arXiv:2403.02328 · Physical Review Research

Strong thermomechanical noise squeezing stabilized by feedback

Aida Mashaal, Lucio Stefan, Andrea Ranfagni, Letizia Catalini, Ilia Chernobrovkin, Thibault Capelle, Eric Langman, Albert Schließer

Published Mar 17, 2025• 9 citations
arXivHTMLPDF

Abstract

Squeezing the quadrature noise of a harmonic oscillator enhances its sensitivity. Stabilization of the antisqueezed quadrature can overcome the 3 dB squeezing limit by parametric modulation. Here, we apply this method to soft-clamped membrane resonators, which hold promise for both classical and quantum sensing applications. We compare piezoelectric and capacitive parametric modulation and observe thermomechanical squeezing by up to 17 and 21 dB, respectively. Finally, we provide a full quantum theory of combining this approach with quantum-limited motion measurement. We conclude that quantum squeezing is feasible at moderate cryogenic temperatures and realistic device parameters.

DOI
10.1103/physrevresearch.7.l012071

Related papers

Deep feedback-stabilized parametric squeezing in an opto-electromechanical system

Menno Poot, King Yan Fong, Hong X. Tang

Using a stabilizing quadrature-feedback scheme the thermal motion of an on-chip opto-electromechanical resonator is squeezed far beyond the limit of classical parametric squeezing. It is shown that feedback on the Y quadrature by itself can already squeeze the thermal motion of the resonator, but the maximum achievable squeezing level is limited by the imprecision noise. By combining the feedback and parametric pumping a record of 15.1 dB of classical noise squeezing is demonstrated. This not only largely exceeds the 3 dB limit for regular squeezing, but is also deeper than ever can be achieved with feedback cooling. The detector-resonator interaction is analyzed within the semi-classical framework and it is shown that using this feedback-stabilized parametric pumping technique true quantum-squeezed states can be prepared when the resonator starts off close to its ground state, and that the ultimate amount of squeezing depends on the minimum detuning that can be achieved.

New Journal of Physics•Apr 27, 2015•25 citations

Feedback-Enhanced Parametric Squeezing of Mechanical Motion

Andrea Vinante, P. Falferi

We present a single-quadrature feedback scheme able to overcome the conventional 3 dB limit on parametric squeezing. The method is experimentally demonstrated in a micromechanical system based on a cantilever with a magnetic tip. The cantilever is detected at low temperature by a SQUID susceptometer, while parametric pumping is obtained by modulating the magnetic field gradient at twice the cantilever frequency. A maximum squeezing of 11.5 dB and 11.3 dB is observed, respectively, in the response to a sinusoidal test signal and in the thermomechanical noise. So far, the maximum squeezing factor is limited only by the maximum achievable parametric modulation. The proposed technique might be used to squeeze one quadrature of a mechanical resonator below the quantum noise level, even without the need for a quantum limited detector.

arXiv:1309.3121•Physical Review Letters•Nov 13, 2013•64 citations

Strong Thermomechanical Squeezing via Weak Measurement

Alex Szorkovszky, George A. Brawley, Andrew C. Doherty +1 more

We experimentally surpass the 3 dB limit to steady-state parametric squeezing of a mechanical oscillator. The localization of an atomic force microscope cantilever, achieved by optimal estimation, is enhanced by up to 6.2 dB in one position quadrature when a detuned parametric drive is used. This squeezing is, in principle, limited only by the oscillator Q factor. Used on low temperature, high frequency oscillators, this technique provides a pathway to achieve robust quantum squeezing below the zero-point motion. Broadly, our results demonstrate that control systems engineering can overcome well established limits in applications of nonlinear processes. Conversely, by localizing the mechanical position to better than the measurement precision of our apparatus, they demonstrate the usefulness of mechanical nonlinearities in control applications.

arXiv:1210.1657•Physical Review Letters•May 2, 2013•117 citations

Strong quantum squeezing of mechanical resonator via parametric amplification and coherent feedback

Xiang You, Zongyang Li, Yongmin Li

A scheme to achieve strong quantum squeezing of a mechanical resonator in a membrane-in-the-middle optomechanical system is developed. To this end, simultaneous linear and nonlinear coupling between the mechanical resonator and the cavity modes is applied. A two-tone driving light field, comprising unequal red-detuned and blue-detuned sidebands, helps in generating a coherent feedback force through the linear coupling with the membrane resonator. Another driving light field with its amplitude modulated at twice the mechanical frequency drives the mechanical parametric amplification through a second-order coupling with the resonator. The combined effect produces strong quantum squeezing of the mechanical state. The proposed scheme is quite robust to excess second-order coupling observed in coherent feedback operations and can suppress the fluctuations in the mechanical quadrature to far below the zero point and achieve strong squeezing (greater than 10 dB) for realistic parameters.

Physical Review A•Dec 8, 2017•22 citations

Mechanical Squeezing via Parametric Amplification and Weak Measurement

Alex Szorkovszky, Andrew C. Doherty, Glen I. Harris +1 more

Nonlinear forces allow motion of a mechanical oscillator to be squeezed below the zero-point motion. Of existing methods, mechanical parametric amplification is relatively accessible, but previously thought to be limited to 3 dB of squeezing in the steady state. We consider the effect of applying continuous weak measurement and feedback to this system. If the parametric drive is optimally detuned from resonance, correlations between the quadratures of motion allow unlimited steady-state squeezing. Compared to backaction evasion, we demonstrate that the measurement strength, temperature and efficiency requirements for quantum squeezing are significantly relaxed.

arXiv:1107.1294•Physical Review Letters•Nov 15, 2011•174 citations

Fast quantum squeezing of a nanomechanical oscillator with an inverted potential

Oscar Schmitt Kremer, Lorenzo Dania, Lukas Novotny +1 more

Nonclassical states of nano- and micro-mechanical motion enable measurements beyond the standard quantum limit and constitute a key resource for quantum sensing and metrology. The most strongly squeezed mechanical states to date have been generated with electromechanical platforms under cryogenic refrigeration and using reservoir engineering. To push mechanical systems deeper into the quantum-squeezed regime requires protocols that increase the rate at which squeezing is generated to more strongly overcome the decoherence rate at which state purity is lost. Here, we squeeze the 800 kHz libration mode of a silica nanoparticle optically levitated in vacuum at room temperature. We expose our mechanical oscillator to an optically generated inverted potential, where the squeezing operation proceeds at an exponentially accelerated rate. We reach a squeezed quadrature variance 11 dB below the vacuum fluctuations within 250 ns. Our protocol establishes a new paradigm for generating quantum squeezing of mechanical motion and offers a platform for quantum-enhanced sensing with massive oscillators.

quant-pharXiv:2609.12833•Sep 14, 2026•4 citations
Squeezing the quadrature noise of a harmonic oscillator enhances its sensitivity. Stabilization of the antisqueezed quadrature can overcome the 3 dB squeezing limit by parametric modulation. Here, we apply this method to soft-clamped membrane resonators, which hold promise for both classical and quantum sensing applications. We compare piezoelectric and capacitive parametric modulation and observe thermomechanical squeezing by up to 17 and 21 dB, respectively. Finally, we provide a full quantum theory of combining this approach with quantum-limited motion measurement. We conclude that quantum squeezing is feasible at moderate cryogenic temperatures and realistic device parameters.
Using a stabilizing quadrature-feedback scheme the thermal motion of an on-chip opto-electromechanical resonator is squeezed far beyond the limit of classical parametric squeezing. It is shown that feedback on the Y quadrature by itself can already squeeze the thermal motion of the resonator, but the maximum achievable squeezing level is limited by the imprecision noise. By combining the feedback and parametric pumping a record of 15.1 dB of classical noise squeezing is demonstrated. This not only largely exceeds the 3 dB limit for regular squeezing, but is also deeper than ever can be achieved with feedback cooling. The detector-resonator interaction is analyzed within the semi-classical framework and it is shown that using this feedback-stabilized parametric pumping technique true quantum-squeezed states can be prepared when the resonator starts off close to its ground state, and that the ultimate amount of squeezing depends on the minimum detuning that can be achieved.
We present a single-quadrature feedback scheme able to overcome the conventional 3 dB limit on parametric squeezing. The method is experimentally demonstrated in a micromechanical system based on a cantilever with a magnetic tip. The cantilever is detected at low temperature by a SQUID susceptometer, while parametric pumping is obtained by modulating the magnetic field gradient at twice the cantilever frequency. A maximum squeezing of 11.5 dB and 11.3 dB is observed, respectively, in the response to a sinusoidal test signal and in the thermomechanical noise. So far, the maximum squeezing factor is limited only by the maximum achievable parametric modulation. The proposed technique might be used to squeeze one quadrature of a mechanical resonator below the quantum noise level, even without the need for a quantum limited detector.
We experimentally surpass the 3 dB limit to steady-state parametric squeezing of a mechanical oscillator. The localization of an atomic force microscope cantilever, achieved by optimal estimation, is enhanced by up to 6.2 dB in one position quadrature when a detuned parametric drive is used. This squeezing is, in principle, limited only by the oscillator Q factor. Used on low temperature, high frequency oscillators, this technique provides a pathway to achieve robust quantum squeezing below the zero-point motion. Broadly, our results demonstrate that control systems engineering can overcome well established limits in applications of nonlinear processes. Conversely, by localizing the mechanical position to better than the measurement precision of our apparatus, they demonstrate the usefulness of mechanical nonlinearities in control applications.
A scheme to achieve strong quantum squeezing of a mechanical resonator in a membrane-in-the-middle optomechanical system is developed. To this end, simultaneous linear and nonlinear coupling between the mechanical resonator and the cavity modes is applied. A two-tone driving light field, comprising unequal red-detuned and blue-detuned sidebands, helps in generating a coherent feedback force through the linear coupling with the membrane resonator. Another driving light field with its amplitude modulated at twice the mechanical frequency drives the mechanical parametric amplification through a second-order coupling with the resonator. The combined effect produces strong quantum squeezing of the mechanical state. The proposed scheme is quite robust to excess second-order coupling observed in coherent feedback operations and can suppress the fluctuations in the mechanical quadrature to far below the zero point and achieve strong squeezing (greater than 10 dB) for realistic parameters.
Nonlinear forces allow motion of a mechanical oscillator to be squeezed below the zero-point motion. Of existing methods, mechanical parametric amplification is relatively accessible, but previously thought to be limited to 3 dB of squeezing in the steady state. We consider the effect of applying continuous weak measurement and feedback to this system. If the parametric drive is optimally detuned from resonance, correlations between the quadratures of motion allow unlimited steady-state squeezing. Compared to backaction evasion, we demonstrate that the measurement strength, temperature and efficiency requirements for quantum squeezing are significantly relaxed.
Nonclassical states of nano- and micro-mechanical motion enable measurements beyond the standard quantum limit and constitute a key resource for quantum sensing and metrology. The most strongly squeezed mechanical states to date have been generated with electromechanical platforms under cryogenic refrigeration and using reservoir engineering. To push mechanical systems deeper into the quantum-squeezed regime requires protocols that increase the rate at which squeezing is generated to more strongly overcome the decoherence rate at which state purity is lost. Here, we squeeze the 800 kHz libration mode of a silica nanoparticle optically levitated in vacuum at room temperature. We expose our mechanical oscillator to an optically generated inverted potential, where the squeezing operation proceeds at an exponentially accelerated rate. We reach a squeezed quadrature variance 11 dB below the vacuum fluctuations within 250 ns. Our protocol establishes a new paradigm for generating quantum squeezing of mechanical motion and offers a platform for quantum-enhanced sensing with massive oscillators.