Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2103.08168 · Physical Review A

Nonlinear magnetoelectric effect in atomic vapor and its application to precision radio-frequency magnetometry

Sushree S. Sahoo, Soumya R. Mishra, G Rajalakshmi, Ashok Kumar Mohapatra

Published Jun 13, 2022• 4 citations
arXivHTMLPDF

Abstract

We demonstrate the nonlinear magnetoelectric (ME) effect in atomic vapor achieved through the parametric interaction of optical electric and radio-frequency (rf) magnetic fields leading to the generation of new optical electric fields. Density matrix calculations are performed to validate the experimental results. Moreover, the predicted dependence of the generated optical electric field amplitudes on the rf magnetic field strength is experimentally verified to confirm the ME effect. The system provides a technique for precision rf magnetometry based on this phenomenon. We could experimentally achieve an rf magnetic field sensitivity of 70 $\mathrm{fT}/\sqrt{\text{Hz}}$ at 1 kHz to 7.5 $\mathrm{pT}/\sqrt{\text{Hz}}$ at 3 MHz for zero bias field in an unshielded environment. The appealing features of the proposed rf magnetometer using our system include a high dynamic range up to ${10}^{12}$, 6 dB bandwidth of 450 kHz, and arbitrary frequency resolution, which are intrinsic to the nonlinear ME effect in the medium.

DOI
10.1103/physreva.105.063509

Related papers

Reconfigurable circular polarization medium frequency atomic receiver using magneto-electric effect

Sujit Garain, Surya Narayan Sahoo, Ashok Kumar Mohapatra

Nonlinear magnetoelectric effect(NME) in alkali atomic vapor has applications in precision magnetometry in the radio-frequency domain. We report the application of the NME in alkali atomic vapors for projective measurement of medium-frequency (MF) magnetic fields in a circular basis with an extinction ratio up to 500:1 . Utilizing a longitudinal static magnetic field, we demonstrate a high-sensitivity technique for characterizing the ellipticity of radio-frequency (RF) magnetic fields which can in turn be used for phase sensitive detection in mid frequency communication. Additionally, we demonstrate the conversion of binary phase shift keyed RF magnetic fields into amplitude modulation of generated optical fields, a versatile receiver for communication using the medium frequency band.

arXiv:2408.10398•Aug 19, 2024•0 citations

Magnetometry using hot atomic vapors

Martín Romero, Fernando

We demonstrate an ultra-high sensitivity rf optical magnetometer based on a compact 5×5×8 mm3 Rubidium-87 vapor cell in a mu-metal shielded environment. The rf field is detected via a Faraday rotation effect on the linear polarization of a probe beam, and the resonance frequency is tuned via Zeeman effect by applying a static bias magnetic field to the cell. Sensitivities down to 3 fT/√Hz are achieved between 10 kHz and 100 kHz, which is a performance comparable to that of prior larger cells. An increase in the sensitivity with frequency and temperature has been observed.

•Jul 19, 2022•0 citations

Radio-Frequency Magnetometry Based on Parametric Resonances

Wei Xiao, Xiyu Liu, Teng Wu +2 more

We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.

Physical Review Letters•Aug 27, 2024•25 citations

Single-Beam Room-Temperature Atomic Magnetometer with Large Bandwidth and Dynamic Range

K. K. George Kurian, Sushree S. Sahoo, Perunthiruthy K. Madhu +1 more

We present a single-beam atomic magnetometer operating at room temperature for the measurement of ac magnetic fields. The magnetometer functions in the nonlinear regime of magneto-optical rotation of ${}^{85}\mathrm{Rb}$ atomic vapor without any buffer gases. We demonstrate a sensitivity of approximately $0.9\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}$ at 2 kHz and a large bandwidth of 24 kHz. The dynamic range of measurement is ${10}^{6}$, making the sensor effective even in Earth's field. We present the signal-to-noise and bandwidth characteristics of the system for both shielded and unshielded modes of operation. Moreover, we perform theoretical analysis for the atom-light system for the single-laser-beam configuration. The effect of light intensity and detuning on the magnetometer is studied theoretically as well as experimentally to understand the strengths and limitations of the technique.

arXiv:2209.04249•Physical Review Applied•May 11, 2023•13 citations

All-Optical Parametric-Resonance Magnetometer Based on 4He Atomic Alignment

Bowen Wang, Xiang Peng, Haidong Wang +2 more

Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.

Sensors•May 31, 2022•4 citations

All-optical vector atomic magnetometer

E. Zhivun, Brian Patton, Chris Hovde +1 more

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.

Bulletin of the American Physical Society•Jun 5, 2014•24 citations
We demonstrate the nonlinear magnetoelectric (ME) effect in atomic vapor achieved through the parametric interaction of optical electric and radio-frequency (rf) magnetic fields leading to the generation of new optical electric fields. Density matrix calculations are performed to validate the experimental results. Moreover, the predicted dependence of the generated optical electric field amplitudes on the rf magnetic field strength is experimentally verified to confirm the ME effect. The system provides a technique for precision rf magnetometry based on this phenomenon. We could experimentally achieve an rf magnetic field sensitivity of 70 fT/Hz\mathrm{fT}/\sqrt{\text{Hz}}fT/Hz​ at 1 kHz to 7.5 pT/Hz\mathrm{pT}/\sqrt{\text{Hz}}pT/Hz​ at 3 MHz for zero bias field in an unshielded environment. The appealing features of the proposed rf magnetometer using our system include a high dynamic range up to 1012{10}^{12}1012, 6 dB bandwidth of 450 kHz, and arbitrary frequency resolution, which are intrinsic to the nonlinear ME effect in the medium.
Nonlinear magnetoelectric effect(NME) in alkali atomic vapor has applications in precision magnetometry in the radio-frequency domain. We report the application of the NME in alkali atomic vapors for projective measurement of medium-frequency (MF) magnetic fields in a circular basis with an extinction ratio up to 500:1 . Utilizing a longitudinal static magnetic field, we demonstrate a high-sensitivity technique for characterizing the ellipticity of radio-frequency (RF) magnetic fields which can in turn be used for phase sensitive detection in mid frequency communication. Additionally, we demonstrate the conversion of binary phase shift keyed RF magnetic fields into amplitude modulation of generated optical fields, a versatile receiver for communication using the medium frequency band.
We demonstrate an ultra-high sensitivity rf optical magnetometer based on a compact 5×5×8 mm3 Rubidium-87 vapor cell in a mu-metal shielded environment. The rf field is detected via a Faraday rotation effect on the linear polarization of a probe beam, and the resonance frequency is tuned via Zeeman effect by applying a static bias magnetic field to the cell. Sensitivities down to 3 fT/√Hz are achieved between 10 kHz and 100 kHz, which is a performance comparable to that of prior larger cells. An increase in the sensitivity with frequency and temperature has been observed.
We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.
We present a single-beam atomic magnetometer operating at room temperature for the measurement of ac magnetic fields. The magnetometer functions in the nonlinear regime of magneto-optical rotation of 85Rb{}^{85}\mathrm{Rb}85Rb atomic vapor without any buffer gases. We demonstrate a sensitivity of approximately 0.9pT/Hz0.9\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}0.9pT/Hz​ at 2 kHz and a large bandwidth of 24 kHz. The dynamic range of measurement is 106{10}^{6}106, making the sensor effective even in Earth's field. We present the signal-to-noise and bandwidth characteristics of the system for both shielded and unshielded modes of operation. Moreover, we perform theoretical analysis for the atom-light system for the single-laser-beam configuration. The effect of light intensity and detuning on the magnetometer is studied theoretically as well as experimentally to understand the strengths and limitations of the technique.
Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.