Abstract We simulate the dynamics of systems with multiple qubits coupled to a cavity in order to assess their potential for quantum metrology of a parameter in the open systems limit. The qubits and the cavity are both allowed to have losses and the system is studied under various coupling strength regimes. The focus is primarily on the coupling between the qubits using the quantum Fisher information as the measured parameter. Some results on estimating the qubit-cavity detuning parameter are also presented. We investigate the scaling of the uncertainty in the estimate of the qubit–cavity coupling with the number of qubits and for different initial states of the qubits that act as the quantum probe. As initial probe states, we consider Dicke states with varying excitation numbers, the GHZ state, and separable X -polarized states. It is shown that in the strong coupling regime, i.e. when the coupling between the qubits and the cavity is greater than the decay parameters of both the qubits and the cavity, Dicke states with a large excitation number can achieve the Heisenberg limit, with the precision scaling improving as the excitation number increases. A particularly intriguing finding of our study is that in the weak coupling regime, as well as in situations where either the qubit or cavity decay parameters exceed the coupling, the separable X -polarized state is the best in terms of scaling and exhibits strongly superlinear, and in some regimes near-quadratic, finite-size QFI scaling over the system sizes considered.
Abstract We simulate the dynamics of systems with multiple qubits coupled to a cavity in order to assess their potential for quantum metrology of a parameter in the open systems limit. The qubits and the cavity are both allowed to have losses and the system is studied under various coupling strength regimes. The focus is primarily on the coupling between the qubits using the quantum Fisher information as the measured parameter. Some results on estimating the qubit-cavity detuning parameter are also presented. We investigate the scaling of the uncertainty in the estimate of the qubit–cavity coupling with the number of qubits and for different initial states of the qubits that act as the quantum probe. As initial probe states, we consider Dicke states with varying excitation numbers, the GHZ state, and separable X -polarized states. It is shown that in the strong coupling regime, i.e. when the coupling between the qubits and the cavity is greater than the decay parameters of both the qubits and the cavity, Dicke states with a large excitation number can achieve the Heisenberg limit, with the precision scaling improving as the excitation number increases. A particularly intriguing finding of our study is that in the weak coupling regime, as well as in situations where either the qubit or cavity decay parameters exceed the coupling, the separable X -polarized state is the best in terms of scaling and exhibits strongly superlinear, and in some regimes near-quadratic, finite-size QFI scaling over the system sizes considered.
We address in detail the process of parameter estimation for an n-qubit system dissipating into a cavity in which the qubits are coupled to the single-mode cavity field via coupling constant g which should be estimated. In addition, the cavity field interacts with an external field considered as a set of continuum harmonic oscillators. We analyse the behaviour of the quantum Fisher information (QFI) for both weak and strong coupling regimes. In particular, we show that in strong coupling regime, the memory effects are dominant, leading to an oscillatory variation in the dynamics of the QFI and consequently information flowing from the environment to the quantum system. We show that when the number of the qubits or the coupling strength rises, the oscillations, signs of non-Markovian evolution of the QFI, increase. This indicates that in the strong-coupling regime, increasing the size of the system or the coupling strength remarkably enhances the reversed flow of information. Moreover, we find that it is possible to retard the QFI loss during the time evolution and therefore enhance the estimation of the parameter using a cavity with a larger decay rate factor. Furthermore, analysing the dynamics of the QFI and negativity of the probe state, we reveal a close relationship between the entanglement of probes and their capability for estimating the parameter. It is shown that in order to perform a better estimation of the parameter, we should avoid measuring when the entanglement between the probes is maximized.
Going beyond the standard quantum limit in noisy quantum metrology is an important and challenging task. Here we show how Dicke states can be used to surpass the standard quantum limit and achieve the Heisenberg limit in open quantum systems. The system we study has qubits symmetrically coupled to a resonator, and our objective is to estimate the coupling between the qubits and the resonator. The time-dependent quantum Fisher information with respect to the coupling is studied for this open quantum system where the same decay rates are assumed on all qubits. We show that when the system is initialized to a Dicke state with an optimal excitation number one can go beyond the standard quantum limit and achieve the Heisenberg limit even for finite values of the decays on the qubit and the resonator, particularly when the qubits and resonator are strongly coupled. We compare our results against the highly entangled GHZ state and a completely separable state and show that the GHZ state performs quite poorly, whereas under certain noise conditions the separable state is able to go beyond the standard quantum limit due to subsequent interactions with a resonator.
We investigate how photon loss and environmental memory affect probe selection and measurement sensitivity for estimating the dispersive coupling strength in a cavity qubit system. Using density operator and quantum state diffusion approaches, we examine the quantum Fisher information for representative separable and entangled initial states in Markovian and non Markovian regimes. The results show that closed system generator variance alone does not determine open system performance. The survival of parameter sensitive coherences and the influence of environmental memory also play important roles. Within the single photon preparations examined, a separable probe can outperform the entangled family considered. Comparisons of selected coherent and squeezed vacuum preparations at equal mean photon number further illustrate how photon number statistics and qubit preparation affect sensitivity. For the parameters studied, finite environmental memory can enhance and prolong sensitivity and yield nonzero QFI for a probe whose Markovian QFI vanishes. We also numerically identify a fixed Hermitian observable whose error propagation uncertainty remains close to the quantum Cramer Rao bound over a prescribed coupling interval in the Markovian regime. These findings clarify the interplay between probe preparation, environmental dynamics, and measurement choice in dispersive quantum metrology.
We study in this work the metrology precision of a probe system coupled to an ancillary qubit. Restricting the probe-qubit coupling along only one or two directions is found to be a sufficient criterion for the effective dynamical generator to achieve the Heisenberg limit in precision. Under the criterion, the quantum Fisher information (QFI) about the to-be-estimated parameter becomes the expectation value of mean square of the effective generator with respect to the initial state of the composite system. Our criterion is justified in two distinct systems. For a bosonic probe, QFI about the displacement estimation is found to be proportional to the mean excitation number of probe. It renders a counterintuitive result that quantum metrology sensitivity can be enhanced by increasing the temperature of the probe system. For a spin-ensemble probe, QFI about both rotation-phase and magnetic-field estimation exhibit a quadratic dependence on the probe-spin number. It is found that even when the spin-ensemble is prepared as a finite-temperature state, faraway from the so-called resource states, e.g., the squeezed state or the Greenberger-Horne-Zeilinger state, QFI can still manifest a Heisenberg scaling behavior.
Abstract Quantum metrology enables measurement sensitivities beyond classical limits by exploiting quantum resources. Among promising platforms, hybrid cavity–magnon systems—where microwave photons interact with collective spin excitations in magnetic materials—offer a versatile testbed for emerging quantum technologies. However, their performance hinges on precise knowledge of the cavity–magnon coupling strength. Here, we propose an experimentally feasible scheme to enhance the quantum estimation of this parameter by leveraging coherent feedback and parametric amplification. Using the Heisenberg–Langevin formalism, we linearize the system dynamics and compute both quantum (QFI) and classical Fisher information. Our analysis shows that optimal detuning, strong driving, and cryogenic temperatures below 0.1 K significantly improve estimation precision, while magnon dissipation and thermal noise degrade the QFI. Parametric amplification enhances precision when the gain and phase are optimally tuned, and coherent feedback yields even greater sensitivity at tailored phase shifts and reflectivities. Notably, their combination achieves the lowest estimation error and the highest robustness against thermal noise. Finally, we identify the cavity mode as the optimal probe, with homodyne detection nearly saturating the quantum limit under ideal conditions. These findings establish a robust pathway for high-precision, noise-resilient cavity–magnon coupling estimation.
Critical quantum metrology exploits the hypersensitivity of quantum systems near phase transitions to achieve enhanced precision in parameter estimation. While single-parameter estimation near critical points is well established, the simultaneous estimation of multiple parameters, which is essential for practical sensing applications, remains challenging. This difficulty arises from sloppiness, a phenomenon that typically renders the quantum Fisher information matrix (QFIM) singular or nearly singular. In this work, we demonstrate that multiparameter critical metrology is not only feasible but can also retain divergent precision scaling, provided one accepts a trade-off in the scaling exponent. Using the ground state of the single-cavity Dicke model (DM), we show that two Hamiltonian parameters can be simultaneously estimated with a scalar variance bound scaling as the square root of the critical parameter. This overcomes the inherent sloppiness by leveraging higher-order contributions to the QFIM. To recover the optimal quadratic scaling, we introduce the Dicke dimer (DD) with photon hopping. In this extended model, a triple point in the phase diagram enables the simultaneous closure of two excitation gaps, which effectively increases the rank of the QFIM and restores the ideal single-parameter scaling for specific parameter pairs. Furthermore, we extend our analysis to dissipative settings subject to photon loss. Finally, we establish a connection between the derived critical scalings and the fundamental state preparation time, providing a unified framework to operationally compare different sensing strategies. Our results demonstrate that critical quantum metrology can be made robust against dissipation and scalable to multiparameter scenarios, paving the way for practical quantum sensors operating near phase transitions.