Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2102.07212 · Physical Review A

Continuous real-time sensing with a nitrogen-vacancy center via coherent population trapping

Shu-Hao Wu, Ethan Turner, Hailin Wang

Published Apr 12, 2021• 18 citations
arXivHTMLPDF

Abstract

We propose and theoretically analyze the use of coherent population trapping of a single diamond nitrogen-vacancy (NV) center for continuous real-time sensing. The formation of the dark state in coherent population trapping prevents optical emissions from the NV center. Fluctuating magnetic fields, however, can kick the NV center out of the dark state, leading to a sequence of single-photon emissions. A time series of the photon counts detected can be used for magnetic field estimations, even when the average photon count per update time interval is much smaller than 1. For a theoretical demonstration, the nuclear spin bath in a diamond lattice is used as a model fluctuating magnetic environment. For fluctuations with known statistical properties, such as an Ornstein-Uhlenbeck process, Bayesian inference-based estimators can lead to an estimation variance that approaches the classical Cramer-Rao lower bound and can update dynamical information in real time with the detection of just a single photon. Real-time sensing using coherent population trapping adds a powerful tool to the emerging technology of quantum sensing.

DOI
10.1103/physreva.103.042607

Related papers

Real-time magnetometry with coherent population trapping in a nitrogen-vacancy center

Ethan Turner, Shu-Hao Wu, Xinzhu Li +1 more

We demonstrate real-time magnetometry by detecting fluorescence from a nitrogen-vacancy center in the setting of coherent population trapping and by estimating the magnetic field from the time series of the observed photon counts, which are correlated with the underlying field variation. The proof-of-principle experiment uses an external time-varying magnetic field that follows an Ornstein-Uhlenbeck (OU) process. A conventional estimator based on the use of average photon counts per relevant time interval is susceptible to photon number shot noise and performs poorly at relatively low average photon counts. In comparison, by taking into consideration the statistical properties of the OU process, a Bayesian inference-based estimator can effectively update dynamical information of the field in real time with the detection of just a single photon.

arXiv:2111.09943•Physical Review A•Jan 20, 2022•12 citations

Spin-based continuous Bayesian magnetic-field estimations aided by feedback control

Ethan Turner, Shu-Hao Wu, Xinzhu Li +1 more

We demonstrate continuous real-time Bayesian estimations of magnetic-field fluctuations by monitoring single-photon emissions from a diamond nitrogen vacancy center under the setting of coherent population trapping, for which the time sequence of the single-photon emissions is correlated with the underlying magnetic-field fluctuations. The Bayesian estimations are combined with a feedback loop and are followed by a separate verification and optimization process, which uses the spin-dephasing rate in the presence of the feedback as a cost function. The dephasing rate is measured with Ramsey interferometry and is minimized by systematically varying the statistical parameters used in the estimations. The Bayesian estimations aided by the feedback and verification enable continuous real-time sensing at the single-photon level regardless of the prior availability of the statistical parameters of the underlying dynamics.

Physical Review A•Nov 7, 2022•9 citations

Real-time magnetometry via coherent population trapping in a nitrogen vacancy center

Hailin Wang

We report the experimental demonstration of real-time magnetometry by detecting fluorescence from a nitrogen vacancy center in the setting of coherent population trapping and by estimating magnetic fields from the time series of the observed photon counts. We show that by taking into consideration the statistical properties of magnetic field fluctuations, a Bayesian inference-based estimator can effectively update dynamical information of the field in real time with the detection of just a single photon.

Optical and Quantum Sensing and Precision Metrology II•Mar 9, 2022•0 citations

Nitrogen vacancies (NV) centers in diamond for magnetic sensors and quantum sensing

Mayeul Chipaux, Stéphane Xavier, Alexandre Tallaire +6 more

Nitrogen Vacancy (NV) centers are point defects in diamond that allow magnetic field sensing based on Optically Detected Magnetic Resonance (ODMR). They are processed in ultrapure single-domain CVD grown diamond crystals and can be operated at room temperature. This results in solid-state sensors with a wide variety of applications. Ensemble of NV centers can be used to perform wide-field magnetic imaging with sensitivity in the nT range. Single NV centers can also be processed, which allows sensing at the atomic scale. This possibility, combined with its unique coherence properties, make NV center an ideal candidate for quantum sensing.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 8, 2015•3 citations

Nitrogen Vacancy Centers in Diamond for Quantum Biosensing: Magnetometry Techniques, Platforms and Applications

Sirsendu Ghosal, Umakant Prajapati, Sachin Negi +3 more

Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.

quant-pharXiv:2609.04733•Sep 7, 2026

Efficient Real-Time Spin Readout of Nitrogen-Vacancy Centers Based on Bayesian Estimation

Jixing Zhang, Tianzheng Liu, Heng Yuan +8 more

This article introduces a real-time Bayesian estimation algorithm aimed at enhancing the spin readout efficiency of the nitrogen vacancy (NV) center ensemble in the diamond. By integrating both the prior probability distribution and the fluorescence likelihood function, stemming from the implementation of the NV center dynamics model, we offered an innovative solution to surpass the Cramer–Rao lower bound of the readout variance and improve the readout efficiency. The proposed real-time Bayesian estimation readout algorithm was experimentally realized by combining high-performance acquisition and processing hardware, and the Rabi oscillation experiments divulged that the signal-to-noise ratio of our approach was improved by 28.6%. This research illustrates the potential of the Bayesian estimation readout to enhance the NV ensemble's sensing capabilities and support the development of compact and scalable quantum sensors devices on a monolithic platform.

arXiv:2302.06310•IEEE Transactions on Industrial Electronics•Jan 24, 2024•8 citations
We propose and theoretically analyze the use of coherent population trapping of a single diamond nitrogen-vacancy (NV) center for continuous real-time sensing. The formation of the dark state in coherent population trapping prevents optical emissions from the NV center. Fluctuating magnetic fields, however, can kick the NV center out of the dark state, leading to a sequence of single-photon emissions. A time series of the photon counts detected can be used for magnetic field estimations, even when the average photon count per update time interval is much smaller than 1. For a theoretical demonstration, the nuclear spin bath in a diamond lattice is used as a model fluctuating magnetic environment. For fluctuations with known statistical properties, such as an Ornstein-Uhlenbeck process, Bayesian inference-based estimators can lead to an estimation variance that approaches the classical Cramer-Rao lower bound and can update dynamical information in real time with the detection of just a single photon. Real-time sensing using coherent population trapping adds a powerful tool to the emerging technology of quantum sensing.
We demonstrate real-time magnetometry by detecting fluorescence from a nitrogen-vacancy center in the setting of coherent population trapping and by estimating the magnetic field from the time series of the observed photon counts, which are correlated with the underlying field variation. The proof-of-principle experiment uses an external time-varying magnetic field that follows an Ornstein-Uhlenbeck (OU) process. A conventional estimator based on the use of average photon counts per relevant time interval is susceptible to photon number shot noise and performs poorly at relatively low average photon counts. In comparison, by taking into consideration the statistical properties of the OU process, a Bayesian inference-based estimator can effectively update dynamical information of the field in real time with the detection of just a single photon.
We demonstrate continuous real-time Bayesian estimations of magnetic-field fluctuations by monitoring single-photon emissions from a diamond nitrogen vacancy center under the setting of coherent population trapping, for which the time sequence of the single-photon emissions is correlated with the underlying magnetic-field fluctuations. The Bayesian estimations are combined with a feedback loop and are followed by a separate verification and optimization process, which uses the spin-dephasing rate in the presence of the feedback as a cost function. The dephasing rate is measured with Ramsey interferometry and is minimized by systematically varying the statistical parameters used in the estimations. The Bayesian estimations aided by the feedback and verification enable continuous real-time sensing at the single-photon level regardless of the prior availability of the statistical parameters of the underlying dynamics.
We report the experimental demonstration of real-time magnetometry by detecting fluorescence from a nitrogen vacancy center in the setting of coherent population trapping and by estimating magnetic fields from the time series of the observed photon counts. We show that by taking into consideration the statistical properties of magnetic field fluctuations, a Bayesian inference-based estimator can effectively update dynamical information of the field in real time with the detection of just a single photon.
Nitrogen Vacancy (NV) centers are point defects in diamond that allow magnetic field sensing based on Optically Detected Magnetic Resonance (ODMR). They are processed in ultrapure single-domain CVD grown diamond crystals and can be operated at room temperature. This results in solid-state sensors with a wide variety of applications. Ensemble of NV centers can be used to perform wide-field magnetic imaging with sensitivity in the nT range. Single NV centers can also be processed, which allows sensing at the atomic scale. This possibility, combined with its unique coherence properties, make NV center an ideal candidate for quantum sensing.
Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.
This article introduces a real-time Bayesian estimation algorithm aimed at enhancing the spin readout efficiency of the nitrogen vacancy (NV) center ensemble in the diamond. By integrating both the prior probability distribution and the fluorescence likelihood function, stemming from the implementation of the NV center dynamics model, we offered an innovative solution to surpass the Cramer–Rao lower bound of the readout variance and improve the readout efficiency. The proposed real-time Bayesian estimation readout algorithm was experimentally realized by combining high-performance acquisition and processing hardware, and the Rabi oscillation experiments divulged that the signal-to-noise ratio of our approach was improved by 28.6%. This research illustrates the potential of the Bayesian estimation readout to enhance the NV ensemble's sensing capabilities and support the development of compact and scalable quantum sensors devices on a monolithic platform.