arXiv:2107.06819 · Optics Express

Electromagnetic induction imaging: signal detection based on tuned-dressed optical magnetometry

G. Bevilacqua, V. Biancalana, Yordanka V. Dancheva, Alessandro Fregosi, Gaetano Napoli, Antonio Vigilante

Published Sep 22, 2021• 0 citations
arXivHTMLPDF

Abstract

A recently introduced tuning-dressed scheme makes a Bell and Bloom magnetometer suited to detect weak variations of a radio-frequency (RF) magnetic field. We envisage the application of such innovative detection scheme as an alternative (or rather as a complement) to RF atomic magnetometers in electromagnetic-induction-imaging apparatuses.

DOI
10.1364/oe.437930

Related papers

Magnetic induction imaging with a cold-atom radio frequency magnetometer

Alessandro Fregosi, C. Gabbanini, S. Gozzini +3 more

The sensitive detection of either static or radio frequency (RF) magnetic fields is essential to many fundamental studies and applications. Here, we demonstrate the operation of a cold-atom-based RF magnetometer in performing 1D and 2D imaging of small metallic objects. It is based on a cold 85Rb atomic sample and operates in an unshielded environment with no active field stabilization. It shows a sensitivity up to 200 pT/Hz in the 5−35 kHz bandwidth range and can resolve a 0.4 mm wide cut in a 0.8 mm thick metallic foil. The characteristics of our system make it a good candidate for applications in civil and industrial surveillance.

arXiv:2010.04437•Applied Physics Letters•Oct 5, 2020•17 citations

Restoring Narrow Linewidth to a Gradient-Broadened Magnetic Resonance by Inhomogeneous Dressing

G. Bevilacqua, V. Biancalana, Yordanka V. Dancheva +1 more

The low-frequency signal from ultralow-field magnetic resonance imaging (ULF-MRI) setups leads to the use of high-sensitivity noninductive detectors. The simplicity and robustness of optical atomic magnetometers (OAMs) make them excellent candidates to this end, but they suffer from magnetic field inhomogeneities. Appropriate magnetic ``dressing'' of precessing atomic spins can overcome this limitation: Applying a dressing field with opportune inhomogeneity compensates the atomic line broadening induced by the MRI gradient, restoring OAM sensitivity and enabling $i\phantom{\rule{0}{0ex}}n$ $s\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}t\phantom{\rule{0}{0ex}}u$ detection of ULF-MRI signals by optical magnetometry.

arXiv:1807.01274•Physical Review Applied•Feb 20, 2019•15 citations

Radio-Frequency Magnetometry Based on Parametric Resonances

Wei Xiao, Xiyu Liu, Teng Wu +2 more

We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.

Physical Review Letters•Aug 27, 2024•25 citations

Free Induction Decay Optically Pumped Magnetometers: A Review

Jiarui Liu, Xiao Liu, Yuantian Lu +4 more

Free induction decay (FID) optically pumped magnetometers are among the most sensitive quantum sensors available for high-precision magnetic field measurements. This review summarizes recent advances in FID magnetometers, which represent a critical technological route that suppresses systematic errors by temporally separating atomic polarization from magnetic field detection. This review covers light-modulated optical pumping schemes (such as the Bell-Bloom mode), radio-frequency excitation schemes, and magnetic-field-enhanced pumping schemes. Key technological developments, including chip-scale MEMS fabrication, optical multipass architectures, advanced frequency estimation algorithms, and error suppression methods, are also discussed. Finally, emerging trends toward higher integration, environmental robustness, and intelligent signal demodulation are highlighted. These trends provide insights into the development of next-generation high-performance quantum sensors and their growing role in biomedical and geophysical applications, as well as in fundamental scientific research.

Sensors•Sep 26, 2026•0 citations

Detection of radio-frequency magnetic fields using nonlinear magneto-optical rotation

M. P. Ledbetter, Víctor M. Acosta, Simon Rochester +3 more

We describe a room-temperature alkali-metal atomic magnetometer for detection of small, high-frequency magnetic fields. The magnetometer operates by detecting optical rotation due to the precession of an aligned ground state in the presence of a small oscillating magnetic field. The resonance frequency of the magnetometer can be adjusted to any desired value by tuning the bias magnetic field. Based on experimentally measured signal-to-noise ratio, we demonstrate a sensitivity of $100\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}$ (rms) in a $3.5\text{\ensuremath{-}}\mathrm{cm}$-diameter paraffin coated cell. Assuming detection at the photon shot-noise limit, we project a sensitivity as low as $25\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}$ (rms).

arXiv:physics/0609196•Physical Review A•Feb 8, 2007•66 citations

Spin-Damping in an Ultra-Sensitive Tunable RF Atomic Magnetometer

Orang Alem

Optically pumped radio frequency (RF) atomic magnetometers have been shown to have an improved sensitivity over standard tuned coils for frequencies less than 50 MHz, making these RF magnetometers attractive for the detection of nuclear quadrupole resonance (NQR) and low-field nuclear magnetic resonance (NMR) signals. In an atomic magnetometer a linearly polarized probe beam measures, through Faraday rotation, the transverse atomic magnetization induced by the resonant RF signal. The resonance, or Larmor, frequency of the magnetometer is easily tuned with a small magnetic field. We construct an atomic magnetometer based on a potassium vapor cell with a measured sensitivity of 0.22 ± 0.02 fT/ √ Hz and a detection bandwidth of 334 ± 11 Hz when tuned to 423 kHz, giving a Q of over 1200. While high Q magnetometers are sensitive to weak magnetic fields, they are also sensitive to magnetic transients, such as those associated with the excitation pulses needed for magnetic resonance. The ringing created by such transients can obscure the signal of interest. This is particularly detrimental for magnetic resonance signals that decay faster than the transverse relaxation rate. We demonstrate that by feeding back part of the optical signal to orthogonal electromagnetic coils, this unwanted ringing can be quickly damped out leaving the magnetometer ready for the detection of the signal. This negative feedback as applied to the K spins is called spin-damping and can be used to relax the K atoms faster by more than two orders of magnitude. Using spin-damping we reduce the dead-time before data acquisition from 0.8 to 0.2 ms in the detection of NQR signals from ammonium nitrate, one of the so-called fertilizer bomb explosives with an NQR frequency of 423 kHz. Furthermore, we discover that spin-damping can not only be used to suppress signals, it can also be used to suppress noise. We show that it can be used to suppress both environmental noise and more fundamental quantum noise, such as photon shot and spin projection noise. The latter suppression opens the door for its use in quantum control to initialize spin systems before measurements. For phase-sensitive detection, as is often used in magnetic resonance, spin-damping suppresses signal and noise in such a way as to increase the sensitivity bandwidth of the magnetometer. We prove, both theoretically and experimentally, that it is possible to increase the magnetometer detection bandwidth by a factor of 3 or more without significant loss in sensitivity. Such gains in bandwidth for a high Q magnetometer translate into savings in detection time, particularly for substance detection where the frequency of the signal of interest may not be completely known.

•Aug 18, 2011•1 citation
A recently introduced tuning-dressed scheme makes a Bell and Bloom magnetometer suited to detect weak variations of a radio-frequency (RF) magnetic field. We envisage the application of such innovative detection scheme as an alternative (or rather as a complement) to RF atomic magnetometers in electromagnetic-induction-imaging apparatuses.
The sensitive detection of either static or radio frequency (RF) magnetic fields is essential to many fundamental studies and applications. Here, we demonstrate the operation of a cold-atom-based RF magnetometer in performing 1D and 2D imaging of small metallic objects. It is based on a cold 85Rb atomic sample and operates in an unshielded environment with no active field stabilization. It shows a sensitivity up to 200 pT/Hz in the 5−35 kHz bandwidth range and can resolve a 0.4 mm wide cut in a 0.8 mm thick metallic foil. The characteristics of our system make it a good candidate for applications in civil and industrial surveillance.
The low-frequency signal from ultralow-field magnetic resonance imaging (ULF-MRI) setups leads to the use of high-sensitivity noninductive detectors. The simplicity and robustness of optical atomic magnetometers (OAMs) make them excellent candidates to this end, but they suffer from magnetic field inhomogeneities. Appropriate magnetic ``dressing'' of precessing atomic spins can overcome this limitation: Applying a dressing field with opportune inhomogeneity compensates the atomic line broadening induced by the MRI gradient, restoring OAM sensitivity and enabling $i\phantom{\rule{0}{0ex}}n$ $s\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}t\phantom{\rule{0}{0ex}}u$ detection of ULF-MRI signals by optical magnetometry.
We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.
Free induction decay (FID) optically pumped magnetometers are among the most sensitive quantum sensors available for high-precision magnetic field measurements. This review summarizes recent advances in FID magnetometers, which represent a critical technological route that suppresses systematic errors by temporally separating atomic polarization from magnetic field detection. This review covers light-modulated optical pumping schemes (such as the Bell-Bloom mode), radio-frequency excitation schemes, and magnetic-field-enhanced pumping schemes. Key technological developments, including chip-scale MEMS fabrication, optical multipass architectures, advanced frequency estimation algorithms, and error suppression methods, are also discussed. Finally, emerging trends toward higher integration, environmental robustness, and intelligent signal demodulation are highlighted. These trends provide insights into the development of next-generation high-performance quantum sensors and their growing role in biomedical and geophysical applications, as well as in fundamental scientific research.
We describe a room-temperature alkali-metal atomic magnetometer for detection of small, high-frequency magnetic fields. The magnetometer operates by detecting optical rotation due to the precession of an aligned ground state in the presence of a small oscillating magnetic field. The resonance frequency of the magnetometer can be adjusted to any desired value by tuning the bias magnetic field. Based on experimentally measured signal-to-noise ratio, we demonstrate a sensitivity of 100pG∕Hz100\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}100pG∕Hz​ (rms) in a $3.5\text{\ensuremath{-}}\mathrm{cm}$-diameter paraffin coated cell. Assuming detection at the photon shot-noise limit, we project a sensitivity as low as 25pG∕Hz25\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}25pG∕Hz​ (rms).
Optically pumped radio frequency (RF) atomic magnetometers have been shown to have an improved sensitivity over standard tuned coils for frequencies less than 50 MHz, making these RF magnetometers attractive for the detection of nuclear quadrupole resonance (NQR) and low-field nuclear magnetic resonance (NMR) signals. In an atomic magnetometer a linearly polarized probe beam measures, through Faraday rotation, the transverse atomic magnetization induced by the resonant RF signal. The resonance, or Larmor, frequency of the magnetometer is easily tuned with a small magnetic field. We construct an atomic magnetometer based on a potassium vapor cell with a measured sensitivity of 0.22 ± 0.02 fT/ √ Hz and a detection bandwidth of 334 ± 11 Hz when tuned to 423 kHz, giving a Q of over 1200. While high Q magnetometers are sensitive to weak magnetic fields, they are also sensitive to magnetic transients, such as those associated with the excitation pulses needed for magnetic resonance. The ringing created by such transients can obscure the signal of interest. This is particularly detrimental for magnetic resonance signals that decay faster than the transverse relaxation rate. We demonstrate that by feeding back part of the optical signal to orthogonal electromagnetic coils, this unwanted ringing can be quickly damped out leaving the magnetometer ready for the detection of the signal. This negative feedback as applied to the K spins is called spin-damping and can be used to relax the K atoms faster by more than two orders of magnitude. Using spin-damping we reduce the dead-time before data acquisition from 0.8 to 0.2 ms in the detection of NQR signals from ammonium nitrate, one of the so-called fertilizer bomb explosives with an NQR frequency of 423 kHz. Furthermore, we discover that spin-damping can not only be used to suppress signals, it can also be used to suppress noise. We show that it can be used to suppress both environmental noise and more fundamental quantum noise, such as photon shot and spin projection noise. The latter suppression opens the door for its use in quantum control to initialize spin systems before measurements. For phase-sensitive detection, as is often used in magnetic resonance, spin-damping suppresses signal and noise in such a way as to increase the sensitivity bandwidth of the magnetometer. We prove, both theoretically and experimentally, that it is possible to increase the magnetometer detection bandwidth by a factor of 3 or more without significant loss in sensitivity. Such gains in bandwidth for a high Q magnetometer translate into savings in detection time, particularly for substance detection where the frequency of the signal of interest may not be completely known.