Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1911.04744 · International Journal of Quantum Information

Resolution limits of spatial mode demultiplexing with noisy detection

Yink Loong Len, Chandan Datta, Michal P. Parniak, Konrad Banaszek

Published Jan 31, 2020• 53 citations
arXivHTMLPDF

Abstract

We consider the problem of estimating the spatial separation between two mutually incoherent point light sources using the super-resolution imaging technique based on spatial mode demultiplexing (SPADE) with noisy detectors. We show that in the presence of noise, the resolution of the measurement is limited by the signal-to-noise ratio (SNR) and the minimum resolvable spatial separation has a characteristic dependence of [Formula: see text]. Several detection techniques, including direct photon counting, as well as homodyne and heterodyne detection are considered.

DOI
10.1142/s0219749919410156

Related papers

Spatial-mode demultiplexing for enhanced intensity and distance measurement

Luigi Santamaria Amato, Deborah Katia Pallotti, Mario Siciliani de Cumis +2 more

Spatial-mode demultiplexing (SPADE) has recently been adopted to measure the separation in the transverse plane between two incoherent point-like sources with sub-wavelength separation. It has been argued that this approach may yield extraordinary performances in the photon-counting regime. Here, we explore SPADE as a tool for precision measurements in the regime of bright, incoherent sources. First we analyze the general problem of estimating the second moments of the source's intensity distribution, for an extended incoherent source of any shape. Our theory predicts a substantial improvement in signal-to-noise ratio (SNR) of SPADE over direct imaging in the sub-wavelength regime. Second, we present an experimental application of SPADE to the case of two point-like, bright sources. We demonstrate the use of this setup for the estimation of the transverse separation and for the estimation of the relative intensity, confirming the expected improvement in SNR.

arXiv:2206.05246•Optics Express•Jun 5, 2023•32 citations

Subdiffraction incoherent optical imaging via spatial-mode demultiplexing

Mankei Tsang

I propose a spatial-mode demultiplexing (SPADE) measurement scheme for the far-field imaging of spatially incoherent optical sources. For any object too small to be resolved by direct imaging under the diffraction limit, I show that SPADE can estimate its second or higher moments much more precisely than direct imaging can fundamentally do in the presence of photon shot noise. I also prove that SPADE can approach the optimal precision allowed by quantum mechanics in estimating the location and scale parameters of a subdiffraction object. Realizable with far-field linear optics and photon counting, SPADE is expected to find applications in both fluorescence microscopy and astronomy.

arXiv:1608.03211•New Journal of Physics•Feb 16, 2017•121 citations

Spatial mode demultiplexing imaging in single photon regime

Luigi Santamaria Amato, Fabrizio Sgobba, Cosmo Lupo

The resolution of direct imaging, which is the most widespread technique for remote observation in the optical domain, is fundamentally limited by diffraction. It has been recently shown that the diffraction limit can be overcome, even with passive optics, using interferometric far-field techniques like spatial mode demultiplexing (SPADE). We present our results on sub-diffraction imaging and spectroscopy of a pair of incoherent point-like emitters using SPADE in the single-photon regime. A theoretical analysis provides a comparison with direct imaging and explains the improvement in terms of signal-to-noise ratio. The application of single-photon SPADE for detection of more complex objects beyond a pair of point-emitters is underway for deployment in earth observation and object detection. The results are presented in the framework of the Quantum Imaging for Exoplanet detection (QUEXO) project.

•May 30, 2025•0 citations

Noise-robust discrimination of incoherent point sources with spatial-mode demultiplexing

Jian-Qiang Liu, Chao-Ning Hu, Jun Xin +1 more

We theoretically predict and experimentally demonstrate that a reduced spatial-mode demultiplexing (SPADE) measurement using only the two lowest-order Hermite-Gaussian modes exhibits remarkable robustness against background noise in discriminating between a single source and two incoherent point sources. We establish a theoretical framework incorporating uniform background noise and derive an analytical Chernoff exponent expression, showing that SPADE consistently outperforms direct imaging (DI) across all source separations. Experimental results confirm that SPADE-based hypothesis testing approaches the quantum limit even when the background-to-signal photon ratio per pixel is 0.11. This advantage stems from SPADE's ability to concentrate source information into minimal detection modes, reducing the cumulative background noise impact. Our findings provide a practical detection scheme for applications where background noise is inevitable, such as astronomical observations and quantum sensing.

quant-pharXiv:2608.01765•Optics Express•Aug 4, 2026•1 citation

Application range of crosstalk-affected spatial demultiplexing for resolving separations between unbalanced sources

Tomasz Linowski, Konrad Schlichtholz, Giacomo Sorelli +4 more

Abstract Super resolution is one of the key issues at the crossroads of contemporary quantum optics and metrology. Recently, it was shown that for an idealized case of two balanced sources, spatial mode demultiplexing (SPADE) achieves resolution better than direct imaging even in the presence of measurement crosstalk (Gessner et al 2020 Phys. Rev. Lett. 125 100501). In this work, we consider arbitrarily unbalanced sources and provide a systematic analysis of the impact of crosstalk on the resolution obtained from SPADE. As we dissect, in this generalized scenario, SPADE’s effectiveness depends non-trivially on the strength of crosstalk, relative brightness and the separation between the sources. In particular, for any source imbalance, SPADE performs worse than ideal direct imaging in the asymptotic limit of vanishing source separations. Nonetheless, for realistic values of crosstalk strength, SPADE is still the superior method for several orders of magnitude of source separations.

New Journal of Physics•Oct 1, 2023•15 citations

Superresolving optical ruler based on spatial mode demultiplexing for systems evolving under Brownian motion

Konrad Schlichtholz

The development of super-resolution techniques, i.e., allowing for efficient resolution below the Rayleigh limit, became one of the important branches in contemporary optics and metrology. Recent findings show that perfect spatial mode demultiplexing (SPADE) into Hermite-Gauss modes followed by photon counting enables one to reach the quantum limit of precision in the task of estimation of separation between two weak stationary sources in the sub-Rayleigh regime. In order to check the limitations of the method, various imperfections such as misalignment or crosstalk between the modes were considered. Possible applications of the method in microscopy call for the adaptive measurement scheme, as the position of the measured system can evolve in time, causing non-negligible misalignment. In this paper, we examine the impact of Brownian motion of the center of the system of two weak incoherent sources on adaptive SPADE measurement precision limits. The analysis is carried out using Fisher information, from which the limit of precision can be obtained by Cramér-Rao bound. As a result, we find that Rayleigh's curse is present in such a scenario; however, SPADE measurement can outperform perfect direct imaging. What is more, a suitable adjustment of the measurement time between alignments allows measurement with near-optimal precision.

arXiv:2407.13723•Physics of Fluids•Feb 1, 2025•1 citation
We consider the problem of estimating the spatial separation between two mutually incoherent point light sources using the super-resolution imaging technique based on spatial mode demultiplexing (SPADE) with noisy detectors. We show that in the presence of noise, the resolution of the measurement is limited by the signal-to-noise ratio (SNR) and the minimum resolvable spatial separation has a characteristic dependence of [Formula: see text]. Several detection techniques, including direct photon counting, as well as homodyne and heterodyne detection are considered.
Spatial-mode demultiplexing (SPADE) has recently been adopted to measure the separation in the transverse plane between two incoherent point-like sources with sub-wavelength separation. It has been argued that this approach may yield extraordinary performances in the photon-counting regime. Here, we explore SPADE as a tool for precision measurements in the regime of bright, incoherent sources. First we analyze the general problem of estimating the second moments of the source's intensity distribution, for an extended incoherent source of any shape. Our theory predicts a substantial improvement in signal-to-noise ratio (SNR) of SPADE over direct imaging in the sub-wavelength regime. Second, we present an experimental application of SPADE to the case of two point-like, bright sources. We demonstrate the use of this setup for the estimation of the transverse separation and for the estimation of the relative intensity, confirming the expected improvement in SNR.
I propose a spatial-mode demultiplexing (SPADE) measurement scheme for the far-field imaging of spatially incoherent optical sources. For any object too small to be resolved by direct imaging under the diffraction limit, I show that SPADE can estimate its second or higher moments much more precisely than direct imaging can fundamentally do in the presence of photon shot noise. I also prove that SPADE can approach the optimal precision allowed by quantum mechanics in estimating the location and scale parameters of a subdiffraction object. Realizable with far-field linear optics and photon counting, SPADE is expected to find applications in both fluorescence microscopy and astronomy.
The resolution of direct imaging, which is the most widespread technique for remote observation in the optical domain, is fundamentally limited by diffraction. It has been recently shown that the diffraction limit can be overcome, even with passive optics, using interferometric far-field techniques like spatial mode demultiplexing (SPADE). We present our results on sub-diffraction imaging and spectroscopy of a pair of incoherent point-like emitters using SPADE in the single-photon regime. A theoretical analysis provides a comparison with direct imaging and explains the improvement in terms of signal-to-noise ratio. The application of single-photon SPADE for detection of more complex objects beyond a pair of point-emitters is underway for deployment in earth observation and object detection. The results are presented in the framework of the Quantum Imaging for Exoplanet detection (QUEXO) project.
We theoretically predict and experimentally demonstrate that a reduced spatial-mode demultiplexing (SPADE) measurement using only the two lowest-order Hermite-Gaussian modes exhibits remarkable robustness against background noise in discriminating between a single source and two incoherent point sources. We establish a theoretical framework incorporating uniform background noise and derive an analytical Chernoff exponent expression, showing that SPADE consistently outperforms direct imaging (DI) across all source separations. Experimental results confirm that SPADE-based hypothesis testing approaches the quantum limit even when the background-to-signal photon ratio per pixel is 0.11. This advantage stems from SPADE's ability to concentrate source information into minimal detection modes, reducing the cumulative background noise impact. Our findings provide a practical detection scheme for applications where background noise is inevitable, such as astronomical observations and quantum sensing.
Abstract Super resolution is one of the key issues at the crossroads of contemporary quantum optics and metrology. Recently, it was shown that for an idealized case of two balanced sources, spatial mode demultiplexing (SPADE) achieves resolution better than direct imaging even in the presence of measurement crosstalk (Gessner et al 2020 Phys. Rev. Lett. 125 100501). In this work, we consider arbitrarily unbalanced sources and provide a systematic analysis of the impact of crosstalk on the resolution obtained from SPADE. As we dissect, in this generalized scenario, SPADE’s effectiveness depends non-trivially on the strength of crosstalk, relative brightness and the separation between the sources. In particular, for any source imbalance, SPADE performs worse than ideal direct imaging in the asymptotic limit of vanishing source separations. Nonetheless, for realistic values of crosstalk strength, SPADE is still the superior method for several orders of magnitude of source separations.
The development of super-resolution techniques, i.e., allowing for efficient resolution below the Rayleigh limit, became one of the important branches in contemporary optics and metrology. Recent findings show that perfect spatial mode demultiplexing (SPADE) into Hermite-Gauss modes followed by photon counting enables one to reach the quantum limit of precision in the task of estimation of separation between two weak stationary sources in the sub-Rayleigh regime. In order to check the limitations of the method, various imperfections such as misalignment or crosstalk between the modes were considered. Possible applications of the method in microscopy call for the adaptive measurement scheme, as the position of the measured system can evolve in time, causing non-negligible misalignment. In this paper, we examine the impact of Brownian motion of the center of the system of two weak incoherent sources on adaptive SPADE measurement precision limits. The analysis is carried out using Fisher information, from which the limit of precision can be obtained by Cramér-Rao bound. As a result, we find that Rayleigh's curse is present in such a scenario; however, SPADE measurement can outperform perfect direct imaging. What is more, a suitable adjustment of the measurement time between alignments allows measurement with near-optimal precision.