arXiv:2103.10833 · Physical Review Research

Effects of coherence on temporal resolution

Syamsundar De, Jano Gil-Lopez, Benjamin Brecht, Christine Silberhorn, Luis Lorenzo Sánchez-Soto, Z. Hradil, Jaroslav Řeháček

Published Jul 22, 2021• 21 citations
arXivHTMLPDF

Abstract

Measuring small separations between two optical sources, either in space or in time, constitutes an important metrological challenge as standard intensity-only measurements fail for vanishing separations. Contrarily, it has been established that appropriate coherent mode projections can appraise arbitrarily small separations with quantum-limited precision. However, the question of whether the optical coherence brings any metrological advantage to mode projections is still a point of debate. Here, we elucidate this problem by experimentally investigating the effect of varying coherence on estimating the temporal separation between two single-photon pulses. We show that, for an accurate interpretation, special attention must be paid to properly normalize the quantum Fisher information to account for the strength of the signal.

DOI
10.1103/physrevresearch.3.033082

Related papers

Achieving the ultimate optical resolution

Luis Lorenzo Sánchez-Soto, Z. Hradil, Jaroslav Řeháček +2 more

The accurate estimation of the separation between two signals is at the core of many modern technologies. We show new quantum-inspired schemes able to estimate that separation at the quantum limit. The method works in the spatial, temporal, and frequency domains. The question of whether the optical coherence brings any metrological advantage to mode projections is discussed.

EPJ Web of Conferences•Jan 1, 2022•0 citations

Quantum Fisher information with coherence

Z. Hradil, Jaroslav Řeháček, Luis Sánchez-Soto +1 more

In recent proposals for achieving optical super-resolution, variants of the Quantum Fisher Information (QFI) quantify the attainable precision. We find that claims about a strong enhancement of the resolution resulting from coherence effects are questionable because they refer to very small subsets of the data without proper normalization. When the QFI is normalized, accounting for the strength of the signal, there is no advantage of coherent sources over incoherent ones. Our findings have a bearing on further studies of the achievable precision of optical instruments.

arXiv:1910.10265•Optica•Nov 12, 2019•54 citations

Quantum-limited time-frequency estimation through mode-resolved measurements

Vahid Ansari, John M. Donohue, Jaroslav Řeháček +5 more

We employ time-frequency projective measurements to estimate arbitrarily small separations between objects with quantum-limited precision. We experimentally resolve temporal and spectral separations between incoherent mixtures of single-photon level signals ten times smaller than their bandwidths.

Quantum Information and Measurement (QIM)•Jan 1, 2019•0 citations

Temporal Resolution of Partially Coherent Sources

Syamsundar De, Jano Gil-López, Benjamin Brecht +4 more

In spatial imaging, it is well known that two incoherent sources with a separation less than the diffraction limit cannot be resolved, a phenomenon dubbed as Rayleigh’s curse. A recent information theoretic approach suggests that this curse can be avoided using optimal (here, mode-sensitive) measurements instead of the usual intensity-only measurements, which define the classical limit [1] . This quantum enhanced resolution has been realized in both the spatial [2] and temporal domain [3] . Nevertheless, the role of optical coherence on the resolution limit still remains elusive [4] , [5] , [6] . Here, we experimentally resolve this debate using time-domain measurements.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 21, 2021•0 citations

Quantum-Limited Time-Frequency Estimation through Mode-Selective Photon Measurement

John M. Donohue, Vahid Ansari, Jaroslav Řeháček +5 more

By projecting onto complex optical mode profiles, it is possible to estimate arbitrarily small separations between objects with quantum-limited precision, free of uncertainty arising from overlapping intensity profiles. Here we extend these techniques to the time-frequency domain using mode-selective sum-frequency generation with shaped ultrafast pulses. We experimentally resolve temporal and spectral separations between incoherent mixtures of single-photon level signals ten times smaller than their optical bandwidths with a tenfold improvement in precision over the intensity-only Cramér-Rao bound.

arXiv:1805.02491•Physical Review Letters•Aug 27, 2018•98 citations

Quantum-limited resolution of partially coherent sources

Ben Wang, Liang Xu, Hongkuan Xia +3 more

Discriminating two spatially separated sources is one of the most fundamental problems in imaging.Recent research based on quantum parameter estimation theory shows that the resolution limit of two incoherent point sources given by Rayleigh can be broken.However, in realistic optical systems, there often exists coherence in the imaging light field, and there have been efforts to analyze the optical resolution in the presence of partial coherence.Nevertheless, how the degree of coherence between two point sources affects the resolution has not been fully understood.Here, we analyze the quantum-limited resolution of two partially coherent point sources by explicitly relating the state after evolution through the optical systems to the coherence of the sources.In particular, we consider the situation in which coherence varies with the separation.We propose a feasible experiment scheme to realize the nearly optimal measurement, which adaptively chooses the binary spatial-mode demultiplexing measurement and direct imaging.Our results will have wide applications in imaging involving coherence of light.

Chinese Optics Letters•Jan 1, 2023•6 citations
Measuring small separations between two optical sources, either in space or in time, constitutes an important metrological challenge as standard intensity-only measurements fail for vanishing separations. Contrarily, it has been established that appropriate coherent mode projections can appraise arbitrarily small separations with quantum-limited precision. However, the question of whether the optical coherence brings any metrological advantage to mode projections is still a point of debate. Here, we elucidate this problem by experimentally investigating the effect of varying coherence on estimating the temporal separation between two single-photon pulses. We show that, for an accurate interpretation, special attention must be paid to properly normalize the quantum Fisher information to account for the strength of the signal.
In recent proposals for achieving optical super-resolution, variants of the Quantum Fisher Information (QFI) quantify the attainable precision. We find that claims about a strong enhancement of the resolution resulting from coherence effects are questionable because they refer to very small subsets of the data without proper normalization. When the QFI is normalized, accounting for the strength of the signal, there is no advantage of coherent sources over incoherent ones. Our findings have a bearing on further studies of the achievable precision of optical instruments.
In spatial imaging, it is well known that two incoherent sources with a separation less than the diffraction limit cannot be resolved, a phenomenon dubbed as Rayleigh’s curse. A recent information theoretic approach suggests that this curse can be avoided using optimal (here, mode-sensitive) measurements instead of the usual intensity-only measurements, which define the classical limit [1] . This quantum enhanced resolution has been realized in both the spatial [2] and temporal domain [3] . Nevertheless, the role of optical coherence on the resolution limit still remains elusive [4] , [5] , [6] . Here, we experimentally resolve this debate using time-domain measurements.
By projecting onto complex optical mode profiles, it is possible to estimate arbitrarily small separations between objects with quantum-limited precision, free of uncertainty arising from overlapping intensity profiles. Here we extend these techniques to the time-frequency domain using mode-selective sum-frequency generation with shaped ultrafast pulses. We experimentally resolve temporal and spectral separations between incoherent mixtures of single-photon level signals ten times smaller than their optical bandwidths with a tenfold improvement in precision over the intensity-only Cramér-Rao bound.
Discriminating two spatially separated sources is one of the most fundamental problems in imaging.Recent research based on quantum parameter estimation theory shows that the resolution limit of two incoherent point sources given by Rayleigh can be broken.However, in realistic optical systems, there often exists coherence in the imaging light field, and there have been efforts to analyze the optical resolution in the presence of partial coherence.Nevertheless, how the degree of coherence between two point sources affects the resolution has not been fully understood.Here, we analyze the quantum-limited resolution of two partially coherent point sources by explicitly relating the state after evolution through the optical systems to the coherence of the sources.In particular, we consider the situation in which coherence varies with the separation.We propose a feasible experiment scheme to realize the nearly optimal measurement, which adaptively chooses the binary spatial-mode demultiplexing measurement and direct imaging.Our results will have wide applications in imaging involving coherence of light.