Ground-based interferometric gravitational-wave detectors are highly precise sensors for weak forces, limited in sensitivity across their detection band by quantum fluctuations of light. Current and future instruments address this limitation by injecting frequency-dependent squeezed vacuum into the detection port, utilizing narrow-band, low-loss optical filter cavities for optimal rotation of the squeezing ellipse at each signal frequency. This study introduces a scheme of such vacuum injection employing the principles of quantum teleportation which works the same as an arbitrary number of filter cavities without additional kilometer-scale infrastructure. We applied this scheme to a detuned signal-recycled Fabry-P\'erot--Michelson interferometer, which is the baseline design of the low-frequency detector within the Einstein Telescope xylophone detector. It is shown that our scheme achieves broadband suppression of quantum noise without requiring additional filter cavities or modifications to the core optics of the main interferometer.
Ground-based interferometric gravitational-wave detectors are highly precise sensors for weak forces, limited in sensitivity across their detection band by quantum fluctuations of light. Current and future instruments address this limitation by injecting frequency-dependent squeezed vacuum into the detection port, utilizing narrow-band, low-loss optical filter cavities for optimal rotation of the squeezing ellipse at each signal frequency. This study introduces a scheme of such vacuum injection employing the principles of quantum teleportation which works the same as an arbitrary number of filter cavities without additional kilometer-scale infrastructure. We applied this scheme to a detuned signal-recycled Fabry-P'erot--Michelson interferometer, which is the baseline design of the low-frequency detector within the Einstein Telescope xylophone detector. It is shown that our scheme achieves broadband suppression of quantum noise without requiring additional filter cavities or modifications to the core optics of the main interferometer.
The quantum noise in gravitational-wave detectors can be suppressed in a broadband by frequency-dependent squeezing. It usually requires one large scale filter cavity and even two, for example in the low frequency detector of Einstein Telescope, which is a detuned dual recycling Fabry-Perot Michelson interferometer. In this paper, we study the feasibility of replacing two filter cavities with a coupled-cavity, aiming to reduce the optical losses with less number of optics. It turns out this approach is only theoretically valid, however, the required parameters of the optics do not support practical implementation, which is consistent with the results in Jones [Implications of the quantum noise target for the Einstein Telescope infrastructure design, ]. Furthermore, we investigate the viability of utilizing Einstein-Podolsky-Rosen (EPR) squeezing to eliminate either one or two filter cavities in the Einstein Telescope. It turns out EPR squeezing would allow us to eliminate one filter cavity, and can potentially improve the detector sensitivity with the allowance of higher input squeezing level, benefiting from the longer length of the arm cavity which serves as one of the filter cavities for frequency-dependent squeezing. Published by the American Physical Society 2024
Employing the principle of quantum teleportation in gravitational-wave detectors provides a method to address technical challenges associated with implementing quantum filters for squeezed-light injection. A recent proposal [Phys. Rev. A 110, 022601] has shown that an arbitrary number of effective squeezing-angle rotations can be achieved by cascading quantum teleportation, yielding sensitivity equivalent to frequency-dependent prefiltering. A natural question is whether the teleportation-based protocol can also realize frequency-dependent postfiltering. In this work, we examine this possibility and show that, with perfect teleportation fidelity, postfiltering can be fully implemented. In practice, however, various imperfections make the sensitivity nearly equivalent to that of teleportation-based prefiltering. We apply this scheme to the low-frequency detector in the Einstein Telescope xylophone configuration and find that teleportation-based postfiltering could also be a candidate for the detector's design.
Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.
The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where interferometers are typically shot-noise limited, although the SQL might not be beaten in this case. We theoretically analyze the quantum noise of the signal-recycled laser interferometric gravitational-wave detector GEO600 with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We focus on the frequency range between 1 kHz and 10 kHz, where, although signal recycled, the detector is still shot-noise limited. It is found that the GEO600 detector with present design parameters will benefit from frequency dependent squeezed light. Assuming a squeezing strength of -6 dB in quantum noise variance, the interferometer will become thermal noise limited up to 4 kHz without further reduction of bandwidth. At higher frequencies the linear noise spectral density of GEO600 will still be dominated by shot-noise and improved by a factor of 10^{6dB/20dB}~2 according to the squeezing strength assumed. The interferometer might reach a strain sensitivity of 6x10^{-23} above 1 kHz (tunable) with a bandwidth of around 350 Hz. We propose a scheme to implement the desired frequency dependent squeezing by introducing an additional optical component to GEO600s signal-recycling cavity.
The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo, and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.
Broadband quantum noise reduction can be achieved in gravitational-wave detectors by injecting frequency-dependent squeezed light into the dark port of the interferometer. This frequency-dependent squeezing can be generated by combining squeezed light with external filter cavities. However, in future long baseline interferometers (LBIs), the filter cavity required to achieve the broadband squeezing has a low bandwidth---necessitating a very long cavity to mitigate the issue from optical loss. It has been shown recently that by taking advantage of Einstein-Podolsky-Rosen (EPR) entanglement in the squeezed light source, the interferometer can simultaneously act as a detector and a filter cavity. This is an attractive broadband squeezing scheme for LBIs because the length requirement for the filter cavity is naturally satisfied by the length of the interferometer arms. In this paper we present a systematic way of finding the working points for this broadband squeezing scheme in LBIs. We also show that in LBIs, the EPR scheme achieves nearly perfect ellipse rotation as compared to 4-km interferometers which have appreciable error around the intermediate frequency. Finally, we show that an approximation for the optomechanical coupling constant in the 4-km case can break down for longer baselines. These results are applicable to future detectors such as the 10-km Einstein Telescope and the 40-km Cosmic Explorer.