We present experimental and theoretical results on a new interferometer topology that nests a SU(2) interferometer, e.g., a Mach-Zehnder or Michelson interferometer, inside a SU(1,1) interferometer, i.e., a Mach-Zehnder interferometer with parametric amplifiers in place of beam splitters. This SU(2)-in-SU(1,1) nested interferometer (SISNI) simultaneously achieves a high signal-to-noise ratio (SNR), sensitivity beyond the standard quantum limit (SQL) and tolerance to photon losses external to the interferometer, e.g., in detectors. We implement a SISNI using parametric amplification by four-wave mixing (FWM) in Rb vapor and a laser-fed Mach-Zehnder SU(2) interferometer. We observe path-length sensitivity with SNR 2.2 dB beyond the SQL at power levels (and thus SNR) 2 orders of magnitude beyond those of previous loss-tolerant interferometers. We find experimentally the optimal FWM gains and find agreement with a minimal quantum noise model for the FWM process. The results suggest ways to boost the in-practice sensitivity of high-power interferometers, e.g., gravitational wave interferometers, and may enable high-sensitivity, quantum-enhanced interferometry at wavelengths for which efficient detectors are not available.
We present experimental and theoretical results on a new interferometer topology that nests a SU(2) interferometer, e.g., a Mach-Zehnder or Michelson interferometer, inside a SU(1,1) interferometer, i.e., a Mach-Zehnder interferometer with parametric amplifiers in place of beam splitters. This SU(2)-in-SU(1,1) nested interferometer (SISNI) simultaneously achieves a high signal-to-noise ratio (SNR), sensitivity beyond the standard quantum limit (SQL) and tolerance to photon losses external to the interferometer, e.g., in detectors. We implement a SISNI using parametric amplification by four-wave mixing (FWM) in Rb vapor and a laser-fed Mach-Zehnder SU(2) interferometer. We observe path-length sensitivity with SNR 2.2 dB beyond the SQL at power levels (and thus SNR) 2 orders of magnitude beyond those of previous loss-tolerant interferometers. We find experimentally the optimal FWM gains and find agreement with a minimal quantum noise model for the FWM process. The results suggest ways to boost the in-practice sensitivity of high-power interferometers, e.g., gravitational wave interferometers, and may enable high-sensitivity, quantum-enhanced interferometry at wavelengths for which efficient detectors are not available.
The use of squeezing and entanglement allows advanced interferometers to detect signals that would otherwise be buried in quantum mechanical noise. High sensitivity instruments including magnetometers and gravitational wave detectors have shown enhanced signal-to-noise ratio (SNR) by injecting single-mode squeezed light into SU(2) interferometers, e.g. the Mach-Zehnder or Michelson topologies. The quantum enhancement in this approach is sensitive to losses, which break the fragile quantum correlations in the squeezed state. In contrast, SU(1,1) interferometers achieve quantum enhancement by noiseless amplification; they noiselessly increase the signal rather than reducing the quantum noise. Prior work on SU(1,1) interferometers has shown quantum-enhanced SNR11 and insensitivity to losses but to date has been limited to low powers and thus low SNR. Here we introduce a new interferometer topology, the SU(2)-in-SU(1,1) nested interferometer, that combines quantum enhancement, the high SNR possible with a SU(2) interferometer, and the loss tolerance of the SU(1,1) approach. We implement this interferometer using four-wave mixing in a hot atomic vapor and demonstrate 2:2(5) dB of quantum SNR enhancement, in a system with a phase variance nearly two orders of magnitude below that of any previous loss-tolerant enhancement scheme. The new interferometer enables new possibilities such as beyond-shot-noise sensing with wavelengths for which efficient detectors are not available.
A nonlinear interferometer uses nonlinear elements as beam splitters to split and to recombine optical waves for interference. As a result, the interference fringe size has a nonlinear dependence on the intensity of the field for phase sensing and leads to an enhanced phase signal. In this paper, a practical scheme of nonlinear interferometry for precision phase measurement is analyzed with parametric amplifiers as the nonlinear beam splitters. It is found that the signal due to phase shift is enhanced by a factor of the amplification gain as compared to a linear interferometer with the same phase-sensing light intensity while the quantum noise is kept at the vacuum level, thus, effectively increasing the signal-to-noise ratio (SNR) beyond the standard quantum limit. Furthermore, the scheme is not as sensitive to the detection loss as the linear scheme with a squeezed state for noise reduction. However, losses inside the interferometer limit the enhancement factor in SNR. We apply the concept to a Michelson interferometer but with parametric amplifiers involved for gravitational-wave detection. We find that effective power is increased by the gain of the amplifiers without actually increasing the cycling power inside the interferometer. Furthermore, the full benefits with squeezed input and variational output or the combination of a quantum nondemolition interferometer for sensitivity beyond the standard quantum limit apply here with even better results. Such a nonlinear interferometer will find wide applications in precision measurements.
Quantum-enhanced precision measurements have emerged as one of the most useful applications of quantum optics. Exploiting quantum states of light and quantum processes, classical measurement limits can be surpassed, leading to improvements in areas including clocks, spectroscopy, magnetometry, and imaging. One measurement where straightforward quantum enhancements are possible is phase sensing with an interferometer. One can inject squeezed vacuum states into the dark port of the beamsplitter in a traditional interferometer to reduce the quantum noise and reach phase sensitivities beyond the shot noise limit. An alternate approach is to replace the beamsplitters of an interferometer with nonlinear parametric amplifiers, which produce nonclassical states of light that can be used to surpass classical performance. This so called SU(1,1) interferometer can theoretically approach sensitivities that scale as 1/n, the Heisenberg limit where n is the interior phase sensing photon number, compared to the shot noise limit of 1/ √ n for a traditional interferometer [1]. I will present our group’s experimental progress in testing a Mach-Zender SU(1,1) interferometer using four-wave mixers (4WMs) in hot Rb atoms as the parametric beamsplitters. The 4WM process generates entangled twin beams which serve as the two arms of the interferometer, and are then recombined in a second 4WM cell, resulting in a phase-sensitive output. We will extend the work done on this interferometer [2, 3] by performing a detailed analysis of the output signal to noise through homodyne measurements, and will attempt to observe the better-than-shot-noise scaling of the sensitivity. We will also consider the various difficulties of this optical interferometer such as the susceptibility to loss and imperfect mode-matching within the interferometer. Our group is also considering an analogous SU(1,1) interferometer in a cold atom system. Collisions in a spinor Bose-Einstein condensate of sodium atoms give rise to a 4WM process that produces spin states of the atoms which are entangled in atom number. These interactions can be controlled to set up an SU(1,1) atom interferometer, where the relevant measurements are now atomic population differences rather than photon intensities. These enhancements can lead to drastic improvements in atomic spin interferometry [3, 4].
Conventional interferometers usually utilize beam splitters for wave splitting and recombination. These interferometers are widely used for precision measurement. Their sensitivity for phase measurement is limited by the shot noise, which can be suppressed with squeezed states of light. Here we study a new type of interferometer in which the beam splitting and recombination elements are parametric amplifiers. We observe an improvement of 4.1±0.3 dB in signal-to-noise ratio compared with a conventional interferometer under the same operating condition, which is a 1.6-fold enhancement in rms phase measurement sensitivity beyond the shot noise limit. The improvement is due to signal enhancement. Combined with the squeezed state technique for shot noise suppression, this interferometer promises further improvement in sensitivity. Furthermore, because nonlinear processes are involved in this interferometer, we can couple a variety of different waves and form new types of hybrid interferometers, opening a door for many applications in metrology. Interferometers play a key role in precision measurements and metrology. Here, the authors demonstrate a new type of interferometer that replaces the standard beam splitter elements with parametric amplifiers, which provides enhanced performance compared with a Mach–Zehnder interferometer.
With the help of quantum entanglement, quantum dense metrology (QDM) is a technique that can make joint estimates of two conjugate quantities such as phase and amplitude modulations of an optical field, with an accuracy beating the standard quantum limit simultaneously. SU(1,1) interferometers (SUIs) can realize QDM with detection loss tolerance but is limited in absolute sensitivity. Here, we present a QDM scheme with a linear or SU(2) interferometer nested inside an SUI. By using a degenerate SUI and controlling the phase angle of the phase-sensitive amplifiers in the SUI, we can achieve the optimum quantum enhancement in the measurement precision of an arbitrary mixture of phase and amplitude modulation.
Michelson interferometer can be applied to not only the building block of the fundamental research of physics, but also the precise measurement, such as the direct observation of gravity wave signal. Therefore, high performance Michelson interferometer is the key step towards the implementation of direct observation of weak gravity wave signal. Recently, the vacuum noise was reduced by injecting squeezed vacuum into the unused port of Michelson interferomter, and the phase signal optical field in Mach-Zender interferometer is amplified based on the four-wave mixing in hot Rubidium atom. Here we study high sensitivity quantum Michelson interferometer. In the Michelson interferometer, the linear optical beam splitter is replaced by a non-degenerated optical parametric amplifier to realize the splitting and combining of optical fields, and the squeezed vacuum is also injected into the unused port of interferomter, so that the high signal-to-noise ratio and high sensitivity of phase measurement can be realized. Due to the inevitable optical losses, the losses inside and outside the Michelson interferometer are considered in our theoretical model. We investigate the influences of the losses inside and outside the Michelson interferometer on the sensitivity of phase measurement. By theoretical calculation, we analyze the dependence of sensitivity of phase measurement on system parameters, such as intensity of optical fields for phase sensing, gain factor of non-degenerated optical parametric amplifier, the losses inside and outside the Michelson interferometer, and the squeezing parameter of input squeezed vacuum, and thus the condition of high sensitivity nonlinear Michelson interferometer can be obtained. In a broad system parametric range, the quantum Michaleson interferometer can surpass standard quantum limit, and the nonlinear Michaleson interferometer with squeezed state injection can provide the optimal sensitivity for phase measurement. The nonlinear Michelson interferometer with squeezed state is suitable for weak signal measurement. While the gain factor of non-degenerated optical parametric amplifier is large enough, the nonlinear Michelson interferometer without injecting the squeezed vacuum can still reach the optimal sensitivity, which reduces the use of quantum resources. When the phase sensing optical field is strong, the linear Michelson interferometer with injecting the squeezed vacuum can also reach the optimal sensitivity, and the sensitivity is robust for both losses inside and outside the interferometer. All the kinds of interferometers are more sensitive to the loss inside the interferometer than outside the interferometer, and the sensitivity of phase measurement can be improved by reducing the loss inside the interferometer. Our result provides direct reference of experimental implementation of high performance interferometer for high precision quantum metrology.