Orders of Magnitude Improved Cyclotron-Mode Cooling for Nondestructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons
B. M. Latacz, M. Fleck, J. I. Jäger, G. Umbrazunas, B. P. Arndt, Stefan Erlewein, E. Wursten, J. A. Devlin, P. Micke, F. Abbass, D. Schweitzer, M. Wiesinger, C. Will, H. Yildiz, K. Blaum, Y. Matsuda, Andreas H. Mooser, C. Ospelkaus, C. Smorra, A. Sótér, W. Quint, J. Walz, Y. Yamazaki, S. Ulmer
We demonstrate efficient subthermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures T_{+}=E_{+}/k_{B} below 200 mK in preparation times shorter than 500 s. This corresponds to the fastest resistive single-particle cyclotron cooling to subthermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error rate <0.000 023, more than 3 orders of magnitude better than in previous best experiments. This method has enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter and antimatter symmetry, high-precision mass spectrometry, and measurements of electron g factors bound to highly charged ions that test quantum electrodynamics and establish standards for magnetometry.
We demonstrate efficient subthermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures T_{+}=E_{+}/k_{B} below 200 mK in preparation times shorter than 500 s. This corresponds to the fastest resistive single-particle cyclotron cooling to subthermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error rate <0.000 023, more than 3 orders of magnitude better than in previous best experiments. This method has enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter and antimatter symmetry, high-precision mass spectrometry, and measurements of electron g factors bound to highly charged ions that test quantum electrodynamics and establish standards for magnetometry.
Coherent quantum transition spectroscopy is a powerful tool in metrology1, quantum information processing2, magnetometry3 and precision tests of the standard model4. It was applied with great success in proton and deuteron magnetic moment measurements5, which culminated in maser spectroscopy with sub-parts-per-trillion resolution6 and many other experiments at the forefront of physics7. All of these experiments were performed on macroscopic ensembles of particles, whereas the coherent spectroscopy of a ‘free’ single nuclear spin has, to our knowledge, never been reported before. Here we demonstrate coherent quantum transition spectroscopy of the spin of a single antiproton stored in a cryogenic Penning-trap system. We apply a multi-trap technique8, detect the antiproton spin state using the continuous Stern–Gerlach effect9 and transport the particle to the homogeneous magnetic field of a precision trap (PT). Here we induce the coherent dynamics and analyse the result by quantum-projection measurements in the analysis trap (AT)10. We observe, for the first time, Rabi oscillations of an antiproton spin and achieve in time-series measurements spin-inversion probabilities greater than 80% at spin coherence times of about 50 s. Scans of single-particle spin resonances show inversions greater than 70%, at transition linewidths 16 times narrower than in previous measurements8, limited by cyclotron frequency measurement decoherence. This achievement marks a notable step towards at least tenfold improved tests of matter/antimatter symmetry using proton and antiproton magnetic moments. Coherent quantum transition spectroscopy of the spin of a single antiproton is reported, demonstrating Rabi oscillations of the spin and enabling improved measurement of matter/antimatter symmetry using proton and antiproton magnetic moments.
Abstract Efficient cooling of trapped charged particles is essential to many fundamental physics experiments 1,2 , to high-precision metrology 3,4 and to quantum technology 5,6 . Until now, sympathetic cooling has required close-range Coulomb interactions 7,8 , but there has been a sustained desire to bring laser-cooling techniques to particles in macroscopically separated traps 5,9,10 , extending quantum control techniques to previously inaccessible particles such as highly charged ions, molecular ions and antimatter. Here we demonstrate sympathetic cooling of a single proton using laser-cooled Be + ions in spatially separated Penning traps. The traps are connected by a superconducting LC circuit that enables energy exchange over a distance of 9 cm. We also demonstrate the cooling of a resonant mode of a macroscopic LC circuit with laser-cooled ions and sympathetic cooling of an individually trapped proton, reaching temperatures far below the environmental temperature. Notably, as this technique uses only image–current interactions, it can be easily applied to an experiment with antiprotons 1 , facilitating improved precision in matter–antimatter comparisons 11 and dark matter searches 12,13 .
High precision comparisons of the proton and antiproton g-factor enable stringent tests of CPT symmetry in the baryonic sector. However, current measurement routines suffer from long preparation times and high particle temperatures, which complicate the increase of the precision beyond the parts per billion regime. As a solution, new sympathetic cooling schemes based on co-trapped laser-cooled ions may be used to cool (anti-)protons to the ground state of motion and to significantly decrease particle preparation times. In addition, motional coupling to an auxiliary ion in a double-well potential can be used for the implementation of new readout schemes based on quantum logic spectroscopy for the spin-state of the (anti-)protons. This thesis describes a cryogenic Penning trap system for ground state cooling of single 9Be+ ions, which represents the latest development of the BASE experiment in Hannover towards the implementation of sympathetic cooling schemes and quantum logic spectroscopy of single (anti-)protons. Furthermore, the setup and implementation of lasers systems at 313nm for Doppler cooling, repumping and Raman interactions are described. To this end, an optical platform for laser beam delivery to the vacuum system and an optical phase-locked loop for the stabilization of the relative phase of two lasers at 313 nm are presented. In this work, the laser systems are used for measurements of the optical resonance frequencies for cooling, probing and repumping of 9Be+ ions. In addition, stimulated Raman transitions are demonstrated using two phase-locked lasers at 313nm. In the following, this technique is used for high-precision measurements of the qubit frequency and the magnetic field, as well as themometry measurements with 9Be+ ions. The temperature of the ions after Doppler cooling is measured as a function of the cooling laser parameters and a minimal axial mode temperature of 1.77(10) mK is obtained. The results of this thesis pave the way for sideband spectroscopy and ground state cooling of single 9Be+ ions in Penning traps, which is an essential prerequisite for sympathetic ground state cooling of single (anti-)protons and the application of quantum logic spectroscopy to (anti-)proton g-factor measurements in the future.
A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.
Fock states of a oneelectron cyclotron oscillator have been produced and observed nondestructively The states are longlived because spontaneous emission is inhib ited by a factor of using the modied radiation eld of a cylindrical Penning trap Direct nondestructive observation is achieved with a magnetic gradient that is ten times larger than previously possible allowing the states to be resolved with high signaltonoise ratio Quantum jumps up to the n cyclotron level have been observed The potential line broadening from the increased magnetic cou pling is avoided because we have lowered the temperature to which electrons can be cooled by nearly two orders of magnitude to as low as \t mK This is the rst time a trapped elementary particle has been cooled below K At these low temperatures the cyclotron oscillator is completely cooled to its ground state Detection of the electron signal is made possible by a lowpower transistor that was developed in collaboration with condensedmatter colleagues Applications include