arXiv:2011.08955 · Physical Review A

Field-gradient measurement using a Stern-Gerlach atomic interferometer with butterfly geometry

Changhun Oh, Hyukjoon Kwon, Liang Jiang, M. S. Kim

Published Nov 24, 2020• 3 citations
arXivHTMLPDF

Abstract

Atomic interferometers have been studied as a promising device for precise sensing of external fields. Among various configurations, a particular configuration with a butterfly-shaped geometry has been designed to sensitively probe field gradients. We introduce a Stern-Gerlach (SG) butterfly interferometer by incorporating magnetic field in the conventional butterfly-shaped configuration. Atomic trajectories of the interferometer can be flexibly adjusted by controlling magnetic fields to increase the sensitivity of the interferometer, while the conventional butterfly interferometer using Raman transitions can be understood as a special case. We also show that the SG interferometer can keep high contrast against a misalignment in position and momentum caused by the field gradient.

DOI
10.1103/physreva.102.053321

Related papers

Realization of a complete Stern-Gerlach interferometer

Yair Margalit, Zhifan Zhou, Or Dobkowski +4 more

The Stern-Gerlach (SG) effect, discovered almost a century ago, has become a paradigm of quantum mechanics. Surprisingly there is little evidence that the original scheme with freely propagating atoms exposed to gradients from macroscopic magnets is a fully coherent quantum process. Specifically, no high-visibility spatial interference pattern has been observed with such a scheme, and furthermore no full-loop SG interferometer has been realized with the scheme as envisioned decades ago. On the contrary, numerous theoretical studies explained why it is a near impossible endeavor. Here we demonstrate for the first time both a high-visibility spatial SG interference pattern and a full-loop SG interferometer, based on an accurate magnetic field, originating from an atom chip, that ensures coherent operation within strict constraints described by previous theoretical analyses. This also allows us to observe the gradual emergence of time-irreversibility as the splitting is increased. Finally, achieving this high level of control over magnetic gradients may facilitate technological applications such as large-momentum-transfer beam splitting for metrology with atom interferometry, ultra-sensitive probing of electron transport down to shot-noise and squeezed currents, as well as nuclear magnetic resonance and compact accelerators.

arXiv:1801.02708•Jan 8, 2018•35 citations

T 3 Stern-Gerlach Matter-Wave Interferometer

Omer Amit, Yair Margalit, Or Dobkowski +8 more

We present a unique matter-wave interferometer whose phase scales with the cube of the time the atom spends in the interferometer. Our scheme is based on a full-loop Stern-Gerlach interferometer incorporating four magnetic field gradient pulses to create a state-dependent force. In contrast to typical atom interferometers that make use of laser light for the splitting and recombination of the wave packets, this realization uses no light and can therefore serve as a high-precision surface probe at very close distances.

arXiv:1908.03879•Physical Review Letters•Aug 21, 2019•78 citations

Analysis of a high-stability Stern–Gerlach spatial fringe interferometer

Yair Margalit, Zhifan Zhou, Shimon Machluf +3 more

The discovery of the Stern–Gerlach (SG) effect almost a century ago was followed by suggestions to use the effect as a basis for matter-wave interferometry. However, the coherence of splitting particles with spin by a magnetic gradient to a distance exceeding the position uncertainty in each of the arms was not demonstrated until recently, where spatial interference fringes were observed in a proof-of-principle experiment. Here we present and analyze the performance of an improved high-stability SG spatial fringe interferometer based on two spatially separate wave packets with a maximal distance that is more than an order of magnitude larger than their minimal widths. The improved performance is enabled by accurate magnetic field gradient pulses, originating from a novel atom chip configuration, which ensures high stability of the interferometer operation. We analyze the achieved stability using several models, discuss sources of noise, and detail interferometer optimization procedures. We also present a simple analytical phase-space description of the interferometer sequence that demonstrates quantitatively the complete separation of the superposed wave packets 2 .

New Journal of Physics•Jul 8, 2019•26 citations

Stern-Gerlach interferometry in three dimensions: The role of transverse fields

D. Meng, D. Chan, J. D. D. Martin

We show that superficially similar implementations of Stern-Gerlach Interferometers (SGIs) are expected to differ dramatically in their sensitivity to fields transverse to the primary acceleration direction. These transverse fields unavoidably accompany any static magnetic or electric field gradients, and have been shown by Comparat [Phys. Rev. A 101, 023606 (2020)] to limit the precision application of SGIs. As a concrete example, we consider SGIs with ultracold Rb Rydberg atoms accelerated by spatially-varying electric fields. We find that the deleterious effect of transverse fields imply that only some implementations (sequences of field gradients, internal state swaps, and so-on) may exhibit fringes with high visibility.

arXiv:2604.00807•Physical Review A•Mar 9, 2026•0 citations

Stern-Gerlach Interferometry with the Atom Chip

Mark Keil, Shimon Machluf, Yair Margalit +12 more

Abstract In this invited review in honor of 100 years since the Stern-Gerlach (SG) experiments, we describe a decade of SG interferometry on the atom chip. The SG effect has been a paradigm of quantum mechanics throughout the last century, but there has been surprisingly little evidence that the original scheme, with freely propagating atoms exposed to gradients from macroscopic magnets, is a fully coherent quantum process. Specifically, no full-loop SG interferometer (SGI) has been realized with the scheme as envisioned decades ago. Furthermore, several theoretical studies have explained why it is a formidable challenge. Here we provide a review of our SG experiments over the last decade. We describe several novel configurations such as that giving rise to the first SG spatial interference fringes, and the first full-loop SGI realization. These devices are based on highly accurate magnetic fields, originating from an atom chip, that ensure coherent operation within strict constraints described by previous theoretical analyses. Achieving this high level of control over magnetic gradients is expected to facilitate technological applications such as probing of surfaces and currents, as well as metrology. Fundamental applications include the probing of the foundations of quantum theory, gravity, and the interface of quantum mechanics and gravity. We end with an outlook describing possible future experiments.

arXiv:2009.08112•Springer eBooks•Jan 1, 2021•17 citations

Atom-interferometric techniques for measuring uniform magnetic field gradients and gravitational acceleration

B. Barrett, I. Y. Chan, Anantharaman Kumarakrishnan

We discuss techniques for probing the effects of a constant force acting on cold atoms using two configurations of a grating echo-type atom interferometer. Laser-cooled samples of ${}^{85}$Rb with temperatures as low as 2.4 $\ensuremath{\mu}$K have been achieved in a new experimental apparatus with a well-controlled magnetic environment. We demonstrate interferometer signal lifetimes approaching the transit time limit in this system ($\ensuremath{\sim}270$ ms), which is comparable to the time scale achieved by Raman interferometers. Using these long time scales, we experimentally investigate the influence of a homogeneous magnetic field gradient using two- and three-pulse interferometers, which enable us to sense changes in externally applied magnetic field gradients as small as $\ensuremath{\sim}4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}5}$ G/cm. We also provide an improved theoretical description of signals generated by both interferometer configurations that accurately models experimental results. With this theory, absolute measurements of $B$ gradients at the level of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ G/cm are achieved. Finally, we contrast the suitability of the two- and three-pulse interferometers for precision measurements of the gravitational acceleration, $g$.

arXiv:1104.4577•Physical Review A•Dec 19, 2011•29 citations
Atomic interferometers have been studied as a promising device for precise sensing of external fields. Among various configurations, a particular configuration with a butterfly-shaped geometry has been designed to sensitively probe field gradients. We introduce a Stern-Gerlach (SG) butterfly interferometer by incorporating magnetic field in the conventional butterfly-shaped configuration. Atomic trajectories of the interferometer can be flexibly adjusted by controlling magnetic fields to increase the sensitivity of the interferometer, while the conventional butterfly interferometer using Raman transitions can be understood as a special case. We also show that the SG interferometer can keep high contrast against a misalignment in position and momentum caused by the field gradient.
The Stern-Gerlach (SG) effect, discovered almost a century ago, has become a paradigm of quantum mechanics. Surprisingly there is little evidence that the original scheme with freely propagating atoms exposed to gradients from macroscopic magnets is a fully coherent quantum process. Specifically, no high-visibility spatial interference pattern has been observed with such a scheme, and furthermore no full-loop SG interferometer has been realized with the scheme as envisioned decades ago. On the contrary, numerous theoretical studies explained why it is a near impossible endeavor. Here we demonstrate for the first time both a high-visibility spatial SG interference pattern and a full-loop SG interferometer, based on an accurate magnetic field, originating from an atom chip, that ensures coherent operation within strict constraints described by previous theoretical analyses. This also allows us to observe the gradual emergence of time-irreversibility as the splitting is increased. Finally, achieving this high level of control over magnetic gradients may facilitate technological applications such as large-momentum-transfer beam splitting for metrology with atom interferometry, ultra-sensitive probing of electron transport down to shot-noise and squeezed currents, as well as nuclear magnetic resonance and compact accelerators.
We present a unique matter-wave interferometer whose phase scales with the cube of the time the atom spends in the interferometer. Our scheme is based on a full-loop Stern-Gerlach interferometer incorporating four magnetic field gradient pulses to create a state-dependent force. In contrast to typical atom interferometers that make use of laser light for the splitting and recombination of the wave packets, this realization uses no light and can therefore serve as a high-precision surface probe at very close distances.
The discovery of the Stern–Gerlach (SG) effect almost a century ago was followed by suggestions to use the effect as a basis for matter-wave interferometry. However, the coherence of splitting particles with spin by a magnetic gradient to a distance exceeding the position uncertainty in each of the arms was not demonstrated until recently, where spatial interference fringes were observed in a proof-of-principle experiment. Here we present and analyze the performance of an improved high-stability SG spatial fringe interferometer based on two spatially separate wave packets with a maximal distance that is more than an order of magnitude larger than their minimal widths. The improved performance is enabled by accurate magnetic field gradient pulses, originating from a novel atom chip configuration, which ensures high stability of the interferometer operation. We analyze the achieved stability using several models, discuss sources of noise, and detail interferometer optimization procedures. We also present a simple analytical phase-space description of the interferometer sequence that demonstrates quantitatively the complete separation of the superposed wave packets 2 .
We show that superficially similar implementations of Stern-Gerlach Interferometers (SGIs) are expected to differ dramatically in their sensitivity to fields transverse to the primary acceleration direction. These transverse fields unavoidably accompany any static magnetic or electric field gradients, and have been shown by Comparat [Phys. Rev. A 101, 023606 (2020)] to limit the precision application of SGIs. As a concrete example, we consider SGIs with ultracold Rb Rydberg atoms accelerated by spatially-varying electric fields. We find that the deleterious effect of transverse fields imply that only some implementations (sequences of field gradients, internal state swaps, and so-on) may exhibit fringes with high visibility.
Abstract In this invited review in honor of 100 years since the Stern-Gerlach (SG) experiments, we describe a decade of SG interferometry on the atom chip. The SG effect has been a paradigm of quantum mechanics throughout the last century, but there has been surprisingly little evidence that the original scheme, with freely propagating atoms exposed to gradients from macroscopic magnets, is a fully coherent quantum process. Specifically, no full-loop SG interferometer (SGI) has been realized with the scheme as envisioned decades ago. Furthermore, several theoretical studies have explained why it is a formidable challenge. Here we provide a review of our SG experiments over the last decade. We describe several novel configurations such as that giving rise to the first SG spatial interference fringes, and the first full-loop SGI realization. These devices are based on highly accurate magnetic fields, originating from an atom chip, that ensure coherent operation within strict constraints described by previous theoretical analyses. Achieving this high level of control over magnetic gradients is expected to facilitate technological applications such as probing of surfaces and currents, as well as metrology. Fundamental applications include the probing of the foundations of quantum theory, gravity, and the interface of quantum mechanics and gravity. We end with an outlook describing possible future experiments.
We discuss techniques for probing the effects of a constant force acting on cold atoms using two configurations of a grating echo-type atom interferometer. Laser-cooled samples of 85{}^{85}85Rb with temperatures as low as 2.4 $\ensuremath{\mu}$K have been achieved in a new experimental apparatus with a well-controlled magnetic environment. We demonstrate interferometer signal lifetimes approaching the transit time limit in this system ($\ensuremath{\sim}270$ ms), which is comparable to the time scale achieved by Raman interferometers. Using these long time scales, we experimentally investigate the influence of a homogeneous magnetic field gradient using two- and three-pulse interferometers, which enable us to sense changes in externally applied magnetic field gradients as small as $\ensuremath{\sim}4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}5}$ G/cm. We also provide an improved theoretical description of signals generated by both interferometer configurations that accurately models experimental results. With this theory, absolute measurements of BBB gradients at the level of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ G/cm are achieved. Finally, we contrast the suitability of the two- and three-pulse interferometers for precision measurements of the gravitational acceleration, ggg.