arXiv:2102.00965 · Physical Review A

Measurement of electric-field noise from interchangeable samples with a trapped-ion sensor

Kyle S. McKay, Dustin A. Hite, Philip D. Kent, Shlomi Kotler, Dietrich G. Leibfried, D. H. Slichter, A. C. Wilson, David P. Pappas

Published Nov 18, 2021• 12 citations
arXivHTMLPDF

Abstract

We demonstrate the use of a single trapped ion as a sensor to probe electric-field noise from interchangeable test surfaces. As proof of principle, we measure the magnitude and distance dependence of electric-field noise from two ion-trap-like samples with patterned Au electrodes. This trapped-ion sensor could be combined with other surface characterization tools to help elucidate the mechanisms that give rise to electric-field noise from ion-trap surfaces. Such noise presents a significant hurdle for performing large-scale trapped-ion quantum computations.

DOI
10.1103/physreva.104.052610

Related papers

Evidence for multiple mechanisms underlying surface electric-field noise in ion traps

Jonathon A. Sedlacek, Jules Stuart, D. H. Slichter +4 more

Electric-field noise from ion-trap electrode surfaces can limit the fidelity of multiqubit entangling operations in trapped-ion quantum information processors and can give rise to systematic errors in trapped-ion optical clocks. The underlying mechanism for this noise is unknown, but it has been shown that the noise amplitude can be reduced by energetic ion bombardment, or ``ion milling,'' of the trap electrode surfaces. Using a single trapped $^{88}\mathrm{Sr}^{+}$ ion as a sensor, we investigate the temperature dependence of this noise both before and after ex situ ion milling of the trap electrodes. Making measurements over a trap electrode temperature range of 4 K to 295 K in both sputtered niobium and electroplated gold traps, we see a marked change in the temperature scaling of the electric-field noise after ion milling: power-law behavior in untreated surfaces is transformed to Arrhenius behavior after treatment. The temperature scaling becomes material-dependent after treatment as well, strongly suggesting that different noise mechanisms are at work before and after ion milling. To constrain potential noise mechanisms, we measure the frequency dependence of the electric-field noise, as well as its dependence on ion-electrode distance, for niobium traps at room temperature both before and after ion milling. These scalings are unchanged by ion milling.

arXiv:1809.07761•Physical Review A•Dec 27, 2018•43 citations

Distance scaling and polarization of electric-field noise in a surface ion trap

Da An, Clemens Matthiesen, Erik Urban +1 more

We probe electric-field noise in a surface ion trap for ion-surface distances $d$ between 50 and 300 \textmu{}m in the normal and planar directions. We find the noise distance dependence to scale as ${d}^{\ensuremath{-}2.6}$ in our trap and a frequency dependence which is consistent with $1/f$ noise. Simulations of the electric-field noise specific to our trap geometry provide evidence that we are not limited by technical noise sources. Our distance scaling data is consistent with a noise correlation length of about 100 \textmu{}m at the trap surface, and we discuss how patch potentials of this size would be modified by the electrode geometry.

arXiv:1906.06489•Physical Review A•Dec 3, 2019•18 citations

Noise sensing and quantum simulation with trapped atomic ions

Dylan J Gorman

In this work, we present a novel method to couple any two vibrational modes of a single trapped ion, allowing energy to be swapped between the two modes. We use the scheme to perform ground state cooling and heating rate measurements of vibrational modes without direct optical access. This lessens experimental design constraints in trapped ion experi- ments, particularly in surface trap apparatus where optical access can be difficult.We use a single ion as an electric-field noise sensor to study noise processes originating on the metallic surfaces of microfabricated ion traps. We show that realistic models of surface noise predict a specific polarization of the electric-field fluctuations relative to the trap geometry. In contrast, technical noise sources predict a different polarization direction and magnitude which can be inferred by electrostatic simulation of the trapping electrodes. We show that, by comparing heating rates of the two radial modes of a single trapped ion, one can determine whether technical noise sources are a significant contribution to heating. This is an important test for experiments aimed at studying surface noise effects. We also study dephasing due to surface noise, in which the electric potential curvature due to surface noise sources disturbs the phase of the ion motion. We measure the dephasing time for trapped ion motion. Using a noise model featuring dipolar noise sources, we probe the power spectrum of surface noise effects. These measurements, especially if repeated in a trap with smaller ion-electrode distances, may yield new insights as to the physical origin of surface noise effects.We demonstrate a two-ion quantum simulation of vibrationally-assisted energy transfer, an important phenomenon in biochemical energy transfer. We show that the quantum simulator performs well when benchmarked against exact numerical simulation. We believe that our approach can be scaled to more complicated systems beyond the reach of classical simulation, and discuss several methods for extending the simulation.

•Jan 1, 2017•0 citations

Surface noise analysis using a single-ion sensor

Nikos Daniilidis, S. Gerber, G. Bolloten +5 more

We use a single-ion electric-field noise sensor in combination with in situ surface treatment and analysis tools, to investigate the relationship between electric-field noise from metal surfaces in vacuum and the composition of the surface. These experiments are performed in a setup that integrates ion trapping capabilities with surface analysis tools. We find that treatment of an aluminum-copper surface with energetic argon ions significantly reduces the level of room-temperature electric-field noise, but the surface does not need to be atomically clean to show noise levels comparable to those of the best cryogenic traps. The noise levels after treatment are low enough to allow fault-tolerant trapped-ion quantum information processing on a microfabricated surface trap at room temperature.

arXiv:1307.7194•Physical Review B•Jun 20, 2014•74 citations

Probing Electric Field Noise Above Ion Traps from 7–600 K and the Influence of Surface Structure on Noise Levels

Benjamin Saarel

Electric field noise produced by the surface of ion trap electrodes reduces the fidelity of quantum computing operations. Despite decades of investigation its microscopic origins remain unclear.This thesis investigates the origins of surface electric field noise by examining its dependence on trap temperature. A set of Al-Cu surface Paul traps are fabricated together and sent to MIT Lincoln Labs (MITLL) and the University of California, Berkeley (UCB). MITLL measures noise from 7 K to room temperature above a first trap and UCB measures noise from room temperature to 590 K above a second trap. The noise measurements from the two experiments are combined to study the noise dependence over the full temperature range from 7-590 K. This is the largest temperature range ever studied using a single trap design and connects the temperature ranges used in all previous studies.We find qualitatively different behaviors at low and high temperatures: from 7-430 K we find that the noise follows the same power-law scaling reported in previous cryogenic studies. At temperatures from 430-590 K, we find that the noise increases much more rapidly than predicted by the power-law scaling. We note a particularly sharp rise in noise at 560 K, which is similar to the sharp rise in noise reported in a previous high-temperature study of a different Al-Cu trap. To determine which physical processes are associated with the change in noise at elevated trap temperatures, we investigate how the material state of the trap electrodes changes when they are heated. We find that the primary physical process associated with the change in noise at high temperature is thermally-activated atom diffusion within the films.This thesis also investigates if the surface structure of room-temperature Au ion traps affects noise levels. We use a heat treatment to restructure the surface of the traps and measure the resulting change in noise. We find that the heat treatment leads to significant changes to the surface structure but causes only a modest change to noise levels. This indicates that the heat-induced changes to the surface do not strongly affect noise. We also note that the noise magnitude observed above these Au traps is state-of-the-art for room-temperature, untreated surface ion traps. This noise level can be explained by modeling the contamination that exists on the trap surface as a dielectric with a loss tangent of tan θ ≈ 0.01.Finally, this thesis investigates the origin of elevated noise levels in one region of a Au surface ion trap. We find that micron-sized particles are located where noise levels are highest, indicating that these particles are likely responsible for the noise. We can explain the magnitude, frequency, and distance dependence of the noise if we treat the particles as a lossy dielectric with a loss tangent tan θ ≈ 0.3.

•May 1, 2026•0 citations

Electrical Noise Produced by Micron-Sized Particles above a Surface Paul Trap

Ben Saarel, Ozgur Sahin, Hartmut Häffner +1 more

Electric field noise produced by the surface of ion trap electrodes reduces the fidelity of quantum computing operations. Despite decades of investigation its microscopic origins remain unclear. Here, we measure electric field noise at trapping locations along the symmetry axis of a linear surface Paul trap. We find that noise levels vary by three orders-of-magnitude in one 600$\,μ$m section of the trap. Optical and scanning electron microscope images show micron-sized particles close to the trapping locations with the highest noise levels. We find that modeling the particles as a lossy dielectric with a effective loss tangent $\tanθ=0.33(0.06)$ describes the magnitude of the noise, as well as its spatial and frequency dependence. Our observations may explain the large variation of reported noise levels in literature.

quant-pharXiv:2606.19585•Journal of Applied Physics•Jun 19, 2026•1 citation
We demonstrate the use of a single trapped ion as a sensor to probe electric-field noise from interchangeable test surfaces. As proof of principle, we measure the magnitude and distance dependence of electric-field noise from two ion-trap-like samples with patterned Au electrodes. This trapped-ion sensor could be combined with other surface characterization tools to help elucidate the mechanisms that give rise to electric-field noise from ion-trap surfaces. Such noise presents a significant hurdle for performing large-scale trapped-ion quantum computations.
Electric-field noise from ion-trap electrode surfaces can limit the fidelity of multiqubit entangling operations in trapped-ion quantum information processors and can give rise to systematic errors in trapped-ion optical clocks. The underlying mechanism for this noise is unknown, but it has been shown that the noise amplitude can be reduced by energetic ion bombardment, or ``ion milling,'' of the trap electrode surfaces. Using a single trapped 88Sr+^{88}\mathrm{Sr}^{+}88Sr+ ion as a sensor, we investigate the temperature dependence of this noise both before and after ex situ ion milling of the trap electrodes. Making measurements over a trap electrode temperature range of 4 K to 295 K in both sputtered niobium and electroplated gold traps, we see a marked change in the temperature scaling of the electric-field noise after ion milling: power-law behavior in untreated surfaces is transformed to Arrhenius behavior after treatment. The temperature scaling becomes material-dependent after treatment as well, strongly suggesting that different noise mechanisms are at work before and after ion milling. To constrain potential noise mechanisms, we measure the frequency dependence of the electric-field noise, as well as its dependence on ion-electrode distance, for niobium traps at room temperature both before and after ion milling. These scalings are unchanged by ion milling.
We probe electric-field noise in a surface ion trap for ion-surface distances ddd between 50 and 300 \textmu{}m in the normal and planar directions. We find the noise distance dependence to scale as ${d}^{\ensuremath{-}2.6}$ in our trap and a frequency dependence which is consistent with 1/f1/f1/f noise. Simulations of the electric-field noise specific to our trap geometry provide evidence that we are not limited by technical noise sources. Our distance scaling data is consistent with a noise correlation length of about 100 \textmu{}m at the trap surface, and we discuss how patch potentials of this size would be modified by the electrode geometry.
In this work, we present a novel method to couple any two vibrational modes of a single trapped ion, allowing energy to be swapped between the two modes. We use the scheme to perform ground state cooling and heating rate measurements of vibrational modes without direct optical access. This lessens experimental design constraints in trapped ion experi- ments, particularly in surface trap apparatus where optical access can be difficult.We use a single ion as an electric-field noise sensor to study noise processes originating on the metallic surfaces of microfabricated ion traps. We show that realistic models of surface noise predict a specific polarization of the electric-field fluctuations relative to the trap geometry. In contrast, technical noise sources predict a different polarization direction and magnitude which can be inferred by electrostatic simulation of the trapping electrodes. We show that, by comparing heating rates of the two radial modes of a single trapped ion, one can determine whether technical noise sources are a significant contribution to heating. This is an important test for experiments aimed at studying surface noise effects. We also study dephasing due to surface noise, in which the electric potential curvature due to surface noise sources disturbs the phase of the ion motion. We measure the dephasing time for trapped ion motion. Using a noise model featuring dipolar noise sources, we probe the power spectrum of surface noise effects. These measurements, especially if repeated in a trap with smaller ion-electrode distances, may yield new insights as to the physical origin of surface noise effects.We demonstrate a two-ion quantum simulation of vibrationally-assisted energy transfer, an important phenomenon in biochemical energy transfer. We show that the quantum simulator performs well when benchmarked against exact numerical simulation. We believe that our approach can be scaled to more complicated systems beyond the reach of classical simulation, and discuss several methods for extending the simulation.
We use a single-ion electric-field noise sensor in combination with in situ surface treatment and analysis tools, to investigate the relationship between electric-field noise from metal surfaces in vacuum and the composition of the surface. These experiments are performed in a setup that integrates ion trapping capabilities with surface analysis tools. We find that treatment of an aluminum-copper surface with energetic argon ions significantly reduces the level of room-temperature electric-field noise, but the surface does not need to be atomically clean to show noise levels comparable to those of the best cryogenic traps. The noise levels after treatment are low enough to allow fault-tolerant trapped-ion quantum information processing on a microfabricated surface trap at room temperature.
Electric field noise produced by the surface of ion trap electrodes reduces the fidelity of quantum computing operations. Despite decades of investigation its microscopic origins remain unclear.This thesis investigates the origins of surface electric field noise by examining its dependence on trap temperature. A set of Al-Cu surface Paul traps are fabricated together and sent to MIT Lincoln Labs (MITLL) and the University of California, Berkeley (UCB). MITLL measures noise from 7 K to room temperature above a first trap and UCB measures noise from room temperature to 590 K above a second trap. The noise measurements from the two experiments are combined to study the noise dependence over the full temperature range from 7-590 K. This is the largest temperature range ever studied using a single trap design and connects the temperature ranges used in all previous studies.We find qualitatively different behaviors at low and high temperatures: from 7-430 K we find that the noise follows the same power-law scaling reported in previous cryogenic studies. At temperatures from 430-590 K, we find that the noise increases much more rapidly than predicted by the power-law scaling. We note a particularly sharp rise in noise at 560 K, which is similar to the sharp rise in noise reported in a previous high-temperature study of a different Al-Cu trap. To determine which physical processes are associated with the change in noise at elevated trap temperatures, we investigate how the material state of the trap electrodes changes when they are heated. We find that the primary physical process associated with the change in noise at high temperature is thermally-activated atom diffusion within the films.This thesis also investigates if the surface structure of room-temperature Au ion traps affects noise levels. We use a heat treatment to restructure the surface of the traps and measure the resulting change in noise. We find that the heat treatment leads to significant changes to the surface structure but causes only a modest change to noise levels. This indicates that the heat-induced changes to the surface do not strongly affect noise. We also note that the noise magnitude observed above these Au traps is state-of-the-art for room-temperature, untreated surface ion traps. This noise level can be explained by modeling the contamination that exists on the trap surface as a dielectric with a loss tangent of tan θ ≈ 0.01.Finally, this thesis investigates the origin of elevated noise levels in one region of a Au surface ion trap. We find that micron-sized particles are located where noise levels are highest, indicating that these particles are likely responsible for the noise. We can explain the magnitude, frequency, and distance dependence of the noise if we treat the particles as a lossy dielectric with a loss tangent tan θ ≈ 0.3.
Electric field noise produced by the surface of ion trap electrodes reduces the fidelity of quantum computing operations. Despite decades of investigation its microscopic origins remain unclear. Here, we measure electric field noise at trapping locations along the symmetry axis of a linear surface Paul trap. We find that noise levels vary by three orders-of-magnitude in one 600 μ\,μμm section of the trap. Optical and scanning electron microscope images show micron-sized particles close to the trapping locations with the highest noise levels. We find that modeling the particles as a lossy dielectric with a effective loss tangent tan⁡θ=0.33(0.06)\tanθ=0.33(0.06)tanθ=0.33(0.06) describes the magnitude of the noise, as well as its spatial and frequency dependence. Our observations may explain the large variation of reported noise levels in literature.