Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1911.00882 · Nature Communications

Prospects and challenges for squeezing-enhanced optical atomic clocks

Marius Schulte, Christian Lisdat, Piet O. Schmidt, Uwe Sterr, Klemens Hammerer

Published Nov 24, 2020• 71 citations
arXivHTMLPDF

Abstract

Optical atomic clocks are a driving force for precision measurements due to the high accuracy and stability demonstrated in recent years. While further improvements to the stability have been envisioned by using entangled atoms, squeezing the quantum mechanical projection noise, evaluating the overall gain must incorporate essential features of an atomic clock. Here, we investigate the benefits of spin squeezed states for clocks operated with typical Brownian frequency noise-limited laser sources. Based on an analytic model of the closed servo-loop of an optical atomic clock, we report here quantitative predictions on the optimal clock stability for a given dead time and laser noise. Our analytic predictions are in good agreement with numerical simulations of the closed servo-loop. We find that for usual cyclic Ramsey interrogation of single atomic ensembles with dead time, even with the current most stable lasers spin squeezing can only improve the clock stability for ensembles below a critical atom number of about one thousand in an optical Sr lattice clock. Even with a future improvement of the laser performance by one order of magnitude the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers.

DOI
10.1038/s41467-020-19403-7

Related papers

Spin squeezing can only improve clocks with small atom number

Marius Schulte, Christian Lisdat, Piet O. Schmidt +2 more

We show that the stability of an optical atomic clock can only be improved by spin squeezed states for ensembles below a critical particle number. This limitation results from a trade-off between measurement noise and instabilities due to limited laser coherence. Our results apply to the case of cyclic Ramsey interrogations on a single atomic ensemble with dead time between each measurement. The combination of analytical models for projection noise, dead time noise (Dick effect) and laser phase noise allows quantitative predictions of the critical particle number and the optimal clock stability for a given dead time and laser noise. Our analytical predictions are confirmed by numerical simulations of the closed servo loop of an optical atomic clock.

•Nov 3, 2019•0 citations

Entanglement in Ramsey interferometry, optical atomic clocks and trapped ions

Schulte, Marius

This thesis describes new results on the entanglement of atomic spins in Ramsey interferometry, optical atomic clocks and trapped ions. It is divided into three parts: First, we investigate improvements to conventional Ramsey interferometry with entanglement and adding only rotations of the collective spin to adjust the signal and measurement directions. The geometric degrees of freedom, connected to the rotations, are analytically optimized for a large class of generalized Ramsey protocols to allow efficient optimization of all parameters. Besides a unification of existing approaches, the main result is that there is only one new protocol, where a previously unused double inversion is applied. Studies of the local sensitivity show that this protocol reaches the fundamental quantum Fisher information limit and is yet robust against errors during preparation and measurement. In the second section we investigate the conditions under which optical atomic clocks exhibit increased long-term stability when applying weakly entangled, spin squeezed states. We discuss the common case of an atomic clock with a single ensemble, typical Brownian frequency noise and finite dead time. Theoretical modelling of the servo loop allows quantitative predictions of the optimal stability for given values of dead time and laser noise, in very good agreement with numerical simulations of the closed feedback loop. The main result is that, even with the current most stable lasers, the clock stability can only be improved for ensembles below a critical atom number of about one thousand in optical Sr lattice clocks. Even with a future improvement of the laser performance by one order of magnitude, the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers. Thus the last section considers the robust generation of entanglement in ion traps. An error budget including relevant experimental error sources is calculated for state-of-the-art quantum gates, driven by oscillating microwave gradients in surface traps. Amplitude modulation of the driving fields is shown to efficiently counteract the current limitations from motional mode instability. The predicted increase of the gate quality was demonstrated by the group of C. Ospelkaus at PTB Braunschweig, who measured gates with errors as low as ~ 10^(-3). In a similar approach, interactions between spin and motion can also be generated by combining oscillating rf-fields with a static magnetic field gradient. Penning traps designed for precision spectroscopy already feature large magnetic field gradients at the edge of a magnetic bottle configuration. We present parameters and conditions under which laser-free coupling of spin and quantized motion for (anti-)protons is possible at these points, in a step towards quantum logic spectroscopy for (anti-)protons.

•Jan 1, 2020•1 citation

Enhancing Spin Squeezing in Sr Optical Lattice Clock through Digital Noise Reduction

Swerdfeger, Shae

Optical atomic clocks utilizing strontium are the gold standard of timekeeping. Generating entanglement by spin-squeezing has the potential to continue pushing the limits of clock stability below the fundamental performance limit for unentangled ensembles, the standard quantum limit (SQL). One way to do so is by using an optical cavity to transduce interactions between the atoms and to improve the cavity readout, one needs to minimize the noise of the stabilized cavity length. Noise in a control loop can arise from many different sources, including mechanical resonances of the piezo (PZT) used to control the cavity length, so addressing this noise can improve clock stability and maximize the capabilities of quantum sensing. For this project, I measured the transfer function of the piezo-cavity system, inverted this transfer function, and extracted the poles and zeros. I then programmed this tailored digital filter on a Red Pitaya using an open-source Python package, PyRPL. Challenges still remain with the device implementation into the control loop, but afterwards this would ultimately contribute to improved clock precision and attain better spin-squeezing generated by the cavity.

•Apr 9, 2025•0 citations

Impact of non-unitary spin squeezing on atomic clock performance

Boris Braverman, Akio Kawasaki, Vladan Vuletić

Spin squeezing is a form of entanglement that can improve the stability of quantum sensors operating with multiple particles, by inducing inter-particle correlations that redistribute the quantum projection noise. Previous analyses of potential metrological gain when using spin squeezing were performed on theoretically ideal states, without incorporating experimental imperfections or inherent limitations which result in non-unitary quantum state evolution. Here, we show that potential gains in clock stability are substantially reduced when the spin squeezing is non-unitary, and derive analytic formulas for the clock performance as a function of squeezing, excess spin noise, and interferometer contrast. Our results highlight the importance of creating and employing nearly pure entangled states for improving atomic clocks.

arXiv:1806.02161•New Journal of Physics•Oct 1, 2018•35 citations

Spin-squeezing-enhanced optical lattice clocks with 10 − 19 -level differential frequency stability at the averaging time of 1 s

Deshui Yu, Jia Zhang, Tongyan Xia +3 more

Many-body entangled states allow precision measurement beyond the standard quantum limit. Yet they have not been effectively exploited in optical lattice clocks except for proof-of-principle demonstrations. Under the current experimental conditions, taking into account the lattice perturbation, atom-atom interactions, and local oscillator noise, we theoretically evaluate the performance of spin-squeezing-based shallow-lattice Yb optical clocks. The numerical simulation shows that the stability of differential frequency comparison between two Yb ensembles in squeezed spin states potentially accesses the ${10}^{\ensuremath{-}19}$ level at the averaging time of 1 s. The resultant Wineland parameter may be as low as ${\ensuremath{\xi}}_{\text{W}}^{2}=0.027$, corresponding to a reduction of averaging time by a factor of 37, and is limited by the collision-induced degradation of spin squeezing. The metrological gain provided by spin squeezing opens up new opportunities for precision measurement and fundamental physics.

Physical Review A•Jul 1, 2024•4 citations

Extending the fundamental limit of atomic clock stability

Ravid Shaniv, Ayush Agrawal, David B. Hume

Optical atomic clocks have been rapidly developing in recent decades, resulting in major improvements in both precision and accuracy. As a result, they have become instrumental in multiple areas of applied and fundamental research. Despite all atomic frequency references having more than two energy-levels, the commonly used model for evaluating their ultimate limits assumes a two-level atom. This leads to frequency interrogation protocols and theoretical stability bounds that are suboptimal for a true multi-level atom. The most fundamental stability bound assumes two noise sources - quantum projection noise and spontaneous decay from the excited state. In this work, we analyze a model that includes these noise types and is generalized beyond the two-level assumption, where spontaneous decay can branch to more than a single ground state. This model allows for detection and exclusion of atomic frequency interrogations in which the atom decayed, leading to a frequency stability improvement of up to $\approx 4.5 \text{ dB}$ compared with the two-level model. Furthermore, we identify an even greater stability enhancement of $\approx 5.4 \text{ dB}$ for frequency comparisons between atoms in an odd parity Bell state. These enhancements are particularly relevant for the numerous trapped-ion optical clock species that operate close to lifetime-limited stability. We calculate new stability limits for those cases and provide a detailed experimental protocol for frequency interrogation with an $^{27}\text{Al}^{+}$ optical ion clock.

physics.atom-phCross-listedarXiv:2604.01099•Apr 2, 2026•0 citations
Optical atomic clocks are a driving force for precision measurements due to the high accuracy and stability demonstrated in recent years. While further improvements to the stability have been envisioned by using entangled atoms, squeezing the quantum mechanical projection noise, evaluating the overall gain must incorporate essential features of an atomic clock. Here, we investigate the benefits of spin squeezed states for clocks operated with typical Brownian frequency noise-limited laser sources. Based on an analytic model of the closed servo-loop of an optical atomic clock, we report here quantitative predictions on the optimal clock stability for a given dead time and laser noise. Our analytic predictions are in good agreement with numerical simulations of the closed servo-loop. We find that for usual cyclic Ramsey interrogation of single atomic ensembles with dead time, even with the current most stable lasers spin squeezing can only improve the clock stability for ensembles below a critical atom number of about one thousand in an optical Sr lattice clock. Even with a future improvement of the laser performance by one order of magnitude the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers.
We show that the stability of an optical atomic clock can only be improved by spin squeezed states for ensembles below a critical particle number. This limitation results from a trade-off between measurement noise and instabilities due to limited laser coherence. Our results apply to the case of cyclic Ramsey interrogations on a single atomic ensemble with dead time between each measurement. The combination of analytical models for projection noise, dead time noise (Dick effect) and laser phase noise allows quantitative predictions of the critical particle number and the optimal clock stability for a given dead time and laser noise. Our analytical predictions are confirmed by numerical simulations of the closed servo loop of an optical atomic clock.
This thesis describes new results on the entanglement of atomic spins in Ramsey interferometry, optical atomic clocks and trapped ions. It is divided into three parts: First, we investigate improvements to conventional Ramsey interferometry with entanglement and adding only rotations of the collective spin to adjust the signal and measurement directions. The geometric degrees of freedom, connected to the rotations, are analytically optimized for a large class of generalized Ramsey protocols to allow efficient optimization of all parameters. Besides a unification of existing approaches, the main result is that there is only one new protocol, where a previously unused double inversion is applied. Studies of the local sensitivity show that this protocol reaches the fundamental quantum Fisher information limit and is yet robust against errors during preparation and measurement. In the second section we investigate the conditions under which optical atomic clocks exhibit increased long-term stability when applying weakly entangled, spin squeezed states. We discuss the common case of an atomic clock with a single ensemble, typical Brownian frequency noise and finite dead time. Theoretical modelling of the servo loop allows quantitative predictions of the optimal stability for given values of dead time and laser noise, in very good agreement with numerical simulations of the closed feedback loop. The main result is that, even with the current most stable lasers, the clock stability can only be improved for ensembles below a critical atom number of about one thousand in optical Sr lattice clocks. Even with a future improvement of the laser performance by one order of magnitude, the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers. Thus the last section considers the robust generation of entanglement in ion traps. An error budget including relevant experimental error sources is calculated for state-of-the-art quantum gates, driven by oscillating microwave gradients in surface traps. Amplitude modulation of the driving fields is shown to efficiently counteract the current limitations from motional mode instability. The predicted increase of the gate quality was demonstrated by the group of C. Ospelkaus at PTB Braunschweig, who measured gates with errors as low as ~ 10^(-3). In a similar approach, interactions between spin and motion can also be generated by combining oscillating rf-fields with a static magnetic field gradient. Penning traps designed for precision spectroscopy already feature large magnetic field gradients at the edge of a magnetic bottle configuration. We present parameters and conditions under which laser-free coupling of spin and quantized motion for (anti-)protons is possible at these points, in a step towards quantum logic spectroscopy for (anti-)protons.
Optical atomic clocks utilizing strontium are the gold standard of timekeeping. Generating entanglement by spin-squeezing has the potential to continue pushing the limits of clock stability below the fundamental performance limit for unentangled ensembles, the standard quantum limit (SQL). One way to do so is by using an optical cavity to transduce interactions between the atoms and to improve the cavity readout, one needs to minimize the noise of the stabilized cavity length. Noise in a control loop can arise from many different sources, including mechanical resonances of the piezo (PZT) used to control the cavity length, so addressing this noise can improve clock stability and maximize the capabilities of quantum sensing. For this project, I measured the transfer function of the piezo-cavity system, inverted this transfer function, and extracted the poles and zeros. I then programmed this tailored digital filter on a Red Pitaya using an open-source Python package, PyRPL. Challenges still remain with the device implementation into the control loop, but afterwards this would ultimately contribute to improved clock precision and attain better spin-squeezing generated by the cavity.
Spin squeezing is a form of entanglement that can improve the stability of quantum sensors operating with multiple particles, by inducing inter-particle correlations that redistribute the quantum projection noise. Previous analyses of potential metrological gain when using spin squeezing were performed on theoretically ideal states, without incorporating experimental imperfections or inherent limitations which result in non-unitary quantum state evolution. Here, we show that potential gains in clock stability are substantially reduced when the spin squeezing is non-unitary, and derive analytic formulas for the clock performance as a function of squeezing, excess spin noise, and interferometer contrast. Our results highlight the importance of creating and employing nearly pure entangled states for improving atomic clocks.
Many-body entangled states allow precision measurement beyond the standard quantum limit. Yet they have not been effectively exploited in optical lattice clocks except for proof-of-principle demonstrations. Under the current experimental conditions, taking into account the lattice perturbation, atom-atom interactions, and local oscillator noise, we theoretically evaluate the performance of spin-squeezing-based shallow-lattice Yb optical clocks. The numerical simulation shows that the stability of differential frequency comparison between two Yb ensembles in squeezed spin states potentially accesses the ${10}^{\ensuremath{-}19}$ level at the averaging time of 1 s. The resultant Wineland parameter may be as low as ${\ensuremath{\xi}}_{\text{W}}^{2}=0.027$, corresponding to a reduction of averaging time by a factor of 37, and is limited by the collision-induced degradation of spin squeezing. The metrological gain provided by spin squeezing opens up new opportunities for precision measurement and fundamental physics.
Optical atomic clocks have been rapidly developing in recent decades, resulting in major improvements in both precision and accuracy. As a result, they have become instrumental in multiple areas of applied and fundamental research. Despite all atomic frequency references having more than two energy-levels, the commonly used model for evaluating their ultimate limits assumes a two-level atom. This leads to frequency interrogation protocols and theoretical stability bounds that are suboptimal for a true multi-level atom. The most fundamental stability bound assumes two noise sources - quantum projection noise and spontaneous decay from the excited state. In this work, we analyze a model that includes these noise types and is generalized beyond the two-level assumption, where spontaneous decay can branch to more than a single ground state. This model allows for detection and exclusion of atomic frequency interrogations in which the atom decayed, leading to a frequency stability improvement of up to ≈4.5 dB\approx 4.5 \text{ dB}≈4.5 dB compared with the two-level model. Furthermore, we identify an even greater stability enhancement of ≈5.4 dB\approx 5.4 \text{ dB}≈5.4 dB for frequency comparisons between atoms in an odd parity Bell state. These enhancements are particularly relevant for the numerous trapped-ion optical clock species that operate close to lifetime-limited stability. We calculate new stability limits for those cases and provide a detailed experimental protocol for frequency interrogation with an 27Al+^{27}\text{Al}^{+}27Al+ optical ion clock.