Field-inhomogeneity-induced relaxation of atomic spins confined in vapor cells with depolarizing walls is studied. In contrast to nuclear spins, such as noble-gas spins, which experience minimal polarization loss at cell walls, atomic spins in uncoated cells undergo randomization at the boundaries. This distinct boundary condition results in a varied dependence of the relaxation rate on the field gradient. By solving the Bloch-Torrey equation under fully depolarizing boundary conditions, we illustrate that the relaxation rate induced by field inhomogeneity is more pronounced for spins with a smaller original relaxation rate (in the absence of the inhomogeneous field). We establish an upper limit for the relaxation rate through calculations in the perturbation regime. Moreover, we connect it to the spin-exchange-relaxation-free magnetometers, demonstrating that its linewidth is most sensitive to inhomogeneous fields along the magnetometer's sensitive axis. Our theoretical result agrees with the experimental data for cells subjected to small pump power. A deviation in high input-power scenarios arises from pump field attenuation, resulting in a nonuniformly distributed light shift that behaves like an inhomogeneous magnetic field.
Field-inhomogeneity-induced relaxation of atomic spins confined in vapor cells with depolarizing walls is studied. In contrast to nuclear spins, such as noble-gas spins, which experience minimal polarization loss at cell walls, atomic spins in uncoated cells undergo randomization at the boundaries. This distinct boundary condition results in a varied dependence of the relaxation rate on the field gradient. By solving the Bloch-Torrey equation under fully depolarizing boundary conditions, we illustrate that the relaxation rate induced by field inhomogeneity is more pronounced for spins with a smaller original relaxation rate (in the absence of the inhomogeneous field). We establish an upper limit for the relaxation rate through calculations in the perturbation regime. Moreover, we connect it to the spin-exchange-relaxation-free magnetometers, demonstrating that its linewidth is most sensitive to inhomogeneous fields along the magnetometer's sensitive axis. Our theoretical result agrees with the experimental data for cells subjected to small pump power. A deviation in high input-power scenarios arises from pump field attenuation, resulting in a nonuniformly distributed light shift that behaves like an inhomogeneous magnetic field.
The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.
In this work, a sensitivity of the rate of relaxation of ground-state atomic coherences to magnetic-field inhomogeneities is studied. Such coherences give rise to many interesting phenomena in light-atom interactions, and their lifetimes are a limiting factor for achieving better sensitivity, resolution, or contrast in many applications. For atoms contained in a vapor cell, some of the coherence-relaxation mechanisms are related to magnetic-field inhomogeneities. We present a simple model describing relaxation due to such inhomogeneities in a buffer-gas-free antirelaxation-coated cell. A relation is given between relaxation rate and magnetic-field inhomogeneities including the dependence on cell size and atomic species. Experimental results, which confirm predictions of the model, are presented. Different regimes, in which the relaxation rate is equally sensitive to the gradients in any direction and in which it is insensitive to gradients transverse to the bias magnetic field, are predicted and demonstrated experimentally.
In atomic vapor cells, atoms collide with the inner surface, causing their spin to randomize on the walls. This wall-depolarizing effect can be diffusive and it becomes more pronounced in smaller vapor cells under high temperatures. In this work we investigate the polarization of optically pumped alkali-metal atoms in a millimeter-sized cell heated to $150{\phantom{\rule{0.16em}{0ex}}}^{\ensuremath{\circ}}\text{C}$. We consider two extreme boundary conditions, fully depolarizing and nondepolarizing boundaries, and we provide an analytical estimation of the polarization difference between them. In the nondepolarizing case, the pump beam's absorption is proportional to the average atomic polarization. However, for fully depolarizing walls, the absorption peak may correspond to a polarization minimum. To mitigate the wall effect, we propose reducing the pump beam's diameter while maintaining the pump power to prevent illumination of the cell wall and increase the pump intensity in the central area. This is crucial for compact vapor-cell devices where the laser frequency cannot be detuned since it is locked to the absorption peaks. Additionally, we analyze the wall-depolarizing effect on the performance of an alkali-metal atomic magnetometer operating in the spin-exchange relaxation-free regime. We show that the signal strength is highly limited by wall collisions and we provide an upper bound for it.
In spin-exchange-relaxation-free (SERF) atomic magnetometers (AMs), the attenuation of circularly polarized pump beam introduces spatial-dependent artificial magnetic fields in atomic spin polarization and light shift. In general, such a spatial-dependent effective magnetic field, especially prevalent in single-cell magnetometer arrays, cannot be uniformly compensated over the entire excitation region, resulting in a complex distributed compensation mask effect. In addition, any external effective-field-compensation methods inevitably complicate the final analysis of the unknown magnetic field measured. Here, we report a new excitation scheme that can substantially suppress spatial nonuniformity due to pump beam attenuation. Using counter-propagating pump beams with symmetrically red- and blue-detuning-paired frequencies, we demonstrate a significant reduction of spatial inhomogeneity in atomic spin polarization and light shift in comparison with the usual single-frequency unidirection and counter-propagating pump schemes. Employing this red-/blue-detuning-paired pump scheme, we construct a single-cell, four-channel SERF magnetometer array with high spatial homogeneity. We demonstrate ~10-fT/Hz1/2sensitivity in the 5–45-Hz band for all four channels, with a gradient sensitivity of 2 fT/Hz1/21/2/cm in the same band. This new scheme enables the development of single-vapor-cell, high-uniformity multichannel magnetic field mapping devices with potential applications in magnetoencephalography (MEG) and magnetocardiography (MCG), or in searching for exotic spin-dependent interactions.
Atomic spin relaxation in a vapor cell, which can be characterized by the magnetic resonance linewidth (MRL), is an important parameter that eventually determines the sensitivity of an atomic magnetometer. In this paper, we have extensively studied how the pump intensity affects the spin relaxation. The experiment is performed with a cesium vapor cell, and the influence of the pump intensity on MRL is measured at room temperature at zero-field resonance. A simple model with five atomic levels of a Λ-like configuration is discussed theoretically, which can be used to represent the experimental process approximately, and the experimental results can be explained to some extent. Both the experimental and the theoretical results show a nonlinear broadening of the MRL when the pump intensity is increasing. The work helps to understand the mechanism of pump induced atomic spin relaxation in the atomic magnetometers.
Nowadays, quantum sensor research is a very interesting and popular topic. High-sensitivity magnetic field measurements using quantum sensors have evolved into the most sensitive magnetic field sensor category today with the invention of atomic magnetometers operating in the spin-exchange relaxation-free (SERF) regime. This letter was prepared to investigate the magnetic field sensitivity changes depending on the buffer gas, temperature, and laser intensity using indigenously produced atomic vapor cells. In addition, the aim was to determine the optimum operating conditions of the atomic magnetometer operating in the SERF regime. As a result, the resonance linewidth and signal-to-noise ratio were measured, and the minimum detectable magnetic field was calculated. According to the obtained results, the lowest magnetic field for Cells I–III was measured as 5.12, 4.21, and 4.81 pT, respectively. The lowest magnetic field of all conditions was obtained in vapor cell (Cell-II) at 100 °C with 5 mW laser intensity. As a result, it has been experimentally proven that under the same conditions, increasing the buffer gas pressure in vapor cells can narrow the resonance linewidth, and the magnetic field sensitivity can be improved by increasing the laser intensity applied to the vapor cells.