In quantum communication systems, the precise estimation of the detector´s response to the incoming light is necessary to avoid security breaches. The typical working regime uses a free-running single-photon avalanche diode in combination with attenuated laser pulses at telecom wavelength for encoding information. We demonstrate the validity of an analytical model for this regime that considers the effects of dark counts and dead time on the measured count rate. For the purpose of gaining a better understanding of these effects, the photon detections were separated from the dark counts via a software-induced gating mechanism. The model was verified by experimental data for mean photon numbers covering three orders of magnitude as well as for laser repetition frequencies below and above the inverse dead time. Consequently, our model would be of interest for predicting the detector response not only in the field of quantum communications, but also in any other quantum physics experiment where high detection rates are needed.
In quantum communication systems, the precise estimation of the detector´s response to the incoming light is necessary to avoid security breaches. The typical working regime uses a free-running single-photon avalanche diode in combination with attenuated laser pulses at telecom wavelength for encoding information. We demonstrate the validity of an analytical model for this regime that considers the effects of dark counts and dead time on the measured count rate. For the purpose of gaining a better understanding of these effects, the photon detections were separated from the dark counts via a software-induced gating mechanism. The model was verified by experimental data for mean photon numbers covering three orders of magnitude as well as for laser repetition frequencies below and above the inverse dead time. Consequently, our model would be of interest for predicting the detector response not only in the field of quantum communications, but also in any other quantum physics experiment where high detection rates are needed.
Single-photon detectors are a pivotal component in photonic quantum technologies. A precise and comprehensive calibration of the inherent detection efficiency is of utmost importance to ensure the proper evaluation of the performance in view of the specific technological application of interest, such as the protection against security breaches in quantum cryptographic solutions. Here we report on a systematic study and comprehensive analysis of the estimation of the inherent detection efficiency of two commercial single-photon detectors based on single-photon avalanche diodes for various mean photon numbers and at high laser pulse repetition rates using different techniques. We observe an unexpected and significant drop in the inherent detection efficiency at detection rates of 10% and higher relative to the maximum detection rate. It is demonstrated that for data analysis a statistical model for the detection rate conveniently can be used if no time-stamped data are available. We conclude that the full characterization of single-photon detectors used in critical applications should include the sensitivity of their inherent detection efficiency to high event rates.
With the growing use of online communications in our modern society, information security is becoming a big concern. Along with that, the progress in quantum computers is posing severe threats to such communications. Once powerful quantum computers are available, most of today's encryption schemes, which are based on computationally hard problems, will be broken within a short period. Researchers are therefore making a great effort to establish quantum-safe encryption schemes. One such scheme is quantum key distribution (QKD), which utilizes the laws of quantum mechanics. These cryptography protocols offer unconditional security to the communication between two distant parties by providing a secure way of sharing encryption keys between them. While over the last few decades QKD has continuously progressed, it is limited to a distance of up to several hundred kilometers using terrestrial quantum links. Satellites are therefore being considered to extend the QKD range for global coverage, although implementations of the satellite-based QKD infrastructure are still in their early stage. There are many aspects of QKD that need further assessment and advancement for establishing long-term satellite-based quantum communication (QC). My thesis works were focused on developing advanced systems for single-photon detectors and quantum sources. Single-photon avalanche diodes (SPADs) are the most viable option for satellite-based quantum communications. They must travel to outer space either for receiving quantum-states in the ground-to-satellite QC or for characterizing the quantum-sources in the satellite-to-ground QC. However, while in space, SPADs exhibit damage caused by the space radiation that gradually increases their dark counts. Performing QKD is not possible when the dark counts exceed a specific threshold. Hence, methods of reducing the detectors' dark counts by mitigating the damages would help to extend the SPADs' in-space useful lifetime. Laser annealing is one such effective method, found in lab experiments, to heal the radiation-induced detector damages. We now aim to carry out this method in low Earth orbit (LEO) to verify its in-orbit effectiveness. On that goal, we are building an annealing payload (APL) for a cube satellite (CubeSat) in collaboration with the University of Illinois at Urbana Champaign (UIUC). We, the University of Waterloo team, built one of the two segments of the APL-- a space-qualified detector module containing two Excelitas C30902SH and Excelitas SLiK detectors. Our miniaturized and compact module integrates the facilities required for the detector operation and laser annealing, as well as an active detector temperature control system. The operation of the detector module is highly flexible and software controllable. Our detector module will work together with the control board containing the laser annealing system (built by the UIUC team). Once the satellite has been launched in 2020, the in-orbit experiment will enable us to study the in-space SPAD radiation damage and their healing using the integrated annealing system. During a second project, we designed and built a new simple readout circuit for the negative feedback avalanche diodes (NFADs), which are free-running single-photon detectors at telecom wavelengths. These detectors suffer from strong afterpulsing effects, which limits their overall performances. Therefore, our readout system incorporates features to suppress NFAD afterpulses. We also used this custom readout to characterize two NFADs (from Princeton Lightwave) and assessed the performance of the new electronics. Our analysis showed that even at higher detection efficiencies, a 20 mus hold-off time after each avalanche event is enough to extensively reduce the number of afterpulses and to keep the dark count rate below 100 Hz at 192 K temperature. Both the detectors showed timing jitter of less than 75 ps FWHM at their maximum efficiencies. The best figure of merit is found to be 1.6times107, which is comparable to that of the high-performing superconducting nanowire single-photon detectors. This result demonstrates the suitability of our readout and the NFADs in various quantum optics applications, such as in long-distance quantum key distribution, where the detection rate is usually low. We then performed a blinding attack, which enables an Eavesdropper in QKD to gain information on the key, on these NFADs using bright illumination. These detectors are usually threshold detectors that generate a click when the optical power is above a certain threshold, otherwise they do not click. Blinding attack utilizes detectors' inability to resolve the photon numbers. During the experiment, we sent controlled optical pulses with a high time resolution to deterministically force detection at the detectors. The result demonstrated the NFADs' susceptibility to these attacks, which tells us to include countermeasures into the system to protect the communications. Finally, we built a quantum source to produce 785 nm polarized photons to implement decoy-state BB84 QKD. Our source utilized the sum-frequency generation scheme to generate 785 nm laser pulses. Its modulator system includes an intensity modulator and two-phase modulators in the Mach-Zehnder configuration to prepare polarized quantum states with different intensities. Our source provides a repetition rate of 500 MHz, which was successfully used in an airborne QKD demonstration with a moving receiver up to 10km distance. To summarize, my research projects are a contribution to the development of advanced devices, particularly single-photon detectors for quantum communications.
We measure the nonlinearity of a telecom-wavelength superconducting nanowire single-photon detector via incoherent beam combination. At typical photon count rates and detector bias current, the observed relative deviation from a perfectly linear response is in the order of 0.1% when the flux is doubled. This arises from a balance between the counteracting nonlinearities of dead time-induced detector saturation and of multi-photon detections. The observed behavior is modeled empirically, which suffices for a correction of measured data. In addition, statistical simulations, taking into account the measured recovery of the detection efficiency (90%-recovery after about 100 ns), provide insight into possible mechanisms of multi-photon detection.
Two approaches to single-photon detection at telecom wavelengths have been investigated, using semiconductor and superconductor technologies. The low temperature operation of free-running InGaAs/InP negative feedback avalanche diodes (NFADs) was studied, demonstrating that they can operate with an extremely low dark count rate, which opens up a host of new applications. Secondly, superconducting nanowire single-photon detectors (SNSPDs) based on amorphous materials were developed, fabricated and characterized. These detectors are highly attractive because they can achieve excellent attributes simultaneously, such as high efficiency, low noise, good temporal resolution, no afterpulsing and high count rates. Finally, it was demonstrated that the use of NFADs can enable record distance quantum key distribution (QKD) over 307 km of optical fiber. A next generation QKD system has been proposed and numerically analyzed, aiming at extending the record distance by an additional 100 km and increasing the state-of-the-art secret key rate by over an order of magnitude.
InGaAs/InP single-photon detectors are today the most frequently used detectors for fibre-based Quantum Key Distribution (QKD) [1,2]. The performance of the QKD-systems greatly depends on the optical properties of its detector, such as quantum efficiency, dead time, dark counts, gating rate, etc., which need to be metrologically characterized to fully grantee the QKD network security. Therefore, several European National Metrological Institutes (NMIs) are putting today great efforts in developing novel measurement methods and calibration facilities, which allow to perform the traceable characterisation of single-photon detectors by using reference standards [3, 4]. From the metrological, and specifically radiometric, point of view, the detection efficiency of the single-photon detector is the main parameter that needs to be traceable to the primary standard for optical power (i.e. the cryogenic radiometer), which is maintained by most of the NMIs. Recently, four European NMIs have carried out a pilot comparison on the detection efficiency of a free-running InGaAs/InP single-photon detector, which main purpose has been to provide a snapshot of the measurement capabilities of the four European NMIs in the field of photon counting detection. The comparison was carried out in the framework of the EMPIR project 14IND05 “Optical metrology for quantum-enhanced secure telecommunication (MIQC2)” at the telecom wavelength of 1550 nm by using different reference standards with independently traceability chains. The results of this comparison, including the different experimental setups, the measurement methods, the traceability chain and the uncertainty evaluation of each participant, will be presented in this conference. References: [1] Akihisa Tomita, et al., “High speed quantum key distribution system”, Optical Fiber Technology, 16, Issue 1, 55-62 (2010). [2] Damien Stucki, et al., “Photon counting for quantum key distribution with peltier cooled InGaAs/InP APDs”, Journal of Modern Optics, 48, Issue 13, 1967-1981 (2001). [3] M. López, et al, “Detection efficiency calibration of single-photon silicon avalanche photodiodes traceable using double attenuator technique, Journal of Modern Optics 62, S21 – S27, 2015. [4] G. Porrovecchio, et al., “Comparison at the sub-100 fW optical power level of calibrating a single-photon detector using a high-sensitive, low-noise silicon photodiode and the double attenuator technique”, Metrologia 53, 1115-1122 (2016).
In light of the growing widely utilized single-photon avalanche detectors, dead time is inevitable due to the presence of afterpulse. Dead time is a critical factor that influences the count rate and the secret key rate (SKR) of quantum key distribution (QKD). It is particularly significant in time-bin-encoding systems, while prior models fail to accurately estimate the gains. Of note, it introduces correlations between early bins and late bins, hence bits with strong correlation and security risks. Here, we put forward a realistic model that precisely characterizes the response of detectors for time-bin-encoding systems. Our model not only improves the accuracy of gain predictions, showing an excellent match with the Monte Carlo simulation results, but also provides theoretical support for data processing, helping to mitigate security risks. Finally, leveraging our model, we can get a much higher SKR than prior models and further enhance the performance of practical QKD systems by adjusting the detector parameters. Our simulation results demonstrate that our model is essential for the application and deployment of QKD systems in practice.