Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2008.05234 · PRX Quantum

Experimental Estimation of Quantum State Properties from Classical Shadows

G. I. Struchalin, Я.А. Загоровский, E. V. Kovlakov, Stanislav S. Straupe, S. P. Kulik

Published Jan 13, 2021• 103 citations
arXivHTMLPDF

Abstract

Experimental implementation of ``shadow tomography'': Using a limited number of measurements, the method is demonstrated to outperform conventional state reconstruction of a system's property, such as fidelity.
DOI
10.1103/prxquantum.2.010307

Related papers

Shadow Tomography on General Measurement Frames

Luca Innocenti, Salvatore Lorenzo, I. Palmisano +4 more

The interplay between measurements, reconstructed observables, and the estimators used to process measurement outcomes is examined in a framework that connects shadow tomography with the general theory of measurement frames.

arXiv:2301.13229•PRX Quantum•Nov 20, 2023•36 citations

A computationally efficient approach to quantum state reconstruction using robust classical shadows

Sanjay Sharma, Shyam Akashe, Govind Murari Upadhyay +1 more

Quantum state tomography is a fundamental technique for characterizing quantum systems, but its scalability remains a significant challenge. This paper investigates an efficient alternative using classical shadows to reconstruct a Bell state with high fidelity. Classical shadows provide a compressed representation of a quantum state using randomized measurements, reducing the measurement complexity compared to full quantum tomography when full state reconstruction is not required. We employed a quantum circuit to generate a Bell state and utilize 1000 snapshots to construct its classical shadow. The reconstructed density matrix is evaluated using fidelity and norm difference metrics against the ideal Bell state. Our analysis demonstrates that as the number of snapshots increases, the fidelity of reconstruction stabilizes around 0.98-1.0, with the norm difference decreasing accordingly. The results also confirm the convergence of reconstructed states towards the ideal Bell state, highlighting the efficiency and accuracy of classical shadows in quantum state estimation. Shallow shadow tomography uses shallow random circuits to estimate global quantum state properties on noisy hardware. By combining low-depth entangling gates with randomized measurements and noise-aware postprocessing, it reduces sample complexity compared to Pauli shadows while remaining experimentally feasible. Recent experiments on superconducting processors confirmed up to fivefold measurement savings.

Scientific Reports•Feb 2, 2026•0 citations

Shadow tomography of quantum states with prediction

Jiyu Jiang, Zongqi Wan, Tongyang Li +2 more

Frontiers of Computer Science•Dec 16, 2024•0 citations

Regularizing least squares quantum state tomography with classical shadows

Zhihui Zhu, Joseph M. Lukens, Brian T. Kirby

Classical shadows herald remarkable opportunities for resource-efficient quantum estimation. Although superficially disconnected from traditional inference methods, we show how classical shadows fit under a larger umbrella of least squares regularization, revealing tradeoffs with related methods.

Conference on Lasers and Electro-Optics•Jan 1, 2025•0 citations

Scalable and Flexible Classical Shadow Tomography with Tensor Networks

Ahmed A. Akhtar, Hong-Ye Hu, Yi‐Zhuang You

Classical shadow tomography is a powerful randomized measurement protocol for predicting many properties of a quantum state with few measurements. Two classical shadow protocols have been extensively studied in the literature: the single-qubit (local) Pauli measurement, which is well suited for predicting local operators but inefficient for large operators; and the global Clifford measurement, which is efficient for low-rank operators but infeasible on near-term quantum devices due to the extensive gate overhead. In this work, we demonstrate a scalable classical shadow tomography approach for generic randomized measurements implemented with finite-depth local Clifford random unitary circuits, which interpolates between the limits of Pauli and Clifford measurements. The method combines the recently proposed locally-scrambled classical shadow tomography framework with tensor network techniques to achieve scalability for computing the classical shadow reconstruction map and evaluating various physical properties. The method enables classical shadow tomography to be performed on shallow quantum circuits with superior sample efficiency and minimal gate overhead and is friendly to noisy intermediate-scale quantum (NISQ) devices. We show that the shallow-circuit measurement protocol provides immediate, exponential advantages over the Pauli measurement protocol for predicting quasi-local operators. It also enables a more efficient fidelity estimation compared to the Pauli measurement.

arXiv:2209.02093•Quantum•Jun 1, 2023•76 citations

Experimental Direct Characterization of a Quantum Process

Robert B. A. Adamson, Adam Michael Steinberg

We present the first experimental implementation of Direct Quantum Process Tomography. Direct tomography uses ideas from quantum error correction to reduce the number of experimental configurations required to characterize a quantum process.

International Conference on Quantum Information•Jan 1, 2007•0 citations
Quantum state tomography is a fundamental technique for characterizing quantum systems, but its scalability remains a significant challenge. This paper investigates an efficient alternative using classical shadows to reconstruct a Bell state with high fidelity. Classical shadows provide a compressed representation of a quantum state using randomized measurements, reducing the measurement complexity compared to full quantum tomography when full state reconstruction is not required. We employed a quantum circuit to generate a Bell state and utilize 1000 snapshots to construct its classical shadow. The reconstructed density matrix is evaluated using fidelity and norm difference metrics against the ideal Bell state. Our analysis demonstrates that as the number of snapshots increases, the fidelity of reconstruction stabilizes around 0.98-1.0, with the norm difference decreasing accordingly. The results also confirm the convergence of reconstructed states towards the ideal Bell state, highlighting the efficiency and accuracy of classical shadows in quantum state estimation. Shallow shadow tomography uses shallow random circuits to estimate global quantum state properties on noisy hardware. By combining low-depth entangling gates with randomized measurements and noise-aware postprocessing, it reduces sample complexity compared to Pauli shadows while remaining experimentally feasible. Recent experiments on superconducting processors confirmed up to fivefold measurement savings.
Classical shadow tomography is a powerful randomized measurement protocol for predicting many properties of a quantum state with few measurements. Two classical shadow protocols have been extensively studied in the literature: the single-qubit (local) Pauli measurement, which is well suited for predicting local operators but inefficient for large operators; and the global Clifford measurement, which is efficient for low-rank operators but infeasible on near-term quantum devices due to the extensive gate overhead. In this work, we demonstrate a scalable classical shadow tomography approach for generic randomized measurements implemented with finite-depth local Clifford random unitary circuits, which interpolates between the limits of Pauli and Clifford measurements. The method combines the recently proposed locally-scrambled classical shadow tomography framework with tensor network techniques to achieve scalability for computing the classical shadow reconstruction map and evaluating various physical properties. The method enables classical shadow tomography to be performed on shallow quantum circuits with superior sample efficiency and minimal gate overhead and is friendly to noisy intermediate-scale quantum (NISQ) devices. We show that the shallow-circuit measurement protocol provides immediate, exponential advantages over the Pauli measurement protocol for predicting quasi-local operators. It also enables a more efficient fidelity estimation compared to the Pauli measurement.