Single-photon transitions are one of the key technologies for designing and operating very-long-baseline atom interferometers tailored for terrestrial gravitational-wave and dark-matter detection. Since such setups aim at the detection of relativistic and beyond-Standard-Model physics, the analysis of interferometric phases as well as of atomic diffraction must be performed to this precision and including these effects. In contrast, most treatments focused on idealized diffraction so far. Here, we study single-photon transitions, both magnetically-induced and direct ones, in gravity and Standard-Model extensions modeling dark matter as well as Einstein-equivalence-principle violations. We take into account relativistic effects like the coupling of internal to center-of-mass degrees of freedom, induced by the mass defect, as well as the gravitational redshift of the diffracting light pulse. To this end, we also include chirping of the light pulse required by terrestrial setups, as well as its associated modified momentum transfer for single-photon transitions.
Single-photon transitions are one of the key technologies for designing and operating very-long-baseline atom interferometers tailored for terrestrial gravitational-wave and dark-matter detection. Since such setups aim at the detection of relativistic and beyond-Standard-Model physics, the analysis of interferometric phases as well as of atomic diffraction must be performed to this precision and including these effects. In contrast, most treatments focused on idealized diffraction so far. Here, we study single-photon transitions, both magnetically-induced and direct ones, in gravity and Standard-Model extensions modeling dark matter as well as Einstein-equivalence-principle violations. We take into account relativistic effects like the coupling of internal to center-of-mass degrees of freedom, induced by the mass defect, as well as the gravitational redshift of the diffracting light pulse. To this end, we also include chirping of the light pulse required by terrestrial setups, as well as its associated modified momentum transfer for single-photon transitions.
Single-photon transitions are one of the key technologies for designing and operating very-long-baseline atom interferometers tailored for terrestrial gravitational-wave and dark-matter detection. Since such setups aim at the detection of relativistic and beyond-Standard-Model physics, the analysis of interferometric phases as well as of atomic diffraction must be performed to this precision and including these effects. In contrast, most treatments focused on idealized diffraction so far. Here, we study single-photon transitions, both magnetically induced and direct ones, in gravity and Standard-Model extensions modeling dark matter as well as Einstein-equivalence-principle violations. We take into account relativistic effects like the coupling of internal to center-of-mass degrees of freedom, induced by the mass defect, as well as the gravitational redshift of the diffracting light pulse. To this end, we also include chirping of the light pulse required by terrestrial setups, as well as its associated modified momentum transfer for single-photon transitions.
Single-photon transitions are one of the key technologies for designing and operating very-long-baseline atom interferometers tailored for terrestrial gravitational-wave and dark-matter detection. Since such setups aim at the detection of relativistic and beyond-Standard-Model physics, the analysis of interferometric phases as well as of atomic diffraction must be performed to this precision and including these effects. In contrast, most treatments focused on idealized diffraction so far. Here, we study single-photon transitions, both magnetically induced and direct ones, in gravity and Standard-Model extensions modeling dark matter as well as Einstein-equivalence-principle violations. We take into account relativistic effects like the coupling of internal to center-of-mass degrees of freedom, induced by the mass defect, as well as the gravitational redshift of the diffracting light pulse. To this end, we also include chirping of the light pulse required by terrestrial setups, as well as its associated modified momentum transfer for single-photon transitions.
Atom interferometers with long baselines are envisioned to complement the ongoing search for dark matter. They rely on atomic manipulation based on internal (clock) transitions or state-preserving atomic diffraction. Principally, dark matter can act on the internal as well as the external degrees of freedom to both of which atom interferometers are susceptible. We, therefore, study in this contribution the effects of dark matter on the internal atomic structure and the atom's motion. In particular, we show that the atomic transition frequency depends on the mean coupling and the differential coupling of the involved states to dark matter, scaling with the unperturbed atomic transition frequency and the Compton frequency, respectively. The differential coupling is only of relevance when internal states change, which makes detectors, e.g., based on single-photon transitions sensitive to both coupling parameters. For sensors generated by state-preserving diffraction mechanisms like Bragg diffraction, the mean coupling modifies only the motion of the atom as the dominant contribution. Finally, we compare both effects observed in terrestrial dark-matter detectors.
The search for a fundamental, self-consistent theoretical framework to cover phenomena over all energy scales is possibly the most challenging quest of contemporary physics. Approaches to reconcile quantum mechanics and general relativity entail the modification of their foundations such as the equivalence principle. This corner stone of general relativity is suspected to be violated in various scenarios and is therefore under close scrutiny. Experiments based on the manipulation of cold atoms are excellently suited to challenge its different facets. Freely falling atoms constitute ideal test masses for tests of the universality of free fall in interferometric setups. Moreover, the superposition of internal energy eigenstates provides the notion of a clock, which allows to perform tests of the gravitational redshift. Furthermore, as atom interferometers constitute outstanding phasemeters, they hold the promise to detect gravitational waves, another integral aspect of general relativity. In recent years, atom interferometers have developed into versatile sensors with excellent accuracy and stability, and allow to probe physics at the interface of quantum mechanics and general relativity without classical analog. In this thesis, various aspects regarding tests of general relativity with atom interferometry have been theoretically investigated. This includes the analysis of fundamental effects as well as feasibility studies of experimental configurations. The work is partially focussed on a space-borne mission scenario for a dedicated quantum test of the universality of free fall beyond state-of-the-art by dropping matter waves of different elements. To enable the target accuracy at the level of 10^(−17), a compensation scheme has been developed and discussed, mitigating the detrimental effects of imperfect test mass co-location upon release and relaxing the requirements on the source preparation by several orders of magnitude. In addition, it was demonstrated that the careful design of quantum degenerate sources is indispensable for these experiments, requiring tailored schemes to prepare miscible binary sources. The possibility to test the gravitational redshift with atom interferometers has also been examined in this thesis and connected to the ideas of clock interferometry. With the proof that closed light pulse atom interferometers without transitions between internal internal states are not sensitive to gravitational time dilation, an ongoing scientific debate has been resolved. Instead, certain configurations were shown to implement a quantum version of the special-relativistic twin paradox, for which an experiment has been proposed. Finally, requirements on atomic sources and atom optics for scenarios of gravitational wave detection on ground and in space have been investigated.
Abstract Light-pulse atom interferometers based on single-photon transitions are a promising tool for gravitational-wave detection in the mid-frequency band and the search for ultralight dark-matter fields. Here we present a novel measurement scheme that enables their use as freely falling clocks directly measuring relativistic time-dilation effects. The proposal is particularly timely because it can be implemented with no additional requirements in Fermilab’s MAGIS-100 experiment or even in the 10 m prototypes that are expected to start operating very soon. This will allow the unprecedented measurement of gravitational time dilation in a local experiment with freely falling atoms, which is beyond reach even for the best atomic-fountain clocks based on microwave transitions. The results are supported by a comprehensive treatment of relativistic effects in this kind of interferometer as well as a detailed analysis of the main systematic effects. Furthermore, the theoretical methods developed here constitute a valuable tool for modelling light-pulse atom interferometers based on single-photon transitions in general.
This cumulative thesis consists of four publications [1-4], presented as three contributions (I) - (III), where the second one (II) consists of the joint publications [2,3]. All publications were written during the author's research activities at the Institute of Quantum Physics under the supervision of Prof. Dr. W. P. Schleich. All of the presented publications consider light-matter interactions and their potential application in atom interferometry, a comparatively young and rapidly evolving technique. Atom interferometers find application in high-precision measurements, the determination of physical constants, the testing of fundamental physics, and the provision of gravimeters and gyroscopes. The advancement of technology and science has led to significant improvements in performance and the development of ambitious mobile and space-based devices. The recent success of several experiments has led to the proposal of further experiments with the aim of opening up new frontiers. However, the construction of future devices necessitates a decision regarding the employed diffraction mechanism and geometry, depending on the specific technical and scientific requirements. Furthermore, it is necessary to enhance the sensitivity of future devices. The contributions in this dissertation address these issues. The first contribution (I) focuses on the diffraction of atoms by laser pulses which can be employed to generate atom-optical diffraction elements like beam splitters and mirrors. These diffraction elements can be combined to construct atom interferometers, which have been successfully employed for precision measurements regarding fundamental physics as well as practical applications. The article presents a numerical comparison of two distinct diffraction mechanisms (Bragg and Raman) and diffraction geometries (single and double diffraction) in microgravity. It discusses the fundamental differences between the mechanisms and geometries with respect to the diffraction efficiency, taking into account the width of the initial wave function and the duration of the light pulse. Additionally, it explores the transition between the two diffraction geometries when starting from an atom initially at rest and increasing its momentum. The results may serve as a reference for experimentalists in selecting the most suitable configuration, based on their aims and requirements in the realization of more advanced atom interferometers. The second contribution (II) is a follow-up to the previous one, but focuses exclusively on a single diffraction type in microgravity, namely the so-called double Raman diffraction. In contrast to the previous article, where we only discussed single two-photon processes, we consider in this article a six-photon process, also known as third-order diffraction, as well as three subsequent two-photon processes, which both lead to the same amount of transferred momentum and can both be used to realize large-momentum transfer (LMT). We demonstrate that third-order double Raman diffraction is a viable and advantageous method for the diffraction of small momentum distributions like Bose-Einstein condensates (BECs) compared to a sequence of three two-photon processes. Furthermore, we show that third-order Raman pulses can be successfully applied to create higher-order Raman atom interferometers. Third-order diffraction can be perfectly combined with other LMT techniques and, moreover, allows for a reduction in the overall duration of the diffraction process and the complexity of the experimental set-up, as only two distinct laser frequencies are required. Moreover, we present a third-order Mach-Zehnder interferometer with spurious paths being disregarded. As demonstrated later on in [3], this interferometer generates optimal contrast and a substantial amplitude. The third contribution (III) extends the semi-classical λ-scheme of single Raman diffraction, as discussed in detail in contribution (I), into a fully quantized multi-atom multi-λ configuration with center-of-mass motion inside a cavity. Therefore, the incorporation of an internal structure allows for a more realistic modeling of the atoms, which is relevant for multi-photon interaction or cooling processes. We use for our analysis the framework of second quantization, i.e., we take into account the field-theoretical nature of the multi-particle atomic field as well as of the diffracting light field. We reduce this model with a Hamiltonian averaging theory applied to the atomic field operators and obtain an effective Hamiltonian, which determines the time evolution of the system. We demonstrate the efficiency of our model by the application of a typical initial state. Moreover, for a specific input state, we obtain the Hong-Ou-Mandel effect simultaneously in the atomic and the optical system. Our many-body formalism is perfectly suited to theoretically describe contemporary high-precision atom interferometric experiments based on entanglement between the atoms, that aim to surpass the shot-noise limit.