Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2011.10081 · Physical Review A

Single-atom counting in a two-color magneto-optical trap

Martin Schlederer, Alexandra Mozdzen, Thomas Lompe, Henning Moritz

Published Mar 12, 2021• 3 citations
arXivHTMLPDF

Abstract

Recording the fluorescence of a magneto-optical trap (MOT) is a standard tool for measuring atom numbers in experiments with ultracold atoms. When trapping few atoms in a small MOT, the emitted fluorescence increases with the atom number in discrete steps, which allows one to measure the atom number with single-particle resolution. Achieving such single-particle resolution requires stringent minimization of stray light from the MOT beams, which is very difficult to achieve in experimental setups that require in-vacuum components close to the atoms. Here, we present a modified scheme that addresses this issue: Instead of collecting the fluorescence on the MOT (D2) transition, we scatter light on an additional probing (D1) transition and collect this fluorescence with a high-resolution microscope while filtering out the intense MOT light. Using this scheme, we are able to reliably distinguish up to 17 $^{40}\mathrm{K}$ atoms with classification fidelities of $\ensuremath{\sim}98%$ for up to 5 atom numbers and fidelities of more than 85% for up to 17 atoms.

DOI
10.1103/physreva.103.033308

Related papers

Background-free fluorescence detection of cold atoms in a two-color magneto-optical trap

Baodong Yang, Qiangbing Liang, Jun He +1 more

A two-color magneto-optical trap (MOT) for trapping cesium (Cs) atoms is experimentally realized. This two-color MOT employs the radiation forces due to photon scattering from the Cs 6P(3/2) F' = 5 - 8S(1/2) F" = 4 excited-state transition, which replaced one pair of the three pairs of cooling/trapping laser beams operating on a single-photon red detuning to the Cs 6S(1/2) F = 4 - 6P(3/2) F' = 5 cycling transition in a standard six-beam Cs MOT, and can cool and trap atoms on both the red-detuning and blue-detuning sides of the two-photon resonance. Employing the two-color MOT, the background-free fluorescence detection of trapped atoms has been demonstrated. This technique will be useful for observation of weak fluorescence signal radiated from single atoms in MOT.

Optics Express•May 10, 2012•9 citations

Detection of a single lithium atom in a magneto-optical trap

Hyok Sang Han, Seokchan Yoon, D. Cho

We report fluorescence detection of a single 7 Li atom in a magneto-optical trap (MOT). We use a double MOT system, which allows us to control the loading rate of the second MOT by simply turning on or off the first MOT and to use a modest magnetic field gradient of 46 G/cm. A single atom is trapped for longer than 100 s. The fluorescence from the trapped atoms is imaged onto an electron-multiplying charge-coupled device with a unit magnification factor by a pair of aspheric lenses. The numerical aperture of the objective lens is 0.22 with a collecting efficiency of 1.3%. Accumulated fluorescence is extracted by integrating the signal over a region of interest of 500×350 μ m 2 . For a 200-ms exposure time, the fluorescence count from a single atom is 8.8×10 3 and the background count from scattered MOT beams is 6.8 × 10 4 . We actively stabilize the trap beam power to reduce the noise and the measured noise is two times the statistical noise. Overall signal-to-noise ratio of the single-atom detection is 37/√ Hz. We also describe a modification of the system that is adapted to an experimental configuration for quantum manipulation of single atoms in a 1D optical lattice.

Journal of the Korean Physical Society•Jun 1, 2015•4 citations

Improved atom number with a dual color magneto—optical trap

Qiang Cao, Xinyu Luo, Kui-Yi Gao +3 more

We demonstrate a novel dual color magneto—optical trap (MOT), which uses two sets of overlapping laser beams to cool and trap 87 Rb atoms. The volume of cold cloud in the dual color MOT is strongly dependent on the frequency difference of the laser beams and can be significantly larger than that in the normal MOT with single frequency MOT beams. Our experiment shows that the dual color MOT has the same loading rate as the normal MOT, but much longer loading time, leading to threefold increase in the number of trapped atoms. This indicates that the larger number is caused by reduced light induced loss. The dual color MOT is very useful in experiments where both high vacuum level and large atom number are required, such as single chamber quantum memory and Bose—Einstein condensation (BEC) experiments. Compared to the popular dark spontaneous-force optical trap (dark SPOT) technique, our approach is technically simpler and more suitable to low power laser systems.

Chinese Physics B•Apr 1, 2012•9 citations

Optimization of a magneto–optic trap using nanofibers*

Xin Wang, Li-Jun Song, Chenxi Wang +3 more

We experimentally demonstrate a reliable method based on a nanofiber to optimize the number of cold atoms in a magneto–optical trap (MOT) and to monitor the MOT in real time. The atomic fluorescence is collected by a nanofiber with subwavelength diameter of about 400 nm. The MOT parameters are experimentally adjusted in order to match the maximum number of cold atoms provided by the fluorescence collected by the nanofiber. The maximum number of cold atoms is obtained when the intensities of the cooling and re-pumping beams are about 23.5 mW/cm2 and 7.1 mW/cm2, respectively; the detuning of the cooling beam is −13.0 MHz, and the axial magnetic gradient is about 9.7 Gauss/cm. We observe a maximum photon counting rate of nearly (4.5±0.1) × 105 counts/s. The nanofiber–atom system can provide a powerful and flexible tool for sensitive atom detection and for monitoring atom–matter coupling. It can be widely used from quantum optics to quantum precision measurement.

Chinese Physics B•Jul 1, 2019•7 citations

Photon-scattering-rate measurement of atoms in a magneto-optical trap

Kais Jooya, Nam Musterer, Kirk W. Madison +1 more

We present a technique for empirically determining the photon scattering rate of atoms in a magneto-optical trap (MOT). An accurate measurement of the scattering rate provides a way to accurately determine the number of atoms in the MOT, the excited-state fraction, and the in situ light intensity experienced by the atoms in the trap. We validate this technique for determining the scattering rate by comparing the atom number determined by the fluorescence emitted by atoms in a MOT with an independent and unrelated measure of the number determined by an absorption measurement of an optical pumping beam. We also observe minor deviations from the two-level model for the single-photon scattering rate and extend our analysis to a four-level model. The main advantage of the method described here is that it provides a simple way of determining the photon scattering rate of the MOT empirically and, thus, of evaluating the atom number from fluorescence measurements more accurately.

Physical Review A•Dec 2, 2013•9 citations

Two-color ytterbium magneto-optical trap in a compact dual-chamber setup

Xin Wang, Thilina Muthu-Arachchige, Tangi Legrand +4 more

We present an experimental scheme for producing ultracold ytterbium atoms in a compact dual-chamber setup. A dispenser-loaded two-dimensional magneto-optical trap (MOT) using permanent magnets and operating on the broad ${}^{1}{S}_{0}\ensuremath{\rightarrow}{}^{1}{P}_{1}$ singlet transition delivers over ${10}^{7}$ atoms per second through a differential pumping stage into a three-dimensional MOT. The two-color three-dimensional MOT uses the broad singlet transition to accumulate $\ensuremath{\sim}2\ifmmode\times\else\texttimes\fi{}{10}^{7}$ atoms of ${}^{174}\mathrm{Yb}$ within 2.5 s and subsequently the narrow ${}^{1}{S}_{0}\ensuremath{\rightarrow}{}^{3}{P}_{1}$ intercombination line to cool the atomic cloud to below 10 \textmu{}K. We report optimized parameters for each stage of the atom collection sequence, achieving high transfer efficiency. We find that shelving into the triplet state during the broad-transition MOT almost doubles the number of trapped atoms.

arXiv:2408.03310•Physical Review Applied•Jan 3, 2025•5 citations
Recording the fluorescence of a magneto-optical trap (MOT) is a standard tool for measuring atom numbers in experiments with ultracold atoms. When trapping few atoms in a small MOT, the emitted fluorescence increases with the atom number in discrete steps, which allows one to measure the atom number with single-particle resolution. Achieving such single-particle resolution requires stringent minimization of stray light from the MOT beams, which is very difficult to achieve in experimental setups that require in-vacuum components close to the atoms. Here, we present a modified scheme that addresses this issue: Instead of collecting the fluorescence on the MOT (D2) transition, we scatter light on an additional probing (D1) transition and collect this fluorescence with a high-resolution microscope while filtering out the intense MOT light. Using this scheme, we are able to reliably distinguish up to 17 40K^{40}\mathrm{K}40K atoms with classification fidelities of \ensuremath∼98\ensuremath{\sim}98%\ensuremath∼98 for up to 5 atom numbers and fidelities of more than 85% for up to 17 atoms.
A two-color magneto-optical trap (MOT) for trapping cesium (Cs) atoms is experimentally realized. This two-color MOT employs the radiation forces due to photon scattering from the Cs 6P(3/2) F' = 5 - 8S(1/2) F" = 4 excited-state transition, which replaced one pair of the three pairs of cooling/trapping laser beams operating on a single-photon red detuning to the Cs 6S(1/2) F = 4 - 6P(3/2) F' = 5 cycling transition in a standard six-beam Cs MOT, and can cool and trap atoms on both the red-detuning and blue-detuning sides of the two-photon resonance. Employing the two-color MOT, the background-free fluorescence detection of trapped atoms has been demonstrated. This technique will be useful for observation of weak fluorescence signal radiated from single atoms in MOT.
We report fluorescence detection of a single 7 Li atom in a magneto-optical trap (MOT). We use a double MOT system, which allows us to control the loading rate of the second MOT by simply turning on or off the first MOT and to use a modest magnetic field gradient of 46 G/cm. A single atom is trapped for longer than 100 s. The fluorescence from the trapped atoms is imaged onto an electron-multiplying charge-coupled device with a unit magnification factor by a pair of aspheric lenses. The numerical aperture of the objective lens is 0.22 with a collecting efficiency of 1.3%. Accumulated fluorescence is extracted by integrating the signal over a region of interest of 500×350 μ m 2 . For a 200-ms exposure time, the fluorescence count from a single atom is 8.8×10 3 and the background count from scattered MOT beams is 6.8 × 10 4 . We actively stabilize the trap beam power to reduce the noise and the measured noise is two times the statistical noise. Overall signal-to-noise ratio of the single-atom detection is 37/√ Hz. We also describe a modification of the system that is adapted to an experimental configuration for quantum manipulation of single atoms in a 1D optical lattice.
We demonstrate a novel dual color magneto—optical trap (MOT), which uses two sets of overlapping laser beams to cool and trap 87 Rb atoms. The volume of cold cloud in the dual color MOT is strongly dependent on the frequency difference of the laser beams and can be significantly larger than that in the normal MOT with single frequency MOT beams. Our experiment shows that the dual color MOT has the same loading rate as the normal MOT, but much longer loading time, leading to threefold increase in the number of trapped atoms. This indicates that the larger number is caused by reduced light induced loss. The dual color MOT is very useful in experiments where both high vacuum level and large atom number are required, such as single chamber quantum memory and Bose—Einstein condensation (BEC) experiments. Compared to the popular dark spontaneous-force optical trap (dark SPOT) technique, our approach is technically simpler and more suitable to low power laser systems.
We experimentally demonstrate a reliable method based on a nanofiber to optimize the number of cold atoms in a magneto–optical trap (MOT) and to monitor the MOT in real time. The atomic fluorescence is collected by a nanofiber with subwavelength diameter of about 400 nm. The MOT parameters are experimentally adjusted in order to match the maximum number of cold atoms provided by the fluorescence collected by the nanofiber. The maximum number of cold atoms is obtained when the intensities of the cooling and re-pumping beams are about 23.5 mW/cm2 and 7.1 mW/cm2, respectively; the detuning of the cooling beam is −13.0 MHz, and the axial magnetic gradient is about 9.7 Gauss/cm. We observe a maximum photon counting rate of nearly (4.5±0.1) × 105 counts/s. The nanofiber–atom system can provide a powerful and flexible tool for sensitive atom detection and for monitoring atom–matter coupling. It can be widely used from quantum optics to quantum precision measurement.
We present a technique for empirically determining the photon scattering rate of atoms in a magneto-optical trap (MOT). An accurate measurement of the scattering rate provides a way to accurately determine the number of atoms in the MOT, the excited-state fraction, and the in situ light intensity experienced by the atoms in the trap. We validate this technique for determining the scattering rate by comparing the atom number determined by the fluorescence emitted by atoms in a MOT with an independent and unrelated measure of the number determined by an absorption measurement of an optical pumping beam. We also observe minor deviations from the two-level model for the single-photon scattering rate and extend our analysis to a four-level model. The main advantage of the method described here is that it provides a simple way of determining the photon scattering rate of the MOT empirically and, thus, of evaluating the atom number from fluorescence measurements more accurately.
We present an experimental scheme for producing ultracold ytterbium atoms in a compact dual-chamber setup. A dispenser-loaded two-dimensional magneto-optical trap (MOT) using permanent magnets and operating on the broad ${}^{1}{S}_{0}\ensuremath{\rightarrow}{}^{1}{P}_{1}$ singlet transition delivers over 107{10}^{7}107 atoms per second through a differential pumping stage into a three-dimensional MOT. The two-color three-dimensional MOT uses the broad singlet transition to accumulate $\ensuremath{\sim}2\ifmmode\times\else\texttimes\fi{}{10}^{7}$ atoms of 174Yb{}^{174}\mathrm{Yb}174Yb within 2.5 s and subsequently the narrow ${}^{1}{S}_{0}\ensuremath{\rightarrow}{}^{3}{P}_{1}$ intercombination line to cool the atomic cloud to below 10 \textmu{}K. We report optimized parameters for each stage of the atom collection sequence, achieving high transfer efficiency. We find that shelving into the triplet state during the broad-transition MOT almost doubles the number of trapped atoms.