Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2303.03860 · Physical Review A

Electron-spin double resonance of nitrogen-vacancy centers in diamond under a strong driving field

Takumi Mikawa, Ryusei Okaniwa, Yuichiro Matsuzaki, Norio Tokuda, Junko Ishi‐Hayase

Published Jul 10, 2023• 9 citations
arXivHTMLPDF

Abstract

The nitrogen-vacancy (NV) center in diamond has been the focus of research efforts because of its suitability for use in applications such as quantum sensing and quantum simulations. Recently, the electron-spin double resonance (ESDR) of NV centers has been exploited for detecting radio-frequency (RF) fields with continuous-wave optically detected magnetic resonance. However, the characteristic phenomenon of ESDR under a strong RF field remains to be fully elucidated. In this study, we theoretically and experimentally analyzed the ESDR spectra under strong RF fields by adopting Floquet theory. Our analytical and numerical calculations could reproduce the ESDR spectra obtained by measuring the spin-dependent photoluminescence under the continuous application of a microwave and a RF field for a DC bias magnetic field perpendicular to the NV axis. We found that anticrossing structures that appear under a strong RF field are induced by the generation of RF-dressed states owing to the two-RF-photon resonances. Moreover, we found that $2n$-RF-photon resonances were allowed by an unintentional DC bias magnetic field parallel to the NV axis. These results should help in the realization of precise MHz-range AC magnetometry with a wide dynamic range beyond the rotating wave approximation regime as well as Floquet engineering in open quantum systems.

DOI
10.1103/physreva.108.012610

Related papers

Frequency-tunable magnetic field sensing using continuous-wave optically detected magnetic resonance with nitrogen-vacancy centers in diamond

Ryusei Okaniwa, Takumi Mikawa, Yuichiro Matsuzaki +8 more

The nitrogen-vacancy (NV) center is a promising candidate to realize practical quantum sensors with high sensitivity and high spatial resolution at room temperature and atmospheric pressure. In conventional high-frequency AC magnetometry with NV centers, the setup requires a pulse sequence with an appropriate time synchronization and strong microwave power. To avoid these practical difficulties, AC magnetometry using continuous-wave optically detected magnetic resonance (CW-ODMR) was recently demonstrated. That previous study utilized radio frequency (RF)-dressed states generated by the coherent interaction between the electron spin of the NV center and the RF wave. However, the drawback of this method is that the detectable frequency of the AC magnetic fields is fixed. Here, we propose and demonstrate frequency-tunable magnetic field sensing based on CW-ODMR. In the new sensing scheme, we obtain RF double-dressed states by irradiation with RF fields at two different frequencies. One creates the RF-dressed states and changes the frequency of the target AC field. The other is a target AC field that induces a change in the CW-ODMR spectrum by generating the RF double-dressed states through coherent interaction with the RF-dressed states. The sensitivity of our method is estimated to be comparable to or even higher than that of the conventional method based on the RF field with a single frequency. The estimated bandwidth is 7.5 MHz, higher than that of the conventional method using the RF-dressed states. Our frequency-tunable magnetic field sensor based on CW-ODMR paves the way for new applications in diamond devices.

arXiv:2305.12141•Journal of Applied Physics•Jan 22, 2024•8 citations

Nonlinear dynamics of a two-level system of a single spin driven beyond the rotating-wave approximation

K. R. K. Rao, Dieter Suter

Quantum systems driven by strong oscillating fields are the source of many interesting physical phenomena. In this work, we experimentally study the dynamics of a two-level system of a single spin driven in the strong-driving regime where the rotating-wave approximation is not valid. This two-level system is a subsystem of a single nitrogen-vacancy (NV) center in diamond coupled to a first-shell $^{13}\mathrm{C}$ nuclear spin at a level anticrossing point. This near degeneracy occurs in the ${m}_{s}=\ifmmode\pm\else\textpm\fi{}1$ manifold of the electron spin when the energy level splitting between the ${m}_{s}=\ensuremath{-}1$ and $+1$ states due to the static magnetic field is $\ensuremath{\approx}127$ MHz and thus equal to the splitting due to the $^{13}\mathrm{C}$ hyperfine interaction. The transition frequency of this electron spin two-level system in a static magnetic field of 28.9 G is 1.7 MHz and it can be driven only by the component of the radio-frequency (RF) field along the NV symmetry axis. Electron spin Rabi frequencies in this system can reach tens of MHz even for moderate RF powers. The simple sinusoidal Rabi oscillations that occur when the amplitude of the driving field is small compared to the transition frequency evolve into complex patterns when the driving field amplitude is comparable to or greater than the energy level splitting. We observe that the system oscillates faster than the amplitude of the driving field and the response of the system shows multiple frequencies.

arXiv:1610.04512•Physical Review A•May 1, 2017•20 citations

Broadband AC Magnetic Field Sensing via Continuous wave optically detected magnetic resonance with NV Centers in diamond

Ryohei Dokai, Ryusei Okaniwa, Miku Ishizaki +2 more

The nitrogen-vacancy (NV) center in diamond has attracted considerable attention as a highly sensitive quantum sensor that can operate at room temperature. In particular, continuous-wave optically detected magnetic resonance (CW-ODMR) is promising for a wide range of applications because of its simplicity. However, conventional AC magnetic-field sensing schemes based on CW-ODMR suffer from a limited detection bandwidth: the detectable frequency is either fixed by intrinsic physical parameters of the NV center or, even when tunable, restricted to a narrow range of only a few MHz. Here, we propose a broadband AC magnetometry scheme based on CW-ODMR with NV centers using microwave-driven dressed states.Through theoretical analysis and numerical simulations, we show that the proposed scheme enables the detection of AC magnetic fields with frequencies up to the order of 100 MHz, which has been difficult to achieve using conventional CW-ODMR-based methods.

quant-pharXiv:2606.05928•Japanese Journal of Applied Physics•Jun 5, 2026•1 citation

Radio-Frequency Excitation for Quantum Sensing Based on Diamond NV Center Using Coplanar Waveguide Transmission Lines

Aashutosh Kumar, Maxime Colson, Richard Al Hadi +1 more

The Nitrogen-Vacancy (NV) center in diamond is a prominent quantum system leveraged for advanced quantum metrology, particularly in high-precision magnetometry and high-resolution quantum imaging, exploiting the Optically Detected Magnetic Resonance (ODMR) spectroscopy technique. Proper radio-frequency (RF) excitation of NV centers is critical in order to manipulate these quantum states effectively. Our research focuses on optimizing the continuous-wave RF excitation of ensembles of NV centers on coplanar waveguide transmission lines (CPW-TL), measuring the centers' photoluminescence (PL) signal as a function of RF power. This setup enhances the sensitivity and resolution of the NV center PL signal. By combining CPW-TL lines with nanodiamonds, our approach aims to develop a scalable and tunable platform that can be deployed in a variety of quantum sensing scenarios, including in biomedical applications, navigation systems, environmental monitorlng, and beyond.

IEEE International Conference on Quantum Computing and Engineering (QCE)•Sep 15, 2024•2 citations

Room-temperature inversionless diamond nitrogen-vacancy electronic spin maser

Ali Fawaz, Sarath Raman Nair

We propose a method to create a room-temperature maser operating at approximately 2.9~GHz frequency using an ensemble of negatively charged nitrogen-vacancy electronic spins (NV) in diamond, without requiring population inversion. Our method considers a DC magnetic field of a few milli-Tesla (mT) applied along the perpendicular direction of an ensemble of NV spins aligned along a common axis. This perpendicular magnetic-field creates superposition states of $|m_{\mathrm{s}}=-1\rangle$ and $|m_{\mathrm{s}}=+1\rangle$ of the NV spin's ground state triplet levels and thereby makes it possible to drive all three transitions in the NV spin ground state. We model the system by including optical pumping of the NV spins, near-resonant driving of two transitions, and coupling the third transition to a near-resonant microwave resonator. Numerical estimates using experimentally realizable parameters show that inversionless masing can be achieved inside the microwave resonator using our method. As an application, we show that the output intensity of an inversionless maser ($1.1\times10^{14}$ spins) can be used for magnetic field sensing with a DC sensitivity on the order of a hundred pT/$\sqrt{\mathrm{Hz}}$. Our study opens a new direction in room-temperature diamond NV maser devices for quantum technological applications without the requirement of a strong bias magnetic field, as in conventional NV diamond masers.

quant-pharXiv:2607.07124•Jul 9, 2026•0 citations

Photoluminescence at the ground-state level anticrossing of the nitrogen-vacancy center in diamond: A comprehensive study

Viktor Ivády, Huijie Zheng, Arne Wickenbrock +9 more

The nitrogen-vacancy center (NV center) in diamond at magnetic fields corresponding to the ground-state level anticrossing (GSLAC) region gives rise to rich photoluminescence (PL) signals due to the vanishing energy gap between the electron spin states, which enables for a broad variety of environmental couplings to have an effect on the NV center's luminescence. Previous works have addressed several aspects of the GSLAC photoluminescence, however, a comprehensive analysis of the GSLAC signature of NV ensembles in different spin environments at various external fields is missing. Here we employ a combination of experiments and recently developed numerical methods to investigate in detail the effects of transverse electric and magnetic fields, strain, P1 centers, NV centers, and the $^{13}\mathrm{C}$ nuclear spins on the GSLAC photoluminescence. Our comprehensive analysis provides a solid ground for advancing various microwave-free applications at the GSLAC, including but not limited to magnetometry, spectroscopy, dynamic nuclear polarization (DNP), and nuclear magnetic resonance (NMR) detection. We demonstrate that not only the most abundant $^{14}\mathrm{NV}$ center but the $^{15}\mathrm{NV}$ can also be utilized in such applications.

arXiv:2006.05085•Physical review. B./Physical review. B•Jan 20, 2021•36 citations
The nitrogen-vacancy (NV) center in diamond has been the focus of research efforts because of its suitability for use in applications such as quantum sensing and quantum simulations. Recently, the electron-spin double resonance (ESDR) of NV centers has been exploited for detecting radio-frequency (RF) fields with continuous-wave optically detected magnetic resonance. However, the characteristic phenomenon of ESDR under a strong RF field remains to be fully elucidated. In this study, we theoretically and experimentally analyzed the ESDR spectra under strong RF fields by adopting Floquet theory. Our analytical and numerical calculations could reproduce the ESDR spectra obtained by measuring the spin-dependent photoluminescence under the continuous application of a microwave and a RF field for a DC bias magnetic field perpendicular to the NV axis. We found that anticrossing structures that appear under a strong RF field are induced by the generation of RF-dressed states owing to the two-RF-photon resonances. Moreover, we found that 2n2n2n-RF-photon resonances were allowed by an unintentional DC bias magnetic field parallel to the NV axis. These results should help in the realization of precise MHz-range AC magnetometry with a wide dynamic range beyond the rotating wave approximation regime as well as Floquet engineering in open quantum systems.
The nitrogen-vacancy (NV) center is a promising candidate to realize practical quantum sensors with high sensitivity and high spatial resolution at room temperature and atmospheric pressure. In conventional high-frequency AC magnetometry with NV centers, the setup requires a pulse sequence with an appropriate time synchronization and strong microwave power. To avoid these practical difficulties, AC magnetometry using continuous-wave optically detected magnetic resonance (CW-ODMR) was recently demonstrated. That previous study utilized radio frequency (RF)-dressed states generated by the coherent interaction between the electron spin of the NV center and the RF wave. However, the drawback of this method is that the detectable frequency of the AC magnetic fields is fixed. Here, we propose and demonstrate frequency-tunable magnetic field sensing based on CW-ODMR. In the new sensing scheme, we obtain RF double-dressed states by irradiation with RF fields at two different frequencies. One creates the RF-dressed states and changes the frequency of the target AC field. The other is a target AC field that induces a change in the CW-ODMR spectrum by generating the RF double-dressed states through coherent interaction with the RF-dressed states. The sensitivity of our method is estimated to be comparable to or even higher than that of the conventional method based on the RF field with a single frequency. The estimated bandwidth is 7.5 MHz, higher than that of the conventional method using the RF-dressed states. Our frequency-tunable magnetic field sensor based on CW-ODMR paves the way for new applications in diamond devices.
Quantum systems driven by strong oscillating fields are the source of many interesting physical phenomena. In this work, we experimentally study the dynamics of a two-level system of a single spin driven in the strong-driving regime where the rotating-wave approximation is not valid. This two-level system is a subsystem of a single nitrogen-vacancy (NV) center in diamond coupled to a first-shell 13C^{13}\mathrm{C}13C nuclear spin at a level anticrossing point. This near degeneracy occurs in the ${m}_{s}=\ifmmode\pm\else\textpm\fi{}1$ manifold of the electron spin when the energy level splitting between the ${m}_{s}=\ensuremath{-}1$ and +1+1+1 states due to the static magnetic field is $\ensuremath{\approx}127$ MHz and thus equal to the splitting due to the 13C^{13}\mathrm{C}13C hyperfine interaction. The transition frequency of this electron spin two-level system in a static magnetic field of 28.9 G is 1.7 MHz and it can be driven only by the component of the radio-frequency (RF) field along the NV symmetry axis. Electron spin Rabi frequencies in this system can reach tens of MHz even for moderate RF powers. The simple sinusoidal Rabi oscillations that occur when the amplitude of the driving field is small compared to the transition frequency evolve into complex patterns when the driving field amplitude is comparable to or greater than the energy level splitting. We observe that the system oscillates faster than the amplitude of the driving field and the response of the system shows multiple frequencies.
The nitrogen-vacancy (NV) center in diamond has attracted considerable attention as a highly sensitive quantum sensor that can operate at room temperature. In particular, continuous-wave optically detected magnetic resonance (CW-ODMR) is promising for a wide range of applications because of its simplicity. However, conventional AC magnetic-field sensing schemes based on CW-ODMR suffer from a limited detection bandwidth: the detectable frequency is either fixed by intrinsic physical parameters of the NV center or, even when tunable, restricted to a narrow range of only a few MHz. Here, we propose a broadband AC magnetometry scheme based on CW-ODMR with NV centers using microwave-driven dressed states.Through theoretical analysis and numerical simulations, we show that the proposed scheme enables the detection of AC magnetic fields with frequencies up to the order of 100 MHz, which has been difficult to achieve using conventional CW-ODMR-based methods.
The Nitrogen-Vacancy (NV) center in diamond is a prominent quantum system leveraged for advanced quantum metrology, particularly in high-precision magnetometry and high-resolution quantum imaging, exploiting the Optically Detected Magnetic Resonance (ODMR) spectroscopy technique. Proper radio-frequency (RF) excitation of NV centers is critical in order to manipulate these quantum states effectively. Our research focuses on optimizing the continuous-wave RF excitation of ensembles of NV centers on coplanar waveguide transmission lines (CPW-TL), measuring the centers' photoluminescence (PL) signal as a function of RF power. This setup enhances the sensitivity and resolution of the NV center PL signal. By combining CPW-TL lines with nanodiamonds, our approach aims to develop a scalable and tunable platform that can be deployed in a variety of quantum sensing scenarios, including in biomedical applications, navigation systems, environmental monitorlng, and beyond.
We propose a method to create a room-temperature maser operating at approximately 2.9~GHz frequency using an ensemble of negatively charged nitrogen-vacancy electronic spins (NV) in diamond, without requiring population inversion. Our method considers a DC magnetic field of a few milli-Tesla (mT) applied along the perpendicular direction of an ensemble of NV spins aligned along a common axis. This perpendicular magnetic-field creates superposition states of ∣ms=−1⟩|m_{\mathrm{s}}=-1\rangle∣ms​=−1⟩ and ∣ms=+1⟩|m_{\mathrm{s}}=+1\rangle∣ms​=+1⟩ of the NV spin's ground state triplet levels and thereby makes it possible to drive all three transitions in the NV spin ground state. We model the system by including optical pumping of the NV spins, near-resonant driving of two transitions, and coupling the third transition to a near-resonant microwave resonator. Numerical estimates using experimentally realizable parameters show that inversionless masing can be achieved inside the microwave resonator using our method. As an application, we show that the output intensity of an inversionless maser (1.1×10141.1\times10^{14}1.1×1014 spins) can be used for magnetic field sensing with a DC sensitivity on the order of a hundred pT/Hz\sqrt{\mathrm{Hz}}Hz​. Our study opens a new direction in room-temperature diamond NV maser devices for quantum technological applications without the requirement of a strong bias magnetic field, as in conventional NV diamond masers.
The nitrogen-vacancy center (NV center) in diamond at magnetic fields corresponding to the ground-state level anticrossing (GSLAC) region gives rise to rich photoluminescence (PL) signals due to the vanishing energy gap between the electron spin states, which enables for a broad variety of environmental couplings to have an effect on the NV center's luminescence. Previous works have addressed several aspects of the GSLAC photoluminescence, however, a comprehensive analysis of the GSLAC signature of NV ensembles in different spin environments at various external fields is missing. Here we employ a combination of experiments and recently developed numerical methods to investigate in detail the effects of transverse electric and magnetic fields, strain, P1 centers, NV centers, and the 13C^{13}\mathrm{C}13C nuclear spins on the GSLAC photoluminescence. Our comprehensive analysis provides a solid ground for advancing various microwave-free applications at the GSLAC, including but not limited to magnetometry, spectroscopy, dynamic nuclear polarization (DNP), and nuclear magnetic resonance (NMR) detection. We demonstrate that not only the most abundant 14NV^{14}\mathrm{NV}14NV center but the 15NV^{15}\mathrm{NV}15NV can also be utilized in such applications.