Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2301.00110 · Physical Review Applied

Fast high-fidelity charge readout by operating a cavity-embedded Cooper-pair transistor in the Kerr bistable regime

B. Thyagarajan, S. Kanhirathingal, Benjamin L. Brock, Juliang Li, M. P. Blencowe, A. J. Rimberg

Published Jan 31, 2024• 3 citations
arXivHTMLPDF

Abstract

Operating the cavity-embedded Cooper-pair transistor (CCPT) in the Kerr bistable regime, we demonstrate single-shot resolution between two charge states that are $0.09e$ apart. The measurement is performed with $94\mathrm{%}$ fidelity in a duration of around $3\phantom{\rule{0.2em}{0ex}}\text{\ensuremath{\mu}}\mathrm{s}$. This is done with a drive power that corresponds to only 20 intracavity photons on average in the high oscillation amplitude state of the CCPT, which is orders of magnitude smaller than that in rf single electron transistors. We find that the limiting factor for this mode of operation of the CCPT is the spontaneous fluctuation-induced switching between the two metastable oscillation amplitude states. We present empirical data on the variation of the switching dynamics with drive parameters and CCPT dc bias.

DOI
10.1103/physrevapplied.21.014064

Related papers

Charge sensitivity of a cavity-embedded Cooper pair transistor limited by single-photon shot noise

S. Kanhirathingal, B. L. Brock, A. J. Rimberg +1 more

Using an operator scattering approach, we analyze the quantum dynamics of an ultrasensitive electrometer—a Cooper pair transistor embedded in a quarter-wave microwave cavity (cCPT). While the cCPT is inherently a tunable, strongly nonlinear system affording a diverse range of functionalities, we restrict our present analysis to a necessary first investigation of its linear charge sensing capabilities, limiting to low pump powers corresponding to an average cavity photon number of ≲1. Assuming realizable cCPT parameters [B. L. Brock et al., Phys. Rev. Applied 15, 044009 (2021)], and not including noise from the subsequent amplifier chain, we predict the fundamental, photon shot noise-limited charge sensitivity to be 0.12μe/Hz when the pumped cavity has an average of one photon and the cCPT is operated close to charge degeneracy. This is to be compared with a first reported charge sensitivity value of 14μe/Hz in the single-photon regime [B. L. Brock et al., arXiv:2102.05362 (2021)].

arXiv:2012.12313•Journal of Applied Physics•Sep 17, 2021•4 citations

Fast and Ultrasensitive Electrometer Operating at the Single-Photon Level

Benjamin L. Brock, Juliang Li, S. Kanhirathingal +3 more

Fast, ultrasensitive electrometers have been instrumental to the advancement of basic science. However, many applications (such as readout of quantum-dot-based qubits, and mediation of optomechanical interactions) could benefit from operating such charge sensors at low power. Here the authors demonstrate a charge sensitivity of 14 $\ensuremath{\mu}\phantom{\rule{0}{0ex}}e/\sqrt{\mathrm{Hz}}$ with a cavity-embedded Cooper-pair transistor (CCPT) using 16 aW of power, which corresponds to the single-photon level of the cavity. These results support the feasibility of using a CCPT to mediate an optomechanical interaction that reaches the single-photon strong-coupling regime.

arXiv:2102.05362•Physical Review Applied•Nov 22, 2021•7 citations

Nonlinear Charge- and Flux-Tunable Cavity Derived From an Embedded Cooper-Pair Transistor

B.L. Brock, Juliang Li, S. Kanhirathingal +4 more

We introduce the cavity-embedded Cooper-pair transistor (cCPT), a device that behaves as a highly nonlinear microwave cavity whose resonant frequency can be tuned both by charging a gate capacitor and by threading flux through a superconducting loop. We characterize this device and find excellent agreement between theory and experiment. A key difficulty in this characterization is the presence of frequency fluctuations comparable in scale to the cavity linewidth, which deform our measured resonance circles in accordance with recent theoretical predictions [Brock et al., Phys. Rev. Appl. 14, 054026 (2020)]. By measuring the power spectral density of these frequency fluctuations at carefully chosen points in parameter space, we find that they are primarily a result of the $1/f$ charge and flux noise common in solid-state devices. Notably, we also observe key signatures of frequency fluctuations induced by quantum fluctuations in the cavity field via the Kerr nonlinearity.

arXiv:2011.06298•Physical Review Applied•Apr 5, 2021•11 citations

Towards Single Shot Measurements of a Cooper Pair Box Qubit Using an RF Single Electron Transistor

Carlos Alberto Sánchez

I report an investigation into using an rf Single Electron Transistor (rf-SET) to implement single shot readout of the quantum state of a Cooper pair box. I fabricated Al/AlOx/Al SETs and Cooper pair boxes using e-beam lithography and double-angle evaporation. The devices had typical charging energies of about 1 K and were measured at 30 mK in a dilution refrigerator. I built rf-SETs with an LC resonant circuit integrated on the chip and operating frequencies of 650 MHz and 1.5 GHz. The rf-SETs had a typical bandwidth of 30 MHz and the best achieved charge sensitivity was 8X10-6 erms/(Hz)1/2 at 1.5 GHz. The rf-SETs were used to measure the Coulomb staircase on the Cooper pair box. Measurements of the staircase show features due to quasiparticle poisoning that are dependent on temperature and SET bias. The data was compared to a theory I developed to extend existing theories of quasiparticle poisoning. My model is based on the calculation of tunneling rates to explain observations of parity effects in the Cooper pair box over a wide temperature range. Quantum state control of the Cooper pair box was demonstrated by using fast voltage pulses applied to the gate. Temporal oscillations of charge states and spectroscopy measurements reveal a dephasing time T2=200 ps at 30 mK, for a drive frequency of 30 GHz. The energy relaxation time T1=140 ns was determined from time domain measurements of the decay of the Cooper pair box charge. The fidelity of single shot measurements and the feasibility of this quantum readout scheme based on the results are discussed.

•Dec 5, 2005•0 citations

Feedback Stabilization of the Resonant Frequency in a Tunable Microwave Cavity with Single-Photon Occupancy

S. Kanhirathingal, B. Thyagarajan, Benjamin L. Brock +5 more

We successfully demonstrate low-frequency noise suppression in the resonant-frequency fluctuations of a cavity-embedded Cooper-pair transistor (cCPT) driven at single-photon occupancy. In particular, we report a reduction in the resonant-frequency fluctuations caused by the internal charge noise over a bandwidth of approximately $1.4\phantom{\rule{0.2em}{0ex}}\text{kHz}$ when the cavity is driven at an average photon number $n=10$ and a bandwidth of 11 Hz for an average $n=1$. The gate-dependent tunability of the cCPT allows us to implement a feedback scheme derived from the Pound-Drever-Hall locking technique. This reduces fluctuations due to intrinsic charge noise, which otherwise interfere with the operation of the cCPT as a near quantum-limited electrometer. Our technique can be generalized to achieve frequency stabilization in tunable microwave resonators that play a vital role in today's quantum computing architectures, thereby moderating the limitations in detection caused by the intrinsic $1/f$ noise on such circuit devices. The work discusses the various aspects relating to the operation of a fully functional feedback loop down to the single-photon level.

arXiv:2202.04227•Physical Review Applied•Dec 13, 2022•3 citations

Observation of Quantum Capacitance in the Cooper-Pair Transistor

T. Duty, Göran Johansson, Kevin Bladh +3 more

We have fabricated a Cooper-pair transistor (CPT) with parameters such that for appropriate voltage biases, it behaves essentially like a single Cooper-pair box (SCB). The effective capacitance of a SCB can be defined as the derivative of the induced charge with respect to gate voltage and has two parts, the geometric capacitance, C(geom), and the quantum capacitance C(Q). The latter is due to the level anticrossing caused by the Josephson coupling and is dual to the Josephson inductance. It depends parametrically on the gate voltage and its magnitude may be substantially larger than C(geom). We have detected C(Q) in our CPT, by measuring the in phase and quadrature rf signal reflected from a resonant circuit in which the CPT is embedded. C(Q) can be used as the basis of a charge qubit readout by placing a Cooper-pair box in such a resonant circuit.

arXiv:cond-mat/0503531•Physical Review Letters•Nov 11, 2005•134 citations
Operating the cavity-embedded Cooper-pair transistor (CCPT) in the Kerr bistable regime, we demonstrate single-shot resolution between two charge states that are 0.09e0.09e0.09e apart. The measurement is performed with 94\mathrm{%} fidelity in a duration of around 3\ensuremath\mus3\phantom{\rule{0.2em}{0ex}}\text{\ensuremath{\mu}}\mathrm{s}3\ensuremath\mus. This is done with a drive power that corresponds to only 20 intracavity photons on average in the high oscillation amplitude state of the CCPT, which is orders of magnitude smaller than that in rf single electron transistors. We find that the limiting factor for this mode of operation of the CCPT is the spontaneous fluctuation-induced switching between the two metastable oscillation amplitude states. We present empirical data on the variation of the switching dynamics with drive parameters and CCPT dc bias.
Using an operator scattering approach, we analyze the quantum dynamics of an ultrasensitive electrometer—a Cooper pair transistor embedded in a quarter-wave microwave cavity (cCPT). While the cCPT is inherently a tunable, strongly nonlinear system affording a diverse range of functionalities, we restrict our present analysis to a necessary first investigation of its linear charge sensing capabilities, limiting to low pump powers corresponding to an average cavity photon number of ≲1. Assuming realizable cCPT parameters [B. L. Brock et al., Phys. Rev. Applied 15, 044009 (2021)], and not including noise from the subsequent amplifier chain, we predict the fundamental, photon shot noise-limited charge sensitivity to be 0.12μe/Hz when the pumped cavity has an average of one photon and the cCPT is operated close to charge degeneracy. This is to be compared with a first reported charge sensitivity value of 14μe/Hz in the single-photon regime [B. L. Brock et al., arXiv:2102.05362 (2021)].
Fast, ultrasensitive electrometers have been instrumental to the advancement of basic science. However, many applications (such as readout of quantum-dot-based qubits, and mediation of optomechanical interactions) could benefit from operating such charge sensors at low power. Here the authors demonstrate a charge sensitivity of 14 $\ensuremath{\mu}\phantom{\rule{0}{0ex}}e/\sqrt{\mathrm{Hz}}$ with a cavity-embedded Cooper-pair transistor (CCPT) using 16 aW of power, which corresponds to the single-photon level of the cavity. These results support the feasibility of using a CCPT to mediate an optomechanical interaction that reaches the single-photon strong-coupling regime.
We introduce the cavity-embedded Cooper-pair transistor (cCPT), a device that behaves as a highly nonlinear microwave cavity whose resonant frequency can be tuned both by charging a gate capacitor and by threading flux through a superconducting loop. We characterize this device and find excellent agreement between theory and experiment. A key difficulty in this characterization is the presence of frequency fluctuations comparable in scale to the cavity linewidth, which deform our measured resonance circles in accordance with recent theoretical predictions [Brock et al., Phys. Rev. Appl. 14, 054026 (2020)]. By measuring the power spectral density of these frequency fluctuations at carefully chosen points in parameter space, we find that they are primarily a result of the 1/f1/f1/f charge and flux noise common in solid-state devices. Notably, we also observe key signatures of frequency fluctuations induced by quantum fluctuations in the cavity field via the Kerr nonlinearity.
I report an investigation into using an rf Single Electron Transistor (rf-SET) to implement single shot readout of the quantum state of a Cooper pair box. I fabricated Al/AlOx/Al SETs and Cooper pair boxes using e-beam lithography and double-angle evaporation. The devices had typical charging energies of about 1 K and were measured at 30 mK in a dilution refrigerator. I built rf-SETs with an LC resonant circuit integrated on the chip and operating frequencies of 650 MHz and 1.5 GHz. The rf-SETs had a typical bandwidth of 30 MHz and the best achieved charge sensitivity was 8X10-6 erms/(Hz)1/2 at 1.5 GHz. The rf-SETs were used to measure the Coulomb staircase on the Cooper pair box. Measurements of the staircase show features due to quasiparticle poisoning that are dependent on temperature and SET bias. The data was compared to a theory I developed to extend existing theories of quasiparticle poisoning. My model is based on the calculation of tunneling rates to explain observations of parity effects in the Cooper pair box over a wide temperature range. Quantum state control of the Cooper pair box was demonstrated by using fast voltage pulses applied to the gate. Temporal oscillations of charge states and spectroscopy measurements reveal a dephasing time T2=200 ps at 30 mK, for a drive frequency of 30 GHz. The energy relaxation time T1=140 ns was determined from time domain measurements of the decay of the Cooper pair box charge. The fidelity of single shot measurements and the feasibility of this quantum readout scheme based on the results are discussed.
We successfully demonstrate low-frequency noise suppression in the resonant-frequency fluctuations of a cavity-embedded Cooper-pair transistor (cCPT) driven at single-photon occupancy. In particular, we report a reduction in the resonant-frequency fluctuations caused by the internal charge noise over a bandwidth of approximately 1.4kHz1.4\phantom{\rule{0.2em}{0ex}}\text{kHz}1.4kHz when the cavity is driven at an average photon number n=10n=10n=10 and a bandwidth of 11 Hz for an average n=1n=1n=1. The gate-dependent tunability of the cCPT allows us to implement a feedback scheme derived from the Pound-Drever-Hall locking technique. This reduces fluctuations due to intrinsic charge noise, which otherwise interfere with the operation of the cCPT as a near quantum-limited electrometer. Our technique can be generalized to achieve frequency stabilization in tunable microwave resonators that play a vital role in today's quantum computing architectures, thereby moderating the limitations in detection caused by the intrinsic 1/f1/f1/f noise on such circuit devices. The work discusses the various aspects relating to the operation of a fully functional feedback loop down to the single-photon level.
We have fabricated a Cooper-pair transistor (CPT) with parameters such that for appropriate voltage biases, it behaves essentially like a single Cooper-pair box (SCB). The effective capacitance of a SCB can be defined as the derivative of the induced charge with respect to gate voltage and has two parts, the geometric capacitance, C(geom), and the quantum capacitance C(Q). The latter is due to the level anticrossing caused by the Josephson coupling and is dual to the Josephson inductance. It depends parametrically on the gate voltage and its magnitude may be substantially larger than C(geom). We have detected C(Q) in our CPT, by measuring the in phase and quadrature rf signal reflected from a resonant circuit in which the CPT is embedded. C(Q) can be used as the basis of a charge qubit readout by placing a Cooper-pair box in such a resonant circuit.