arXiv:2008.04360 · Physical Review Letters

Two-Carrier Scheme: Evading the 3 dB Quantum Penalty of Heterodyne Readout in Gravitational-Wave Detectors

Teng Zhang, Philip Jones, J. Smetana, Haixing Miao, Д. В. Мартынов, A. Freise, S. W. Ballmer

Published Jun 1, 2021• 10 citations
arXivHTMLPDF

Abstract

Precision measurements using a traditional heterodyne readout suffer a 3 dB quantum noise penalty compared with a homodyne readout. The extra noise is caused by the quantum fluctuations in the image vacuum. We propose a two-carrier gravitational-wave detector design that evades the 3 dB quantum penalty of the heterodyne readout. We further propose a new way of realizing frequency-dependent squeezing utilizing two-mode squeezing in our scheme. It naturally achieves more precise audio frequency signal measurements with radio frequency squeezing. In addition, the detector is compatible with other quantum nondemolition techniques.

DOI
10.1103/physrevlett.126.221301

Related papers

Quantum squeezing schemes for heterodyne readout

Teng Zhang, Д. В. Мартынов, A. Freise +1 more

Advanced gravitational-wave detectors are limited by quantum noise in their most sensitive frequency band. Quantum noise suppression techniques, such as the application of the quantum squeezed state of light, have been actively studied in the context of homodyne readouts. In this paper, we consider quantum squeezing schemes for the heterodyne readouts. This is motivated by a successful suppression of the higher-order-mode content by stable recycling cavities in advanced detectors. The heterodyne readout scheme requires precise tuning of the interferometer parameters and a broadband squeezing source, but is conceptually simple and elegant. We further show that it is compatible with the frequency-dependent squeezing, which reduces both the shot noise and the radiation-pressure noise. We propose a test of the heterodyne readout with squeezing in Advanced LIGO. This can serve as a pathfinder not only for the implementation in future detectors, such as the Einstein Telescope and Cosmic Explorer, but also for general high-precision optical measurements.

arXiv:2004.10503•Physical review. D/Physical review. D.•Jun 25, 2020•7 citations

Quantum Enhanced Balanced Heterodyne Readout for Differential Interferometry

Daniel W. Gould, V. B. Adya, S. Chua +8 more

Conventional heterodyne readout schemes are now under reconsideration due to the realization of techniques to evade its inherent 3 dB signal-to-noise penalty. The application of high-frequency, quadrature-entangled, two-mode squeezed states can further improve the readout sensitivity of audio-band signals. In this Letter, we experimentally demonstrate quantum-enhanced heterodyne readout of two spatially distinct interferometers with direct optical signal combination, circumventing the 3 dB heterodyne signal-to-noise penalty. Applying a high-frequency, quadrature-entangled, two-mode squeezed state, we show further signal-to-noise improvement of an injected audio band signal of 3.5 dB. This technique is applicable for quantum-limited high-precision experiments, with application to searches for quantum gravity, searches for dark matter, gravitational wave detection, and wavelength-multiplexed quantum communication.

arXiv:2401.04940•Physical Review Letters•Aug 8, 2024•10 citations

Advanced techniques for squeezed-light-enhanced gravitational-wave detection

J. Gniesmer

Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.

•Jan 1, 2019•0 citations

Phase-sensitive heterodyne detection of two-mode squeezed light without noise penalty

Boya Xie, Peng Yang, Sheng Feng

Squeezed states of light can be detected for precision measurements with a heterodyne detector by use of a bichromatic field as the local oscillator, due to the phase-sensitive nature of the device. However, divergence consists of the theoretical description of the quantum noise performance of this detector. Two existing theoretical models are briefly reviewed, with one model predicting a 3 dB quantum noise floor change in detection of two-mode squeezed light if the local oscillator is replaced by a monochromatic one, whereas the other model foretells the same noise floor no matter which local oscillator is used. An experiment on heterodyne detection of two-mode squeezed light is carried out to put the two models under test. No significant difference in the noise floor level is observed between the two detectors, showing the noiseless property of both detectors. This work should be of importance for the understanding of noise origin in optical detection and of great interest in practical application for squeezing-enhanced audio band gravitational-wave signal searching.

Journal of the Optical Society of America B•Sep 4, 2018•10 citations

Photodetection method using unbalanced sidebands for squeezed quantum noise in a gravitational wave interferometer

Kentaro Somiya

Homodyne detection is one of the ways to circumvent the standard quantum limit by changing the readout phase of a gravitational wave detector. In this paper it is shown that the readout phase can also be changed by the radio-frequency heterodyne detection scheme that is generally used in present detectors.

arXiv:gr-qc/0208029•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Jun 5, 2003•8 citations

Squeezed states for advanced gravitational wave detectors

Eric Glenn Oelker

Quantum vacuum fluctuations impose strict limits on precision displacement measurements, those of interferometric gravitational-wave detectors among them. Introducing squeezed states into an interferometer's readout port can improve the sensitivity of the instrument, leading to richer astrophysical observations. In recent years, this technique has been used to improve the sensitivity of the GEO600 [1011 and the Initial LIGO detector at Hanford, WA [102]. Squeezed states could be employed in advanced gravitational-wave detectors, such as Advanced LIGO, to further push the limits of the observable gravitational wave universe. To maximize the benefit from squeezing, environmentally induced disturbances such as back scattering and angular jitter need to be mitigated. Also, optomechanical interactions dictate that the quadrature of the squeezed vacuum state must rotate by 900 at around 50 Hz in order to achieve a broadband sensitivity improvement for Advanced LIGO. In this thesis we describe a series of experiments that lead to a ultra-high vacuum (UHV) compatible, low phase noise, and frequency-dependent squeezed vacuum source required for Advanced LIGO and future gravitational-wave detectors. In order to develop the required technology, two proof-of-principal experiments were conducted. In the first experiment, we built a UHV compatible squeezed vacuum source and homodyne readout and operated them in UHV conditions. We also commissioned a control scheme that achieved a record low 1.30-7 mrad of phase noise. This is a nearly tenfold improvement over previously reported measurements with audio-band squeezed vacuum sources. In the second experiment we used a 2-m-long, high-finesse optical resonator to produce frequency-dependent squeezed quadrature rotation around 1.2kHz. This demonstration of audio-band frequency-dependent squeezing uses technology and methods that are scalable to the required rotation frequency for Advance LIGO, firmly establishing the viability of this technique for application in current and future gravitational-wave detectors. We conclude with a discussion of the implications of these results for squeezing enhancement in Advanced LIGO and beyond.

•Jan 1, 2016•2 citations
Precision measurements using a traditional heterodyne readout suffer a 3 dB quantum noise penalty compared with a homodyne readout. The extra noise is caused by the quantum fluctuations in the image vacuum. We propose a two-carrier gravitational-wave detector design that evades the 3 dB quantum penalty of the heterodyne readout. We further propose a new way of realizing frequency-dependent squeezing utilizing two-mode squeezing in our scheme. It naturally achieves more precise audio frequency signal measurements with radio frequency squeezing. In addition, the detector is compatible with other quantum nondemolition techniques.
Advanced gravitational-wave detectors are limited by quantum noise in their most sensitive frequency band. Quantum noise suppression techniques, such as the application of the quantum squeezed state of light, have been actively studied in the context of homodyne readouts. In this paper, we consider quantum squeezing schemes for the heterodyne readouts. This is motivated by a successful suppression of the higher-order-mode content by stable recycling cavities in advanced detectors. The heterodyne readout scheme requires precise tuning of the interferometer parameters and a broadband squeezing source, but is conceptually simple and elegant. We further show that it is compatible with the frequency-dependent squeezing, which reduces both the shot noise and the radiation-pressure noise. We propose a test of the heterodyne readout with squeezing in Advanced LIGO. This can serve as a pathfinder not only for the implementation in future detectors, such as the Einstein Telescope and Cosmic Explorer, but also for general high-precision optical measurements.
Conventional heterodyne readout schemes are now under reconsideration due to the realization of techniques to evade its inherent 3 dB signal-to-noise penalty. The application of high-frequency, quadrature-entangled, two-mode squeezed states can further improve the readout sensitivity of audio-band signals. In this Letter, we experimentally demonstrate quantum-enhanced heterodyne readout of two spatially distinct interferometers with direct optical signal combination, circumventing the 3 dB heterodyne signal-to-noise penalty. Applying a high-frequency, quadrature-entangled, two-mode squeezed state, we show further signal-to-noise improvement of an injected audio band signal of 3.5 dB. This technique is applicable for quantum-limited high-precision experiments, with application to searches for quantum gravity, searches for dark matter, gravitational wave detection, and wavelength-multiplexed quantum communication.
Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.
Squeezed states of light can be detected for precision measurements with a heterodyne detector by use of a bichromatic field as the local oscillator, due to the phase-sensitive nature of the device. However, divergence consists of the theoretical description of the quantum noise performance of this detector. Two existing theoretical models are briefly reviewed, with one model predicting a 3 dB quantum noise floor change in detection of two-mode squeezed light if the local oscillator is replaced by a monochromatic one, whereas the other model foretells the same noise floor no matter which local oscillator is used. An experiment on heterodyne detection of two-mode squeezed light is carried out to put the two models under test. No significant difference in the noise floor level is observed between the two detectors, showing the noiseless property of both detectors. This work should be of importance for the understanding of noise origin in optical detection and of great interest in practical application for squeezing-enhanced audio band gravitational-wave signal searching.
Quantum vacuum fluctuations impose strict limits on precision displacement measurements, those of interferometric gravitational-wave detectors among them. Introducing squeezed states into an interferometer's readout port can improve the sensitivity of the instrument, leading to richer astrophysical observations. In recent years, this technique has been used to improve the sensitivity of the GEO600 [1011 and the Initial LIGO detector at Hanford, WA [102]. Squeezed states could be employed in advanced gravitational-wave detectors, such as Advanced LIGO, to further push the limits of the observable gravitational wave universe. To maximize the benefit from squeezing, environmentally induced disturbances such as back scattering and angular jitter need to be mitigated. Also, optomechanical interactions dictate that the quadrature of the squeezed vacuum state must rotate by 900 at around 50 Hz in order to achieve a broadband sensitivity improvement for Advanced LIGO. In this thesis we describe a series of experiments that lead to a ultra-high vacuum (UHV) compatible, low phase noise, and frequency-dependent squeezed vacuum source required for Advanced LIGO and future gravitational-wave detectors. In order to develop the required technology, two proof-of-principal experiments were conducted. In the first experiment, we built a UHV compatible squeezed vacuum source and homodyne readout and operated them in UHV conditions. We also commissioned a control scheme that achieved a record low 1.30-7 mrad of phase noise. This is a nearly tenfold improvement over previously reported measurements with audio-band squeezed vacuum sources. In the second experiment we used a 2-m-long, high-finesse optical resonator to produce frequency-dependent squeezed quadrature rotation around 1.2kHz. This demonstration of audio-band frequency-dependent squeezing uses technology and methods that are scalable to the required rotation frequency for Advance LIGO, firmly establishing the viability of this technique for application in current and future gravitational-wave detectors. We conclude with a discussion of the implications of these results for squeezing enhancement in Advanced LIGO and beyond.