Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2209.11917

Super-resolution atomic microscopy using orbit angular momentum laser with temporal modulation

Liu, Yuan, Dongxiao Li

Published Sep 24, 2022• 0 citations
arXivHTMLPDF

Abstract

In this paper we propose a dark-state-based trapping strategy to break the optical diffraction limit for microscopy. We utilize a spatially dependent coupling field and a probe laser field with temporal and spatial modulation to interact with three-level atoms. The temporal modulation allows us to reduce the full width at half maximum (FWHM) of point spread function, and the spatial modulation help us obtain better spatial resolution than Gaussian beam. In addition, we also propose a proof-of-principle experiment protocol and discuss its feasibility.

DOI
10.48550/arxiv.2209.11917

Related papers

Subnanoscale resolution for microscopy via coherent population trapping

Kishore T. Kapale, G. S. Agarwal

We present a coherent-population-trapping-based scheme to attain subnanoscale resolution for microscopy. We use three-level atoms coupled to an amplitude modulated probe field and a spatially dependent (standing-wave or Laguerre-Gaussian) coupling field. The probe field modulation allows us to tap into the steep dispersion normally associated with electromagnetically induced transparency and offers subnanometer resolution using optical fields.

arXiv:0912.1289•Optics Letters•Aug 13, 2010•39 citations

Sub-nanoscale Resolution for Microscopy via Coherent Population Trapping

Kishore T. Kapale, G. S. Agarwal

We present a coherent population trapping based scheme to attain sub-nanoscale resolution for microscopy using three-level atoms coupled to two optical fields---amplitude modulated probe field and a spatially dependent coupling field.

Bulletin of the American Physical Society•Jun 16, 2011•0 citations

Sub-nanoscale Resolution for Microscopy via Coherent Population Trapping

Kishore T. Kapale, G. S. Agarwal

We present a coherent population trapping based scheme to attain sub-nanoscale resolution for microscopy using three-level atoms coupled to two optical fields—amplitude modulated probe field and a spatially dependent coupling field.

Frontiers in Optics•Jan 1, 2010•2 citations

Identification of orbital angular momentum using atom-based spatial self-phase modulation

Wei Gao, Sandan Wang, Jinpeng Yuan +3 more

Optical vortex orbital angular momentum modes, namely the twists number of the light does in one wavelength, play a critical role in quantum-information coding, super-resolution imaging, and high-precision optical measurement. Here, we present the identification of the orbital angular momentum modes based on spatial self-phase modulation in rubidium atomic vapor. The refractive index of atomic medium is spatially modulated by the focused vortex laser beam, and the resulted nonlinear phase shift of beam directly related to the orbital angular momentum modes. The output diffraction pattern carries clearly distinguishable tails, whose number and rotation direction correspond to the magnitude and sign of the input beam orbital angular momentum, respectively. Furthermore, the visualization degree of orbital angular momentums identification is adjusted on-demand in the terms of incident power and frequency detuning. These results show that the spatial self-phase modulation of atomic vapor can provide a feasible and effective way to rapidly readout the orbital angular momentum modes of vortex beam.

Optics Express•Mar 24, 2023•9 citations

Optical Lithography and Atom Localization beyond the Diffraction Limit via Rabi Gradient

Zeyang Liao

The resolution of traditional optical microscope and optical lithography is limited by about half wavelength of the light source, which is well known as the diffraction limit or Abbe limit. The resolution limit is due to the missing of high spatial frequency components in the far-field. One way to achieve high resolution is to move the detector into the near-field region where the evanescent wave can be collected. However, these methods are surface-bound and usually very slow which have limited applications. It has long been an interesting and important question about how to overcome the diffraction limit in the far-field.\n\nFor optical lithography, a number of methods have been proposed to overcome the diffraction limit such as multi-photon scanning, quantum entanglement, quantum inspired process (e.g., dopperlon), and quantum dark state. However, these methods either require multi-photon absorber, quantum entanglement, or multi-energy levels, which restrict them from extending to higher resolution in practice. In this thesis, we showed that sub-diffraction-limited resolution can be generated by the coherent Rabi gradient. This method does not require multi-photon absorber or quantum entanglement but just quantum coherence of the medium. Extension from lower resolution to higher resolution is very straightforward where we just need to increase the pulse intensity or pulse duration. We also proposed two atom lithography experiments based on the Rabi gradient. The first one uses Rubidium Rydberg atom and microwave where we showed that sub-micrometer line spacing is possible. The second one uses Chromium atom and optical field where we showed that sub-10nm line spacing is possible while the wavelength of the light is about 400nm.\n\nFor optical imaging, a number of methods have also been proposed to achieve super-resolution such as multi-photon microscope, stimulated-emission-depletion, structured illumination microscopy, centroid-based techniques and metamaterial-based lens. Here, we will show a new method to achieve resolution beyond the diffraction limit which we called it resonance fluorescence microscopy. Resonance fluorescence has been proposed to localize a single atom with resolution beyond the diffraction limit. The separation between two atoms can also be extracted from the resonance\nfluorescence spectrum. To develop it as microscopy, we need to evaluate the resonance fluorescence spectrum of multiple-atom system. We analytically solved the general feature of the spectrum when the Rabi frequency is much larger than the dipole-dipole interaction and showed how to extract the spatial information of the atoms with resolution far beyond the diffraction limit. This method is entirely based on far-field techniques and it does not require point-by-point scanning.

•Jul 28, 2014•0 citations

Structured detection microscopy

Larnii Booth, Kyle Clunies-Ross, Rumelo Amor +4 more

Super-resolution microscopy is crucial for imaging sub-wavelength biological structures. However, most techniques rely on nonlinear saturation or stochastic switching of emitters, limiting imaging speed and increasing phototoxicity. Here, we achieve deep super-resolution without employing saturation or stochastic dynamics, instead using a form of spatial mode demultiplexing. By shaping the point-spread function of the emitted light, our Structured Detection Microscope (SDM) redistributes information away from high shot-noise regions of the image, enhancing sensitivity to sub-diffraction emitter separations in two-dimensions and without mode-sorting optics. Implementing SDM within a high-numerical aperture total internal reflection fluorescence microscope, we demonstrate imaging of fluorophores attached to DNA nanorulers with separations as small as 50 nm at resolutions surpassing 40 nm - fivefold below the diffraction limit. This shows that spatial mode demultiplexing can achieve far sub-wavelength resolution and is applicable to biologically relevant samples. By enabling super-resolution biomolecular imaging without emitter saturation and stochasticity, our work opens the door to better understanding biological structure, function and dynamics.

physics.opticsCross-listedarXiv:2604.00413•Apr 2, 2026
In this paper we propose a dark-state-based trapping strategy to break the optical diffraction limit for microscopy. We utilize a spatially dependent coupling field and a probe laser field with temporal and spatial modulation to interact with three-level atoms. The temporal modulation allows us to reduce the full width at half maximum (FWHM) of point spread function, and the spatial modulation help us obtain better spatial resolution than Gaussian beam. In addition, we also propose a proof-of-principle experiment protocol and discuss its feasibility.
Optical vortex orbital angular momentum modes, namely the twists number of the light does in one wavelength, play a critical role in quantum-information coding, super-resolution imaging, and high-precision optical measurement. Here, we present the identification of the orbital angular momentum modes based on spatial self-phase modulation in rubidium atomic vapor. The refractive index of atomic medium is spatially modulated by the focused vortex laser beam, and the resulted nonlinear phase shift of beam directly related to the orbital angular momentum modes. The output diffraction pattern carries clearly distinguishable tails, whose number and rotation direction correspond to the magnitude and sign of the input beam orbital angular momentum, respectively. Furthermore, the visualization degree of orbital angular momentums identification is adjusted on-demand in the terms of incident power and frequency detuning. These results show that the spatial self-phase modulation of atomic vapor can provide a feasible and effective way to rapidly readout the orbital angular momentum modes of vortex beam.
The resolution of traditional optical microscope and optical lithography is limited by about half wavelength of the light source, which is well known as the diffraction limit or Abbe limit. The resolution limit is due to the missing of high spatial frequency components in the far-field. One way to achieve high resolution is to move the detector into the near-field region where the evanescent wave can be collected. However, these methods are surface-bound and usually very slow which have limited applications. It has long been an interesting and important question about how to overcome the diffraction limit in the far-field.\n\nFor optical lithography, a number of methods have been proposed to overcome the diffraction limit such as multi-photon scanning, quantum entanglement, quantum inspired process (e.g., dopperlon), and quantum dark state. However, these methods either require multi-photon absorber, quantum entanglement, or multi-energy levels, which restrict them from extending to higher resolution in practice. In this thesis, we showed that sub-diffraction-limited resolution can be generated by the coherent Rabi gradient. This method does not require multi-photon absorber or quantum entanglement but just quantum coherence of the medium. Extension from lower resolution to higher resolution is very straightforward where we just need to increase the pulse intensity or pulse duration. We also proposed two atom lithography experiments based on the Rabi gradient. The first one uses Rubidium Rydberg atom and microwave where we showed that sub-micrometer line spacing is possible. The second one uses Chromium atom and optical field where we showed that sub-10nm line spacing is possible while the wavelength of the light is about 400nm.\n\nFor optical imaging, a number of methods have also been proposed to achieve super-resolution such as multi-photon microscope, stimulated-emission-depletion, structured illumination microscopy, centroid-based techniques and metamaterial-based lens. Here, we will show a new method to achieve resolution beyond the diffraction limit which we called it resonance fluorescence microscopy. Resonance fluorescence has been proposed to localize a single atom with resolution beyond the diffraction limit. The separation between two atoms can also be extracted from the resonance\nfluorescence spectrum. To develop it as microscopy, we need to evaluate the resonance fluorescence spectrum of multiple-atom system. We analytically solved the general feature of the spectrum when the Rabi frequency is much larger than the dipole-dipole interaction and showed how to extract the spatial information of the atoms with resolution far beyond the diffraction limit. This method is entirely based on far-field techniques and it does not require point-by-point scanning.
Super-resolution microscopy is crucial for imaging sub-wavelength biological structures. However, most techniques rely on nonlinear saturation or stochastic switching of emitters, limiting imaging speed and increasing phototoxicity. Here, we achieve deep super-resolution without employing saturation or stochastic dynamics, instead using a form of spatial mode demultiplexing. By shaping the point-spread function of the emitted light, our Structured Detection Microscope (SDM) redistributes information away from high shot-noise regions of the image, enhancing sensitivity to sub-diffraction emitter separations in two-dimensions and without mode-sorting optics. Implementing SDM within a high-numerical aperture total internal reflection fluorescence microscope, we demonstrate imaging of fluorophores attached to DNA nanorulers with separations as small as 50 nm at resolutions surpassing 40 nm - fivefold below the diffraction limit. This shows that spatial mode demultiplexing can achieve far sub-wavelength resolution and is applicable to biologically relevant samples. By enabling super-resolution biomolecular imaging without emitter saturation and stochasticity, our work opens the door to better understanding biological structure, function and dynamics.