Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2206.11387 · Physical Review A

Quantum metrology timing limits of the Hong-Ou-Mandel interferometer and of general two-photon measurements

Kyle M. Jordan, Raphael A. Abrahão, Jeff S. Lundeen

Published Dec 22, 2022• 25 citations
arXivHTMLPDF

Abstract

We examine the precision limits of Hong-Ou-Mandel (HOM) timing measurements, as well as precision limits applying to generalized two-photon measurements. As a special case we consider the use of two-photon measurements using photons with variable bandwidths and frequency correlations. When the photon bandwidths are not equal, maximizing the measurement precision involves a tradeoff between high interference visibility and strong frequency anticorrelations, with the optimal precision occurring when the photons share nonmaximal frequency anticorrelations. We show that a generalized measurement has precision limits that are qualitatively similar to those of the HOM measurement whenever the generalized measurement is insensitive to the net delay of both photons. By examining the performance of states with more general frequency distributions, our analysis allows for engineering of the joint spectral amplitude for use in realistic situations, in which both photons may not have ideal spectral properties.

DOI
10.1103/physreva.106.063715

Related papers

Quantum Limits in Precision Hong-Ou-Mandel Interferometry

Kyle M. Jordan, Raphael A. Abrahão, Jeff S. Lundeen

We examine the precision limits of Hong-Ou-Mandel interferometry-based timing measurements using the Cramér-Rao bounds. We show how to adapt the method for realistic sources of photon pairs involving unequal mode bandwidths and nonmaximal frequency correlations.

Quantum 2.0 Conference and Exhibition•Jan 1, 2022•0 citations

Time-Frequency Quantum Metrology

Nicolas Fabre

Hong-Ou-Mandel interferometry takes advantage of the quantum nature of two-photon interference to increase the resolution of precision measurements of time delays. Relying on few-photon probe states, this approach is applicable also in cases of extremely sensible samples and it achieves attosecond-scale resolution, which is relevant to cell biology and two-dimensional materials. Here, we theoretically analyze how the precision of Hong-Ou-Mandel interferometers can be significantly improved by engineering the spectral distribution of two-photon probe states. In particular, we assess the metrological power of different classes of biphoton states with non-Gaussian time-frequency spectral distributions, considering the estimation of both time and frequency shifts. We find that grid states, characterized by a periodic structure of peaks in the chronocyclic Wigner function, can outperform standard biphoton states in sensing applications [1].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•0 citations

Quantum frequency combs and Hong–Ou–Mandel interferometry: the role of spectral phase coherence

Navin B. Lingaraju, Hsuan‐Hao Lu, Suparna Seshadri +4 more

The Hong-Ou-Mandel interferometer is a versatile tool for analyzing the joint properties of photon pairs, relying on a truly quantum interference effect between two-photon probability amplitudes. While the theory behind this form of two-photon interferometry is well established, the development of advanced photon sources and exotic two-photon states has highlighted the importance of quantifying precisely what information can and cannot be inferred from features in a Hong-Ou-Mandel interference trace. Here we examine Hong-Ou-Mandel interference with regard to a particular class of states, so-called quantum frequency combs, and place special emphasis on the role spectral phase plays in these measurements. We find that this form of two-photon interferometry is insensitive to the relative phase between different comb line pairs. This is true even when different comb line pairs are mutually coherent at the input of a Hong-Ou-Mandel interferometer and the fringe patterns display sharp temporal features. Consequently, Hong-Ou-Mandel interference cannot speak to the presence of high-dimensional frequency-bin entanglement in two-photon quantum frequency combs.

arXiv:1909.13823•Optics Express•Dec 9, 2019•35 citations

Parameter estimation of time and frequency shifts with generalized Hong, Ou and Mandel interferometry

Nicolas Fabre

Hong-Ou-Mandel interferometry takes advantage of the quantum nature of two-photon interference to increase the resolution of precision measurements of time-delays. Relying on few-photon probe states, this approach is applicable also in cases of extremely sensible samples and it achieves attosecond (nanometer path length) scale resolution, which is relevant to cell biology and two-dimensional materials. Here, we theoretically analyze how the precision of Hong-Ou-Mandel interferometers can be significantly improved by engineering the spectral distribution of two-photon probe states. In particular, we assess the metrological power of different classes of biphoton states with non-Gaussian time-frequency spectral distributions, considering the estimation of both time-and frequency-shifts. We find that grid states, characterized by a periodic structure of peaks in the chronocyclic Wigner function, can outperform standard biphoton states in sensing applications. The considered states can be feasibly produced with atomic photon sources, bulk non-linear crystals and integrated photonic waveguide devices.

SPIE Quantum Technologies•Jun 3, 2022•0 citations

Quantum metrology timing limits of biphoton frequency comb

Baihong Li, Qi-qi Li, Xiao-Fei Zhang +1 more

Biphoton frequency comb (BFC), which encompasses multiple discrete frequency modes and represents high-dimensional frequency entanglement, is crucial in quantum information processing due to its high information capacity and error resilience. It also holds significant potential for enhancing timing precision in quantum metrology. Here, we examine quantum metrology timing limits using the BFC as a probe state and derive a quantum Cramér-Rao bound (QCRB) that depends on the mode number, mode spacing, frequency detuning, and single-mode bandwidth. Our results coincide with previous findings that considered only the latter two factors. Under ideal conditions (zero loss and perfect visibility), this bound can be saturated by both spectrally non-resolved Hong-Ou-Mandel (HOM) interferometry at zero delay and spectrally resolved HOM interferometry at arbitrary delays. In practical scenarios, the Fisher information is below the QCRB but can approach its maximum by increasing the mode number and mode spacing for a fixed delay point, suggesting an optimal strategy for improving the precision of HOM-based sensing in practice. Furthermore, compared to spectrally non-resolved measurement, spectrally resolved measurement is a superior strategy due to its higher Fisher information, shorter measurement times, and ambiguity-free dynamic range.

arXiv:2410.16841•Optics Express•Jun 25, 2025•2 citations

Attosecond delay metrology beyond the photon coherence time with spectrally resolved Hong-Ou-Mandel interferometry

Yingwen Zhang, Kyle Jordan, Duncan England +3 more

Hong-Ou-Mandel (HOM) interferometry enables delay estimation at the quantum precision limit but is traditionally constrained to path differences within the coherence time of the interfering photons. Here, we demonstrate single-measurement path-delay sensing at the measurement Cramer-Rao bound using spectrally resolved HOM interference, thereby removing the conventional dynamic-range limitation imposed by the photon coherence window, with no scanning required for calibration. By extracting delay information from the spectral interference fringes of spectrally entangled photon pairs, we retain near-optimal sensitivity over an operational range exceeding the photon coherence time by over two orders of magnitude. Using one million detected photon pairs, we achieve a time-delay precision of 20 attosecond (6 nm), while real-time operation (at 1 Hz) yields 330 attosecond (100 nm) precision. Because the estimator relies on fringe periodicity rather than absolute coincidence rates, the method is intrinsically robust to photon losses and variations in interference visibility, eliminating the need for recalibration. As a practical demonstration, we measure the thickness of a 300 um transmissive target with nanometer-scale precision. These results mark a significant step towards deploying quantum-limited measurements in real-world sensing applications using HOM interferometry.

quant-pharXiv:2607.16849•Reports on Progress in Physics•Jul 21, 2026•0 citations
We examine the precision limits of Hong-Ou-Mandel (HOM) timing measurements, as well as precision limits applying to generalized two-photon measurements. As a special case we consider the use of two-photon measurements using photons with variable bandwidths and frequency correlations. When the photon bandwidths are not equal, maximizing the measurement precision involves a tradeoff between high interference visibility and strong frequency anticorrelations, with the optimal precision occurring when the photons share nonmaximal frequency anticorrelations. We show that a generalized measurement has precision limits that are qualitatively similar to those of the HOM measurement whenever the generalized measurement is insensitive to the net delay of both photons. By examining the performance of states with more general frequency distributions, our analysis allows for engineering of the joint spectral amplitude for use in realistic situations, in which both photons may not have ideal spectral properties.
Hong-Ou-Mandel interferometry takes advantage of the quantum nature of two-photon interference to increase the resolution of precision measurements of time delays. Relying on few-photon probe states, this approach is applicable also in cases of extremely sensible samples and it achieves attosecond-scale resolution, which is relevant to cell biology and two-dimensional materials. Here, we theoretically analyze how the precision of Hong-Ou-Mandel interferometers can be significantly improved by engineering the spectral distribution of two-photon probe states. In particular, we assess the metrological power of different classes of biphoton states with non-Gaussian time-frequency spectral distributions, considering the estimation of both time and frequency shifts. We find that grid states, characterized by a periodic structure of peaks in the chronocyclic Wigner function, can outperform standard biphoton states in sensing applications [1].
The Hong-Ou-Mandel interferometer is a versatile tool for analyzing the joint properties of photon pairs, relying on a truly quantum interference effect between two-photon probability amplitudes. While the theory behind this form of two-photon interferometry is well established, the development of advanced photon sources and exotic two-photon states has highlighted the importance of quantifying precisely what information can and cannot be inferred from features in a Hong-Ou-Mandel interference trace. Here we examine Hong-Ou-Mandel interference with regard to a particular class of states, so-called quantum frequency combs, and place special emphasis on the role spectral phase plays in these measurements. We find that this form of two-photon interferometry is insensitive to the relative phase between different comb line pairs. This is true even when different comb line pairs are mutually coherent at the input of a Hong-Ou-Mandel interferometer and the fringe patterns display sharp temporal features. Consequently, Hong-Ou-Mandel interference cannot speak to the presence of high-dimensional frequency-bin entanglement in two-photon quantum frequency combs.
Hong-Ou-Mandel interferometry takes advantage of the quantum nature of two-photon interference to increase the resolution of precision measurements of time-delays. Relying on few-photon probe states, this approach is applicable also in cases of extremely sensible samples and it achieves attosecond (nanometer path length) scale resolution, which is relevant to cell biology and two-dimensional materials. Here, we theoretically analyze how the precision of Hong-Ou-Mandel interferometers can be significantly improved by engineering the spectral distribution of two-photon probe states. In particular, we assess the metrological power of different classes of biphoton states with non-Gaussian time-frequency spectral distributions, considering the estimation of both time-and frequency-shifts. We find that grid states, characterized by a periodic structure of peaks in the chronocyclic Wigner function, can outperform standard biphoton states in sensing applications. The considered states can be feasibly produced with atomic photon sources, bulk non-linear crystals and integrated photonic waveguide devices.
Biphoton frequency comb (BFC), which encompasses multiple discrete frequency modes and represents high-dimensional frequency entanglement, is crucial in quantum information processing due to its high information capacity and error resilience. It also holds significant potential for enhancing timing precision in quantum metrology. Here, we examine quantum metrology timing limits using the BFC as a probe state and derive a quantum Cramér-Rao bound (QCRB) that depends on the mode number, mode spacing, frequency detuning, and single-mode bandwidth. Our results coincide with previous findings that considered only the latter two factors. Under ideal conditions (zero loss and perfect visibility), this bound can be saturated by both spectrally non-resolved Hong-Ou-Mandel (HOM) interferometry at zero delay and spectrally resolved HOM interferometry at arbitrary delays. In practical scenarios, the Fisher information is below the QCRB but can approach its maximum by increasing the mode number and mode spacing for a fixed delay point, suggesting an optimal strategy for improving the precision of HOM-based sensing in practice. Furthermore, compared to spectrally non-resolved measurement, spectrally resolved measurement is a superior strategy due to its higher Fisher information, shorter measurement times, and ambiguity-free dynamic range.
Hong-Ou-Mandel (HOM) interferometry enables delay estimation at the quantum precision limit but is traditionally constrained to path differences within the coherence time of the interfering photons. Here, we demonstrate single-measurement path-delay sensing at the measurement Cramer-Rao bound using spectrally resolved HOM interference, thereby removing the conventional dynamic-range limitation imposed by the photon coherence window, with no scanning required for calibration. By extracting delay information from the spectral interference fringes of spectrally entangled photon pairs, we retain near-optimal sensitivity over an operational range exceeding the photon coherence time by over two orders of magnitude. Using one million detected photon pairs, we achieve a time-delay precision of 20 attosecond (6 nm), while real-time operation (at 1 Hz) yields 330 attosecond (100 nm) precision. Because the estimator relies on fringe periodicity rather than absolute coincidence rates, the method is intrinsically robust to photon losses and variations in interference visibility, eliminating the need for recalibration. As a practical demonstration, we measure the thickness of a 300 um transmissive target with nanometer-scale precision. These results mark a significant step towards deploying quantum-limited measurements in real-world sensing applications using HOM interferometry.