Hong–Ou–Mandel (HOM) interferometry has emerged as a valuable means for quantum sensing applications, particularly in measuring physical parameters that influence the relative optical delay between photon pairs. Unlike classical techniques, HOM-based quantum sensors offer higher resolution due to the intrinsic dispersion cancellation property of correlated photon pairs. Due to the use of single photons, HOM-based quantum sensors typically involve a large integration time to acquire the signal and subsequent post-processing for high-resolution measurements, restricting their use for real-time operations. Based on our understanding of the relationship between measurement resolution and the gain medium length that produces photon pairs, we report here on the development of an HOM-based quantum sensor for high-precision group index measurements. Using a 1 mm long periodically poled KTP (PPKTP) crystal for photon-pair generation, we have measured the group index with a precision of ∼6.75×10−6 per centimeter of sample length at an integration time of 100 ms, surpassing the previous reports by 400%. Typically, the measurement range reduces with the increase in the resolution. However, using a novel scheme compensating photon delay due to group index changes stepwise with an optical delay stage, we have measured the group index variation of PPKTP crystal over a range of 3.5 × 10−3 for a temperature change from 25 to 200 °C, corresponding to an optical delay adjustment of ∼200 μm while maintaining the same precision (∼6.75×10−6 per centimeter of sample length). The current results establish the usefulness of HOM-interferometer-based quantum sensors for fast, precise, and long-range measurements in various applications, including quantum optical coherence tomography.
Hong–Ou–Mandel (HOM) interferometry has emerged as a valuable means for quantum sensing applications, particularly in measuring physical parameters that influence the relative optical delay between photon pairs. Unlike classical techniques, HOM-based quantum sensors offer higher resolution due to the intrinsic dispersion cancellation property of correlated photon pairs. Due to the use of single photons, HOM-based quantum sensors typically involve a large integration time to acquire the signal and subsequent post-processing for high-resolution measurements, restricting their use for real-time operations. Based on our understanding of the relationship between measurement resolution and the gain medium length that produces photon pairs, we report here on the development of an HOM-based quantum sensor for high-precision group index measurements. Using a 1 mm long periodically poled KTP (PPKTP) crystal for photon-pair generation, we have measured the group index with a precision of ∼6.75×10−6 per centimeter of sample length at an integration time of 100 ms, surpassing the previous reports by 400%. Typically, the measurement range reduces with the increase in the resolution. However, using a novel scheme compensating photon delay due to group index changes stepwise with an optical delay stage, we have measured the group index variation of PPKTP crystal over a range of 3.5 × 10−3 for a temperature change from 25 to 200 °C, corresponding to an optical delay adjustment of ∼200 μm while maintaining the same precision (∼6.75×10−6 per centimeter of sample length). The current results establish the usefulness of HOM-interferometer-based quantum sensors for fast, precise, and long-range measurements in various applications, including quantum optical coherence tomography.
Abstract Hong–Ou–Mandel (HOM) interference, bunching of two indistinguishable photons on a balanced beam‐splitter, has emerged as a promising tool for quantum sensing. There is a need for wide spectral‐bandwidth photon pairs (for high‐resolution sensing) with high brightness (for fast sensing). Here, the generation of photon‐pairs with flexible spectral‐bandwidth even using single‐frequency, continuous‐wave diode laser enabling high‐precision, real‐time sensing is showed. Using 1‐mm‐long periodically‐poled KTP crystal, degenerate, photon‐pairs with spectral‐bandwidth of 163.42±1.68 nm are produced resulting in a HOM‐dip width of 4.01±0.04 m to measure a displacement of 60 nm, and sufficiently high brightness to enable the measurement of vibrations with amplitude of 205 ± 0.75 nm and frequency of 8 Hz. Fisher‐information (FI) and maximum likelihood estimation enables optical delay measurements as small as 4.97 nm with precision (Cramér–Rao bound) and accuracy of 0.89 and 0.54 nm, respectively, therefore showing HOM sensing capability for real‐time, precision‐augmented, in‐field quantum sensing applications.
Hong-Ou-Mandel (HOM) interferometry enables delay estimation at the quantum precision limit but is traditionally constrained to path differences within the coherence time of the interfering photons. Here, we demonstrate single-measurement path-delay sensing at the measurement Cramer-Rao bound using spectrally resolved HOM interference, thereby removing the conventional dynamic-range limitation imposed by the photon coherence window, with no scanning required for calibration. By extracting delay information from the spectral interference fringes of spectrally entangled photon pairs, we retain near-optimal sensitivity over an operational range exceeding the photon coherence time by over two orders of magnitude. Using one million detected photon pairs, we achieve a time-delay precision of 20 attosecond (6 nm), while real-time operation (at 1 Hz) yields 330 attosecond (100 nm) precision. Because the estimator relies on fringe periodicity rather than absolute coincidence rates, the method is intrinsically robust to photon losses and variations in interference visibility, eliminating the need for recalibration. As a practical demonstration, we measure the thickness of a 300 um transmissive target with nanometer-scale precision. These results mark a significant step towards deploying quantum-limited measurements in real-world sensing applications using HOM interferometry.
Two-photon interference, commonly known as Hong-Ou-Mandel (HOM) interference [1] , has attracted a great deal of interest in quantum sensing, including the precision timing measurements [2] and quantum optical coherence tomography [3] . While the dip of the HOM interference is the direct measure of the purity of the single-photon, the width of the HOM dip relates to the coherence time of the interfering photons. The broad consensus for using the HOM interferometer for sensing application remained the HOM dip width as the limiting factor for the precision measurements. As a consequence, the ultra-broadband photon sources have long been hailed as a vital prerequisite for ultra-precise HOM interferometry. Here, we have studied the variation in the width of the HOM dip with the crystal length for the continuous-wave pump laser and measured the HOM dip as low as 8.2 ± 0.2 µm corresponding to the spectral width of the single-photon source of 79.6±1.9 nm useful for sensitive sensing applications.
Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.
Quantum interference forces two indistinguishable input photons to depart a beamsplitter in the same (of two possible) spatial output modes; this is known as the Hong-Ou-Mandel (HOM) effect. It provides a quantitative way of measuring the distinguishability between two photons and also has been utilised to determine their relative temporal delays [1, 2]. HOM interferometry offers numerous advantages over its classical counterpart, most importantly it lacks any dependence on the phase of the photons and therefore can potentially provide reliable measurements in environments where the phase is unstable. To date there have been very few investigations on the precision that is achievable with HOM interferometry. Experiments with collinear geometries have yielded sensitivities as low as 0.1fs however these approaches are limited to measurements of birefringence and other polarisation dependent effects [3, 4], as the precision derives from the inherently stable shared path of the photon pairs. Typical non-shared path HOM interferometers exhibit resolution of roughly 1–3 fs (0.3–1 μm).
Interference has long been used for precision measurement of path-length changes. Since the advent of the laser, interference has become one of the most versatile tools in metrology. Specifically, ultra-short laser pulses allow unprecedented resolution in absolute length measurements. While ultra-short laser pulses lead to high resolution, for example in white-light interferometry, they are very susceptible to dispersion. \n \nQuantum resources have been proposed to overcome some of the problems related to distortions in the interferometric signal. For example, the Hong-Ou-Mandel (HOM) interferometer relies on frequency-entangled photon pairs and features automatic even-order dispersion cancellation and high interference visibility resilient to unbalanced loss. Quantum-OCT is a technique based on HOM interferometry, that promises to overcome Optical Coherence Tomography (OCT) a classical imaging technique based on low coherence light. Furthermore, straightforward modifications of the HOM interferometer can display several different interferometric signals, including the HOM peak, quantum beating, and phase super-resolution. However, the quantum resources required are hard to produce and dim, leading to long integration times and single-photon counting. \n \nIn this thesis, we introduce the theory behind Chirped-Pulse Interferometry (CPI), a new technique that combines all the advantages of Q-OCT, including even-order dispersion cancellation, but without the need for any quantum resources. We then experimentally implement CPI and demonstrate all the important characteristics shared by the HOM interferometer, but at dramatically larger signal levels. We show how CPI can be used to measure dispersion cancelled axial profiles of an optical sample and show the improvement in resolution over white-light interferometry. Finally, we show that by modifying CPI in analogous ways to HOM, CPI can also be made to produce interferometric signal identical to the HOM peak, quantum beating, and phase super-resolution.