Ionizing radiation in the form of
α,
β,
γ, and additional high-energy particles can induce decoherence via phonon and quasiparticle poisoning in superconducting qubits. Recent studies have explored this effect using cosmic rays or controlled radioactive sources held in the proximity of a qubit package, and have concluded that reductions in such ``external'' environmental radiation may benefit stable operation of qubit devices. However, the effect of long-lived, unstable daughters of
222Rn that ``plate out'' directly on device and packaging surfaces has not been as extensively explored. This plate-out process, well-known to the dark matter direct detection field, occurs throughout the fabrication and testing lifecycle of a device and (separately) its packaging, and produces a local source of
α-decays which can remain active for decades. As this scales with chip area, understanding and managing this source of ionizing radiation is relevant for successfully scaling quantum computing architectures to larger numbers of qubits in a radiation-robust way. We present a setup capable of accelerating and enhancing radon daughter plateout by a factor of
7×104 over ambient, in order to study, \textit{in situ}, the impact of these events on superconducting qubits. We also provide outlook on the potential impact of this source of ionizing radiation on current and future qubit arrays.
We measure the effect of ionizing radiation on superconducting qubits with a timing resolution of 1
μs using microwave kinetic inductance detectors (MKIDs) fabricated on the same substrate. We observe no correlation between two-level system (TLS) scrambling events and ionizing radiation events detected with the MKIDs, suggesting TLS scrambling events may not arise from ionizing radiation and instead the previously reported apparent correlation may be due to events without sufficient energy to trigger our MKIDs. We characterize the fast-time system recovery of transmons following a radiation event, where we observe the recovery of the enhanced qubit relaxation and excitation to be well-described by an exponential recovery to the baseline quasiparticle density, with a characteristic time of
13±1 μs, and a peak quasiparticle density at the junction per deposited energy of
240/μm3/MeV. The fast recovery is consistent with literature reported values for Nb-based devices with direct injection of 2
ΔAl phonons, demonstrating the recovery is strongly dependent on the proximity of niobium to the junction.