arXiv:2202.07076 · Applied Physics Letters

Collimated versatile atomic beam source with alkali dispensers

Bochao Wei, Alexandra Crawford, Yorick Andeweg, Linzhao Zhuo, Chao Li, Chandra Raman

Published Apr 4, 2022• 7 citations
arXivHTMLPDF

Abstract

Alkali metal dispensers have become an indispensable tool in the production of atomic vapors for magnetometry, alkali vapor cell clocks, and laser cooling experiments. A primary advantage of these dispensers is that they contain alkali metal in an inert form that can be exposed to air without hazard. However, their high temperature of operation (>600 °C) is undesirable for many applications, as it shifts the atomic speed distribution to higher values and presents a radiative heat source that can raise the temperature of its surroundings. For this reason, dispensers are typically not used in line-of-sight applications, such as atomic beam generation. In this work, we present an integrated rubidium dispenser collimating device with a thickness of only 2 mm that produces a beam of atoms traveling primarily in the forward direction. We find that the collimator plate serves to both shield the dispenser's radiation and moderate the velocity of the atomic beam so that the measured longitudinal speed distribution is comparable to that of an ordinary alkali oven at only a slightly elevated temperature of 200 °C. To confirm our theory, we also constructed another compact apparatus consisting of a dispenser and a silicon collimator and the measurements support our conclusion. Our integrated dispenser collimator will particularly be useful in integrated photonics and cavity QED on-chip, where a localized, directed source of Rb vapor in small quantities is needed.

DOI
10.1063/5.0087155

Related papers

Novel rubidium atomic beam with an alkali dispenser source

Timothy Roach, Dwayne Henclewood

We describe a novel atomic beam apparatus with a resistively heated alkali dispenser source and a cold-pumped intermediate chamber. Using laser fluorescence spectroscopy we have measured the atomic density to be 3×1011atoms∕m3 and the total flux to be 5×108atoms∕s in a 0.3cm diameter beam. We have also characterized the velocity distribution of the source based on the Doppler-shifted fluorescence spectrum. The compact geometry, flexibility, and simplicity of the beam may make it useful as an optical frequency reference or for experiments on atom-cooling.

Journal of Vacuum Science & Technology A Vacuum Surfaces and Films•Oct 20, 2004•16 citations

Collimated, single-pass atom source from a pulsed alkali metal dispenser for laser-cooling experiments

Kevin L. Moore, Thomas Purdy, Kater W. Murch +3 more

We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.

arXiv:physics/0409011•Review of Scientific Instruments•Jan 7, 2005•23 citations

Cavity QED in a fully integrated atomic-photonic vapor cell with a pulsed alkali source

Rahul Shrestha, Khoi Tuan Hoang, Peter Riley +5 more

We demonstrate a fully integrated platform for experiments with warm Rb atoms and chip-integrated high-Q (≈ 105) photonic microcavities. Pulsed activation of an alkali dispenser pill enables temperature-independent control of Rb density and resulting cavity interactions.

Conference on Lasers and Electro-Optics•Jan 1, 2025•0 citations

An atomic beam source for fast loading of a magneto-optical trap under high vacuum

Peter D. McDowall, Tzahi Grünzweig, Andrew J. Hilliard +1 more

We report on a directional atomic beam created using an alkali metal dispenser and a nozzle. By applying a high current (15 A) pulse to the dispenser at room temperature we can rapidly heat it to a temperature at which it starts dispensing, avoiding the need for preheating. The atomic beam produced is capable of loading 90% of a magneto-optical trap (MOT) in less than 7 s while maintaining a low vacuum pressure of <10(-11) Torr. The transverse velocity components of the atomic beam are measured to be within typical capture velocities of a rubidium MOT. Finally, we show that the atomic beam can be turned off within 1.8 s.

Review of Scientific Instruments•May 1, 2012•10 citations

Cascaded collimator for atomic beams traveling in planar silicon devices

Chao Li, Xiao Chai, Bochao Wei +4 more

Abstract Micro- and increasingly, nano-fabrication have enabled the miniaturization of atomic devices, from vapor cells to atom chips for Bose-Einstein condensation. Here we present microfabricated planar devices for thermal atomic beams. Etched microchannels were used to create highly collimated, continuous rubidium atom beams traveling parallel to a silicon wafer surface. Precise, lithographic definition of the guiding channels allowed for shaping and tailoring the velocity distributions in ways not possible using conventional machining. Multiple miniature beams with individually prescribed geometries were created, including collimated, focusing and diverging outputs. A “cascaded” collimator was realized with 40 times greater purity than conventional collimators. These localized, miniature atom beam sources can be a valuable resource for a number of quantum technologies, including atom interferometers, clocks, Rydberg atoms, and hybrid atom-nanophotonic systems, as well as enabling controlled studies of atom-surface interactions at the nanometer scale.

APS Division of Atomic, Molecular and Optical Physics Meeting Abstracts•May 1, 2019•0 citations

Cascaded collimator for atomic beams traveling in planar silicon devices

Chao Li, Xiao Chai, Bochao Wei +4 more

Micro- and increasingly, nano-fabrication have enabled the miniaturization of atomic devices, from vapor cells to atom chips for Bose-Einstein condensation. Here we present microfabricated planar devices for thermal atomic beams. Etched microchannels were used to create highly collimated, continuous rubidium atom beams traveling parallel to a silicon wafer surface. Precise, lithographic definition of the guiding channels allowed for shaping and tailoring the velocity distributions in ways not possible using conventional machining. Multiple miniature beams with individually prescribed geometries were created, including collimated, focusing and diverging outputs. A "cascaded" collimator was realized with 40 times greater purity than conventional collimators. These localized, miniature atom beam sources can be a valuable resource for a number of quantum technologies, including atom interferometers, clocks, Rydberg atoms, and hybrid atom-nanophotonic systems, as well as enabling controlled studies of atom-surface interactions at the nanometer scale.

Nature Communications•Apr 23, 2019•33 citations
Alkali metal dispensers have become an indispensable tool in the production of atomic vapors for magnetometry, alkali vapor cell clocks, and laser cooling experiments. A primary advantage of these dispensers is that they contain alkali metal in an inert form that can be exposed to air without hazard. However, their high temperature of operation (>600 °C) is undesirable for many applications, as it shifts the atomic speed distribution to higher values and presents a radiative heat source that can raise the temperature of its surroundings. For this reason, dispensers are typically not used in line-of-sight applications, such as atomic beam generation. In this work, we present an integrated rubidium dispenser collimating device with a thickness of only 2 mm that produces a beam of atoms traveling primarily in the forward direction. We find that the collimator plate serves to both shield the dispenser's radiation and moderate the velocity of the atomic beam so that the measured longitudinal speed distribution is comparable to that of an ordinary alkali oven at only a slightly elevated temperature of 200 °C. To confirm our theory, we also constructed another compact apparatus consisting of a dispenser and a silicon collimator and the measurements support our conclusion. Our integrated dispenser collimator will particularly be useful in integrated photonics and cavity QED on-chip, where a localized, directed source of Rb vapor in small quantities is needed.
We describe a novel atomic beam apparatus with a resistively heated alkali dispenser source and a cold-pumped intermediate chamber. Using laser fluorescence spectroscopy we have measured the atomic density to be 3×1011atoms∕m3 and the total flux to be 5×108atoms∕s in a 0.3cm diameter beam. We have also characterized the velocity distribution of the source based on the Doppler-shifted fluorescence spectrum. The compact geometry, flexibility, and simplicity of the beam may make it useful as an optical frequency reference or for experiments on atom-cooling.
We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.
We report on a directional atomic beam created using an alkali metal dispenser and a nozzle. By applying a high current (15 A) pulse to the dispenser at room temperature we can rapidly heat it to a temperature at which it starts dispensing, avoiding the need for preheating. The atomic beam produced is capable of loading 90% of a magneto-optical trap (MOT) in less than 7 s while maintaining a low vacuum pressure of <10(-11) Torr. The transverse velocity components of the atomic beam are measured to be within typical capture velocities of a rubidium MOT. Finally, we show that the atomic beam can be turned off within 1.8 s.
Abstract Micro- and increasingly, nano-fabrication have enabled the miniaturization of atomic devices, from vapor cells to atom chips for Bose-Einstein condensation. Here we present microfabricated planar devices for thermal atomic beams. Etched microchannels were used to create highly collimated, continuous rubidium atom beams traveling parallel to a silicon wafer surface. Precise, lithographic definition of the guiding channels allowed for shaping and tailoring the velocity distributions in ways not possible using conventional machining. Multiple miniature beams with individually prescribed geometries were created, including collimated, focusing and diverging outputs. A “cascaded” collimator was realized with 40 times greater purity than conventional collimators. These localized, miniature atom beam sources can be a valuable resource for a number of quantum technologies, including atom interferometers, clocks, Rydberg atoms, and hybrid atom-nanophotonic systems, as well as enabling controlled studies of atom-surface interactions at the nanometer scale.
Micro- and increasingly, nano-fabrication have enabled the miniaturization of atomic devices, from vapor cells to atom chips for Bose-Einstein condensation. Here we present microfabricated planar devices for thermal atomic beams. Etched microchannels were used to create highly collimated, continuous rubidium atom beams traveling parallel to a silicon wafer surface. Precise, lithographic definition of the guiding channels allowed for shaping and tailoring the velocity distributions in ways not possible using conventional machining. Multiple miniature beams with individually prescribed geometries were created, including collimated, focusing and diverging outputs. A "cascaded" collimator was realized with 40 times greater purity than conventional collimators. These localized, miniature atom beam sources can be a valuable resource for a number of quantum technologies, including atom interferometers, clocks, Rydberg atoms, and hybrid atom-nanophotonic systems, as well as enabling controlled studies of atom-surface interactions at the nanometer scale.