Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1910.04202 · Advanced Quantum Technologies

Phase‐Modulated Interferometry, Spectroscopy, and Refractometry using Entangled Photon Pairs

Jonathan Lavoie, Tiemo S. Landes, Amr Tamimi, Brian J. Smith, Andrew H. Marcus, Michael G. Raymer

Published Jan 22, 2020• 23 citations
arXivHTMLPDF

Abstract

Abstract The authors demonstrate a form of two‐photon‐counting interferometry by measuring the coincidence counts between single‐photon‐counting detectors at an output port of a Mach–Zehnder Interferometer (MZI) following injection of broad‐band time‐frequency‐entangled photon pairs (EPP) generated from collinear spontaneous parametric down conversion into a single input port. Spectroscopy and refractometry are performed on a sample inserted in one internal path of the MZI by scanning the other path in length, which acquires phase and amplitude information about the sample's linear response. Phase modulation and lock‐in detection are introduced to increase detection signal‐to‐noise ratio and implement a “down‐sampling” technique for scanning the interferometer delay, which reduces the sampling requirements needed to reproduce fully the temporal interference pattern. The phase‐modulation technique also allows the contributions of various quantum‐state pathways leading to the final detection outcomes to be extracted individually. Feynman diagrams frequently used in the context of molecular spectroscopy are used to describe the interferences resulting from the coherence properties of time‐frequency EPPs passing through the MZI. These results are an important step toward the implementation of a proposed method for molecular spectroscopy—quantum‐light‐enhanced 2D spectroscopy.

DOI
10.1002/qute.201900114

Related papers

Phase-Modulated Two-Photon-Counting Interferometry

Michael G. Raymer, Jonathan Lavoie, Tiemo S. Landes +3 more

We introduce optical lock-in detection in coincidence photon counting to enhance the extraction of information in “quantum-light spectroscopy”, based on using time-frequency entangled photon pairs to probe a molecular sample. The sample is placed inside a Mach-Zehnder interferometer, into which photons are injected and detected in coincidence at the interferometer output. Clear signatures of two-photon interference (both ‘Hong-Ou-Mandel’ and ‘N00N’) are observed and separated into distinct information channels. In addition to achieving an increased signal-to-noise ratio (SNR) at low count rates, the experiment uses a “down-sampling” technique that increases the efficiency of data collection by an order of magnitude.

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting•Jan 1, 2019•0 citations

Interferometric two-photon-absorption spectroscopy with three entangled photons

Lyuzhou Ye, Shaul Mukamel

We propose an interferometric pump-probe technique that employs three entangled photons generated by cascaded spontaneous parametric downconversion. A Mach–Zehnder interferometer made of two three-port waveguide arrays is inserted in the optical path. Two independent phases introduced to manipulate the entangled photon state serve as control parameters and can selectively excite matter pathways. Compared to two-photon-absorption of an entangled photon-pair, the three-photon signals are significantly enhanced by frequency-dispersed photon-counting detection.

Applied Physics Letters•Apr 27, 2020•10 citations

Interaction‐Free Quantum Spectroscopy

Yu Chen, Yujie Cai, Xing-Tong Li +3 more

Interaction‐free measurement (IFM)‐based single‐photon interference is developed as a powerful platform for revealing object information in quantum metrology, where the presence of a sample is identified without photon “touching” in an interferometer. Herein, a method of obtaining the spectroscopic properties with interaction‐free quantum spectroscopy (IFQS) based on the spectrum‐correlated photon pairs by the spontaneous parametric down‐conversion (SPDC) is proposed and implemented. Infrared signal photons around 1557 nm from the SPDC pairs are sent to a Mach–Zehnder interferometer (MZI), which contains a semitransparent sample in one of the arms. The transmission spectrum of the sample is characterized by recording the coincidence detection of the spectrum‐correlated near‐infrared heralding photons around 808 nm from the SPDC. The IFQS can not only distinguish the existence of the sample but also recognize the sample by its transmission spectrum without interaction. The approach unlocks the potential to facilitate the applications of correlation‐based quantum spectroscopy and reduce the power‐induced optical damage of fragile materials.

Advanced Photonics Research•May 6, 2021•10 citations

Investigations of Molecular Optical Properties Using Quantum Light and Hong–Ou–Mandel Interferometry

Audrey V. Eshun, Bing Gu, Oleg P. Varnavski +4 more

Entangled photon pairs have been used for molecular spectroscopy in the form of entangled two-photon absorption and in quantum interferometry for precise measurements of light source properties and time delays. We present an experiment that combines molecular spectroscopy and quantum interferometry by utilizing the correlations of entangled photons in a Hong-Ou-Mandel (HOM) interferometer to study molecular properties. We find that the HOM signal is sensitive to the presence of a resonant organic sample placed in one arm of the interferometer, and the resulting signal contains information pertaining to the light-matter interaction. We can extract the dephasing time of the coherent response induced by the excitation on a femtosecond time scale. A dephasing time of 102 fs is obtained, which is relatively short compared to times found with similar methods and considering line width broadening and the instrument entanglement time As the measurement is done with coincidence counts as opposed to simply intensity, it is unaffected by even-order dispersion effects, and because interactions with the molecular state affect the photon correlation, the observed measurement contains only these effects and no other classical losses. The experiments are accompanied by theory that predicts the observed temporal shift and captures the entangled photon joint spectral amplitude and the molecule's transmission in the coincidence counting rate. Thus, we present a proof-of-concept experimental method based of entangled photon interferometry that can be used to characterize optical properties in organic molecules and can in the future be expanded on for more complex spectroscopic studies of nonlinear optical properties.

Journal of the American Chemical Society•Jun 14, 2021•46 citations

Two-Photon Interference Experiment in a Mach-Zehnder Interferometer

Taesoo Kim, Heonoh Kim, Jeong-Hoon Ko +1 more

A two-photon interference experiment is presented in which an entangled pair of photons generated from a parametric down-conversion was incident on two input ports of a Mach-Zehnder interferometer. The experiment was carried out using two photon coincidence detection with two detectors at the two output ports of the interferometer. The measured coincidence counts exhibit an interference effect with visibility of 0.75 at simultaneous inputs and 0.38 at inputs with different arrival times according to the degree of photon number entanglement.

Journal of the Optical Society of Korea•Jun 1, 2003•11 citations

Two-photon interference in a standard Mach-Zehnder interferometer

Yanhua H. Shih, Alexander V. Sergienko, Morton H. Rubin +2 more

A pair of light quanta with different colors (155.9-nm difference in center wavelength) generated from parametric down-conversion was injected collinearly into one input port of a Mach-Zehnder interferometer. Coincidence interference behavior was studied over a wide range of optical path differences of the interferometer. A measurement of 75% interference visibility with oscillation of the pump frequency for a large optical path difference of the interferometer (43 cm) is the signature of a quantum two-photon entangled state, which reflects both particle and wave nature of the light quanta in one experiment.

Physical Review A•May 1, 1994•39 citations
Abstract The authors demonstrate a form of two‐photon‐counting interferometry by measuring the coincidence counts between single‐photon‐counting detectors at an output port of a Mach–Zehnder Interferometer (MZI) following injection of broad‐band time‐frequency‐entangled photon pairs (EPP) generated from collinear spontaneous parametric down conversion into a single input port. Spectroscopy and refractometry are performed on a sample inserted in one internal path of the MZI by scanning the other path in length, which acquires phase and amplitude information about the sample's linear response. Phase modulation and lock‐in detection are introduced to increase detection signal‐to‐noise ratio and implement a “down‐sampling” technique for scanning the interferometer delay, which reduces the sampling requirements needed to reproduce fully the temporal interference pattern. The phase‐modulation technique also allows the contributions of various quantum‐state pathways leading to the final detection outcomes to be extracted individually. Feynman diagrams frequently used in the context of molecular spectroscopy are used to describe the interferences resulting from the coherence properties of time‐frequency EPPs passing through the MZI. These results are an important step toward the implementation of a proposed method for molecular spectroscopy—quantum‐light‐enhanced 2D spectroscopy.
We introduce optical lock-in detection in coincidence photon counting to enhance the extraction of information in “quantum-light spectroscopy”, based on using time-frequency entangled photon pairs to probe a molecular sample. The sample is placed inside a Mach-Zehnder interferometer, into which photons are injected and detected in coincidence at the interferometer output. Clear signatures of two-photon interference (both ‘Hong-Ou-Mandel’ and ‘N00N’) are observed and separated into distinct information channels. In addition to achieving an increased signal-to-noise ratio (SNR) at low count rates, the experiment uses a “down-sampling” technique that increases the efficiency of data collection by an order of magnitude.
We propose an interferometric pump-probe technique that employs three entangled photons generated by cascaded spontaneous parametric downconversion. A Mach–Zehnder interferometer made of two three-port waveguide arrays is inserted in the optical path. Two independent phases introduced to manipulate the entangled photon state serve as control parameters and can selectively excite matter pathways. Compared to two-photon-absorption of an entangled photon-pair, the three-photon signals are significantly enhanced by frequency-dispersed photon-counting detection.
Interaction‐free measurement (IFM)‐based single‐photon interference is developed as a powerful platform for revealing object information in quantum metrology, where the presence of a sample is identified without photon “touching” in an interferometer. Herein, a method of obtaining the spectroscopic properties with interaction‐free quantum spectroscopy (IFQS) based on the spectrum‐correlated photon pairs by the spontaneous parametric down‐conversion (SPDC) is proposed and implemented. Infrared signal photons around 1557 nm from the SPDC pairs are sent to a Mach–Zehnder interferometer (MZI), which contains a semitransparent sample in one of the arms. The transmission spectrum of the sample is characterized by recording the coincidence detection of the spectrum‐correlated near‐infrared heralding photons around 808 nm from the SPDC. The IFQS can not only distinguish the existence of the sample but also recognize the sample by its transmission spectrum without interaction. The approach unlocks the potential to facilitate the applications of correlation‐based quantum spectroscopy and reduce the power‐induced optical damage of fragile materials.
Entangled photon pairs have been used for molecular spectroscopy in the form of entangled two-photon absorption and in quantum interferometry for precise measurements of light source properties and time delays. We present an experiment that combines molecular spectroscopy and quantum interferometry by utilizing the correlations of entangled photons in a Hong-Ou-Mandel (HOM) interferometer to study molecular properties. We find that the HOM signal is sensitive to the presence of a resonant organic sample placed in one arm of the interferometer, and the resulting signal contains information pertaining to the light-matter interaction. We can extract the dephasing time of the coherent response induced by the excitation on a femtosecond time scale. A dephasing time of 102 fs is obtained, which is relatively short compared to times found with similar methods and considering line width broadening and the instrument entanglement time As the measurement is done with coincidence counts as opposed to simply intensity, it is unaffected by even-order dispersion effects, and because interactions with the molecular state affect the photon correlation, the observed measurement contains only these effects and no other classical losses. The experiments are accompanied by theory that predicts the observed temporal shift and captures the entangled photon joint spectral amplitude and the molecule's transmission in the coincidence counting rate. Thus, we present a proof-of-concept experimental method based of entangled photon interferometry that can be used to characterize optical properties in organic molecules and can in the future be expanded on for more complex spectroscopic studies of nonlinear optical properties.
A two-photon interference experiment is presented in which an entangled pair of photons generated from a parametric down-conversion was incident on two input ports of a Mach-Zehnder interferometer. The experiment was carried out using two photon coincidence detection with two detectors at the two output ports of the interferometer. The measured coincidence counts exhibit an interference effect with visibility of 0.75 at simultaneous inputs and 0.38 at inputs with different arrival times according to the degree of photon number entanglement.
A pair of light quanta with different colors (155.9-nm difference in center wavelength) generated from parametric down-conversion was injected collinearly into one input port of a Mach-Zehnder interferometer. Coincidence interference behavior was studied over a wide range of optical path differences of the interferometer. A measurement of 75% interference visibility with oscillation of the pump frequency for a large optical path difference of the interferometer (43 cm) is the signature of a quantum two-photon entangled state, which reflects both particle and wave nature of the light quanta in one experiment.