Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2102.01415 · Nature

Detecting spins by their fluorescence with a microwave photon counter

Emanuele Albertinale, Léo Balembois, Eric Billaud, V. Ranjan, D. Flanigan, Thomas Schenkel, Daniel Estève, D. Vion, Patrice Bertet, Emmanuel Flurin

Published Dec 15, 2021• 64 citations
arXivHTMLPDF
DOI
10.1038/s41586-021-04076-z

Related papers

Single-electron spin resonance detection by microwave photon counting

Z. Wang, Léo Balembois, Miloš Rančić +10 more

arXiv:2301.02653•Nature•Jul 12, 2023•111 citations

Enhancing the sensitivity of single-microwave-photon detection with bandwidth tunability

L. Pallegoix, J. Travesedo, Alexandre S. May +4 more

We report on the characteristics of a microwave photon-counter device based on a superconducting transmon qubit. Its design is similar to that described by Balembois [], which achieved a sensitivity of 10 − 22 W / Hz , but with an additional bandwidth-tuning circuit that permits tuning the detection bandwidth over an order of magnitude to optimize the efficiency and noise level of the device. As a result of this feature and improvements in device fabrication, a power sensitivity of 3 × 10 − 23 W / Hz is reached. We confirm the high performance of the device by measuring single-spin microwave fluorescence.

arXiv:2501.07354•Physical Review Applied•Nov 10, 2025•9 citations

Microwave Fluorescence Detection of Spin Echoes

Eric Billaud, Léo Balembois, Marianne Le Dantec +9 more

Counting the microwave photons emitted by an ensemble of electron spins when they relax radiatively has recently been proposed as a sensitive method for electron paramagnetic resonance spectroscopy, enabled by the development of operational single microwave photon detectors at millikelvin temperature. Here, we report the detection of spin echoes in the spin fluorescence signal. The echo manifests itself as a coherent modulation of the number of photons spontaneously emitted after a $\ensuremath{\pi}/{2}_{X}\ensuremath{-}\ensuremath{\tau}\ensuremath{-}{\ensuremath{\pi}}_{Y}\ensuremath{-}\ensuremath{\tau}\ensuremath{-}\ensuremath{\pi}/{2}_{\mathrm{\ensuremath{\Phi}}}$ sequence, dependent on the relative phase $\mathrm{\ensuremath{\Phi}}$. We demonstrate experimentally this detection method using an ensemble of ${\mathrm{Er}}^{3+}$ ion spins in a scheelite crystal of ${\mathrm{CaWO}}_{4}$. We use fluorescence-detected echoes to measure the erbium spin coherence time, as well as the echo envelope modulation due to the coupling to the $^{183}\mathrm{W}$ nuclear spins surrounding each ion. We finally compare the signal-to-noise ratio of inductively detected and fluorescence-detected echoes, and show that it is larger with the fluorescence method.

arXiv:2208.13586•Physical Review Letters•Sep 8, 2023•20 citations

Efficient Detection of Microwave Photons

Anonymous

Physics•May 18, 2020•0 citations

Single electron-spin-resonance detection by microwave photon counting

Steven Steven

1. Single electron-spin-resonance detection by microwave photon counting Authors: Z. Wang, L. Balembois, M. M. Rančić, E. Billaud, M. Le Dantec, A. Ferrier, P. Goldner, S. Bertaina, T. Chanelière, D. Estève, D. Vion, P. Bertet, and E. Flurin Nature 619, 276–281 (2023); DOI: 10.1038/s41586-023-06097-2 2. Practical Single Microwave Photon Counter with 10-22 W/√Hz sensitivity Authors: […]

Journal Club for Condensed Matter Physics•Aug 29, 2023•1 citation

Detecting the Rotation of a Quantum Spin

Philip Ball

Physics•Jan 17, 2020•0 citations
We report on the characteristics of a microwave photon-counter device based on a superconducting transmon qubit. Its design is similar to that described by Balembois [], which achieved a sensitivity of 10 − 22 W / Hz , but with an additional bandwidth-tuning circuit that permits tuning the detection bandwidth over an order of magnitude to optimize the efficiency and noise level of the device. As a result of this feature and improvements in device fabrication, a power sensitivity of 3 × 10 − 23 W / Hz is reached. We confirm the high performance of the device by measuring single-spin microwave fluorescence.
Counting the microwave photons emitted by an ensemble of electron spins when they relax radiatively has recently been proposed as a sensitive method for electron paramagnetic resonance spectroscopy, enabled by the development of operational single microwave photon detectors at millikelvin temperature. Here, we report the detection of spin echoes in the spin fluorescence signal. The echo manifests itself as a coherent modulation of the number of photons spontaneously emitted after a $\ensuremath{\pi}/{2}_{X}\ensuremath{-}\ensuremath{\tau}\ensuremath{-}{\ensuremath{\pi}}_{Y}\ensuremath{-}\ensuremath{\tau}\ensuremath{-}\ensuremath{\pi}/{2}_{\mathrm{\ensuremath{\Phi}}}$ sequence, dependent on the relative phase $\mathrm{\ensuremath{\Phi}}$. We demonstrate experimentally this detection method using an ensemble of Er3+{\mathrm{Er}}^{3+}Er3+ ion spins in a scheelite crystal of CaWO4{\mathrm{CaWO}}_{4}CaWO4​. We use fluorescence-detected echoes to measure the erbium spin coherence time, as well as the echo envelope modulation due to the coupling to the 183W^{183}\mathrm{W}183W nuclear spins surrounding each ion. We finally compare the signal-to-noise ratio of inductively detected and fluorescence-detected echoes, and show that it is larger with the fluorescence method.