Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2009.06590 · Physical Review A

Gaussian phase sensitivity of boson-sampling-inspired strategies

Antonio A. Valido, Juan José García‐Ripoll

Published Mar 24, 2021• 2 citations
arXivHTMLPDF

Abstract

In this paper we study the phase sensitivity of generic linear interferometric schemes using Gaussian resources and measurements. Our formalism is based on the Fisher information. This allows us to separate the contributions of the measurement scheme, the experimental imperfections, and auxiliary systems. We demonstrate the strength of this formalism using a broad class of multimode Gaussian states that includes well-known results from single- and two-mode metrology scenarios. Using this, we prove that input coherent states or squeezing improve upon the nonclassical states proposed in preceding boson-sampling-inspired phase-estimation schemes. We also develop a polychromatic interferometric protocol, demonstrating an enhanced sensitivity with respect to two-mode squeezed-vacuum states, for which the ideal homodyne detection is formally shown to be optimal.

DOI
10.1103/physreva.103.032613

Related papers

Phase Estimation in Linear and Nonlinear Interferometers

Sushovit Adhikari

Phase estimation has a wide range of applications. Over the years, several strategies have been studied to improve precision in phase estimation. These strategies include using exotic quantum states to quantum detection schemes. This dissertation summarizes my effort in improving the precision of phase estimation with a linear and nonlinear interferometer. Chapter 1 introduces quantum optics and quantum metrology. I introduce all relevant quantum states of light used. We also look into tools and terminologies of quantum metrology such as Fisher information, shot-noise limit, Heisenberg limit, etc., along with examples of phase estimation with a Mach-Zehnder interferometer. In Chapter 2, I discuss multiple phase estimation using a multimode interferometer. Building upon previous work, our scheme consists of a multimode interferometer with single-photon inputs. By using a quantum Fisher information analysis, we show that our scheme gives a constant improvement over other schemes. We also show that our scheme with photon-number-resolving detection approaches the quantum Cram\'er-Rao bound. Moreover, we also consider the probabilistic nature of photon emission at the input, and we study its effect on phase sensitivity. I discuss phase estimation with SU(1,1) interferometer in Chapter 3. We look at phase sensitivity in this interferometer with different input states. Namely, we consider two different phase estimation scheme, one using thermal and squeezed states, and others using coherent and displaced squeezed states with parity and on-off as a detection scheme. We also look into the effect of photon loss inside the interferometer. In Chapter 4, we revisit phase estimation in SU(1,1) interferometer from the perspective of quantum Fisher information. I discuss in detail a longstanding confusion regarding the use of quantum Fisher information in SU(1,1) interferometer. We show that phase averaging or quantum Fisher information matrix method is needed in general for calculating the phase sensitivity which resolves inconsistencies reported in previously published articles.

Civil War Book Review•Feb 22, 2019•0 citations

Squeezing as a resource to counteract phase diffusion in optical phase estimation

Giacomo Carrara, Marco G. Genoni, S. Cialdi +2 more

We address a phase estimation scheme using Gaussian states in the presence of non-Gaussian phase noise. At variance with previous analysis, we analyze situations in which the noise occurs before encoding phase information. In particular, we study how squeezing may be profitably used before or after phase diffusion. Our results show that squeezing the probe after the noise greatly enhances the sensitivity of the estimation scheme, as witnessed by the increase of the quantum Fisher information. We then consider a realistic setup in which homodyne detection is employed at the measurement stage, and we address its optimality as well as its performance in the two different scenarios.

arXiv:2008.03161•Physical Review A•Dec 16, 2020•11 citations

Quantum metrology via multipartite non-Gaussian states

Irving R. Isaac, Hyunchul Nha

We study quantum phase estimation using multimode non-Gaussian states to investigate quantum enhancement of measurement precision due to the characteristics of multipartite quantum entanglement. We consider two prototypical classes of multipartite entangled states, namely, GHZ-type and W-type entangled states of N optical modes and obtain an optimal configuration for each case by dividing N modes into two parts, one sent to phase-region and the other to empty region. In the lossless regime, both classes exhibit the Heisenberg scaling of quantum Fisher information (QFI) with input energy while the metrological advantage using larger-mode multipartite entanglement appears only in W-type states. We extend our analysis to include photon loss under practical measurement schemes, i.e. Fourier-assisted photon-counting and homodyne detection, and show to what extent the Fisher information under each measurement scheme can approach the ultimate QFI beyond the standard quantum limit.

Scientific Reports•Nov 13, 2026•0 citations

Optimal Gaussian metrology for generic multimode interferometric circuit

Teruo Matsubara, Paolo Facchi A, Vittorio Giovannetti +1 more

Bounds on the ultimate precision attainable in the estimation of a parameter in Gaussian quantum metrology are obtained when the average number of bosonic probes is fixed.We identify the optimal input probe state among generic (mixed in general) Gaussian states with a fixed average number of probe photons for the estimation of a parameter contained in a generic multimode interferometric optical circuit, namely, a passive linear circuit preserving the total number of photons.The optimal Gaussian input state is essentially a single-mode squeezed vacuum, and the ultimate precision is achieved by a homodyne measurement on the single mode.We also reveal the best strategy for the estimation when we are given L identical target circuits and are allowed to apply passive linear controls in between with an arbitrary number of ancilla modes introduced.

arXiv:1802.01452•New Journal of Physics•Feb 11, 2019•33 citations

Practical resources and measurements for lossy optical quantum metrology

Changhun Oh, Su-Yong Lee, Hyunchul Nha +1 more

We study the sensitivity of phase estimation in a lossy Mach-Zehnder interferometer (MZI) using two general, and practical, resources generated by a laser and a nonlinear optical medium with passive optimal elements, which are readily available in the laboratory: One is a two-mode separable coherent and squeezed vacuum state at a beam splitter and the other is a two-mode squeezed vacuum state. In view of the ultimate precision given by quantum Fisher information, we show that the two-mode squeezed vacuum state can achieve a lower bound of estimation error than the coherent and squeezed vacuum state under a photon-loss channel. We further consider practical measurement schemes, homodyne detection and photon number resolving detection (PNRD), to characterize the accuracy of phase estimation in reality and find that the coherent and squeezed vacuum state largely achieves a lower bound than the two-mode squeezed vacuum in the lossy MZI while maintaining quantum enhancement over the shot-noise limit. By comparing homodyne detection and PNRD, we demonstrate that quadrature measurement with homodyne detection is more robust against photon loss than parity measurement with PNRD. We also show that double homodyne detection can provide a better tool for phase estimation than single homodyne detection against photon loss.

arXiv:1707.03210•Physical Review A•Dec 4, 2017•37 citations

Optimal Gaussian measurements for phase estimation in single-mode Gaussian metrology

Changhun Oh, Changhyoup Lee, Carsten Rockstuhl +4 more

Abstract The central issue in quantum parameter estimation is to find out the optimal measurement setup that leads to the ultimate lower bound of an estimation error. We address here a question of whether a Gaussian measurement scheme can achieve the ultimate bound for phase estimation in single-mode Gaussian metrology that exploits single-mode Gaussian probe states in a Gaussian environment. We identify three types of optimal Gaussian measurement setups yielding the maximal Fisher information depending on displacement, squeezing, and thermalization of the probe state. We show that the homodyne measurement attains the ultimate bound for both displaced thermal probe states and squeezed vacuum probe states, whereas for the other single-mode Gaussian probe states, the optimized Gaussian measurement cannot be the optimal setup, although they are sometimes nearly optimal. We then demonstrate that the measurement on the basis of the product quadrature operators $$\hat X\hat P + \hat P\hat X$$ X ̂ P ̂ + P ̂ X ̂ , i.e., a non-Gaussian measurement, is required to be fully optimal.

arXiv:1805.08495•npj Quantum Information•Jan 28, 2019•94 citations
In this paper we study the phase sensitivity of generic linear interferometric schemes using Gaussian resources and measurements. Our formalism is based on the Fisher information. This allows us to separate the contributions of the measurement scheme, the experimental imperfections, and auxiliary systems. We demonstrate the strength of this formalism using a broad class of multimode Gaussian states that includes well-known results from single- and two-mode metrology scenarios. Using this, we prove that input coherent states or squeezing improve upon the nonclassical states proposed in preceding boson-sampling-inspired phase-estimation schemes. We also develop a polychromatic interferometric protocol, demonstrating an enhanced sensitivity with respect to two-mode squeezed-vacuum states, for which the ideal homodyne detection is formally shown to be optimal.
Phase estimation has a wide range of applications. Over the years, several strategies have been studied to improve precision in phase estimation. These strategies include using exotic quantum states to quantum detection schemes. This dissertation summarizes my effort in improving the precision of phase estimation with a linear and nonlinear interferometer. Chapter 1 introduces quantum optics and quantum metrology. I introduce all relevant quantum states of light used. We also look into tools and terminologies of quantum metrology such as Fisher information, shot-noise limit, Heisenberg limit, etc., along with examples of phase estimation with a Mach-Zehnder interferometer. In Chapter 2, I discuss multiple phase estimation using a multimode interferometer. Building upon previous work, our scheme consists of a multimode interferometer with single-photon inputs. By using a quantum Fisher information analysis, we show that our scheme gives a constant improvement over other schemes. We also show that our scheme with photon-number-resolving detection approaches the quantum Cram\'er-Rao bound. Moreover, we also consider the probabilistic nature of photon emission at the input, and we study its effect on phase sensitivity. I discuss phase estimation with SU(1,1) interferometer in Chapter 3. We look at phase sensitivity in this interferometer with different input states. Namely, we consider two different phase estimation scheme, one using thermal and squeezed states, and others using coherent and displaced squeezed states with parity and on-off as a detection scheme. We also look into the effect of photon loss inside the interferometer. In Chapter 4, we revisit phase estimation in SU(1,1) interferometer from the perspective of quantum Fisher information. I discuss in detail a longstanding confusion regarding the use of quantum Fisher information in SU(1,1) interferometer. We show that phase averaging or quantum Fisher information matrix method is needed in general for calculating the phase sensitivity which resolves inconsistencies reported in previously published articles.
We address a phase estimation scheme using Gaussian states in the presence of non-Gaussian phase noise. At variance with previous analysis, we analyze situations in which the noise occurs before encoding phase information. In particular, we study how squeezing may be profitably used before or after phase diffusion. Our results show that squeezing the probe after the noise greatly enhances the sensitivity of the estimation scheme, as witnessed by the increase of the quantum Fisher information. We then consider a realistic setup in which homodyne detection is employed at the measurement stage, and we address its optimality as well as its performance in the two different scenarios.
We study quantum phase estimation using multimode non-Gaussian states to investigate quantum enhancement of measurement precision due to the characteristics of multipartite quantum entanglement. We consider two prototypical classes of multipartite entangled states, namely, GHZ-type and W-type entangled states of N optical modes and obtain an optimal configuration for each case by dividing N modes into two parts, one sent to phase-region and the other to empty region. In the lossless regime, both classes exhibit the Heisenberg scaling of quantum Fisher information (QFI) with input energy while the metrological advantage using larger-mode multipartite entanglement appears only in W-type states. We extend our analysis to include photon loss under practical measurement schemes, i.e. Fourier-assisted photon-counting and homodyne detection, and show to what extent the Fisher information under each measurement scheme can approach the ultimate QFI beyond the standard quantum limit.
Bounds on the ultimate precision attainable in the estimation of a parameter in Gaussian quantum metrology are obtained when the average number of bosonic probes is fixed.We identify the optimal input probe state among generic (mixed in general) Gaussian states with a fixed average number of probe photons for the estimation of a parameter contained in a generic multimode interferometric optical circuit, namely, a passive linear circuit preserving the total number of photons.The optimal Gaussian input state is essentially a single-mode squeezed vacuum, and the ultimate precision is achieved by a homodyne measurement on the single mode.We also reveal the best strategy for the estimation when we are given L identical target circuits and are allowed to apply passive linear controls in between with an arbitrary number of ancilla modes introduced.
We study the sensitivity of phase estimation in a lossy Mach-Zehnder interferometer (MZI) using two general, and practical, resources generated by a laser and a nonlinear optical medium with passive optimal elements, which are readily available in the laboratory: One is a two-mode separable coherent and squeezed vacuum state at a beam splitter and the other is a two-mode squeezed vacuum state. In view of the ultimate precision given by quantum Fisher information, we show that the two-mode squeezed vacuum state can achieve a lower bound of estimation error than the coherent and squeezed vacuum state under a photon-loss channel. We further consider practical measurement schemes, homodyne detection and photon number resolving detection (PNRD), to characterize the accuracy of phase estimation in reality and find that the coherent and squeezed vacuum state largely achieves a lower bound than the two-mode squeezed vacuum in the lossy MZI while maintaining quantum enhancement over the shot-noise limit. By comparing homodyne detection and PNRD, we demonstrate that quadrature measurement with homodyne detection is more robust against photon loss than parity measurement with PNRD. We also show that double homodyne detection can provide a better tool for phase estimation than single homodyne detection against photon loss.
Abstract The central issue in quantum parameter estimation is to find out the optimal measurement setup that leads to the ultimate lower bound of an estimation error. We address here a question of whether a Gaussian measurement scheme can achieve the ultimate bound for phase estimation in single-mode Gaussian metrology that exploits single-mode Gaussian probe states in a Gaussian environment. We identify three types of optimal Gaussian measurement setups yielding the maximal Fisher information depending on displacement, squeezing, and thermalization of the probe state. We show that the homodyne measurement attains the ultimate bound for both displaced thermal probe states and squeezed vacuum probe states, whereas for the other single-mode Gaussian probe states, the optimized Gaussian measurement cannot be the optimal setup, although they are sometimes nearly optimal. We then demonstrate that the measurement on the basis of the product quadrature operators X^P^+P^X^\hat X\hat P + \hat P\hat XX^P^+P^X^ X ̂ P ̂ + P ̂ X ̂ , i.e., a non-Gaussian measurement, is required to be fully optimal.