arXiv:1908.06898 · Physical Review Applied

Dynamic Characterization of an Alkali-Ion Battery as a Source for Laser-Cooled Atoms

J. P. McGilligan, Kaitlin Moore, S. Kang, Russell P. Mott, Allison V. Mis, Christopher S. Roper, Elizabeth A. Donley, John E. Kitching

Published Apr 14, 2020• 18 citations
arXivHTMLPDF

Abstract

We investigate a solid-state reversible alkali-ion battery (AIB) capable of regulating the density of alkali atoms in a vacuum system used for the production of laser-cooled atoms. The cold-atom sample can be used with in-vacuum chronoamperometry as a diagnostic for the voltage-controlled electrochemical reaction that sources or sinks alkali atoms into the vapor. In a combined reaction-diffusion-limited regime, we show that the number of laser-cooled atoms in a magneto-optical trap can be increased both by initially loading the AIB from the vapor for longer and by using higher voltages across the AIB when atoms are subsequently sourced back into the vapor. The time constants associated with the change in atom number in response to a change in AIB voltage are in the range of 0.5--40 s. The AIB alkali reservoir is demonstrated to survive oxidization during atmospheric exposure, simplifying reservoir loading prior to vacuum implementation as a replacement for traditional resistively heated dispensers. The AIB capabilities may provide an improved atom-number stability in next-generation atomic clocks and sensors, while also facilitating fast loading and increased interrogation times.

DOI
10.1103/physrevapplied.13.044038

Related papers

A low-power reversible alkali atom source

Songbai Kang, Russell P. Mott, Kevin A. Gilmore +5 more

An electrically controllable, solid-state, reversible device for sourcing and sinking alkali vapor is presented. When placed inside an alkali vapor cell, both an increase and decrease in the rubidium vapor density by a factor of two are demonstrated through laser absorption spectroscopy on 10–15 s time scales. The device requires low voltage (5 V), low power (<3.4 mW peak power), and low energy (<10.7 mJ per 10 s pulse). The absence of oxygen emission during operation is shown through residual gas analysis, indicating that Rb is not lost through chemical reaction but rather by ion transport through the designed channel. This device is of interest for atomic physics experiments and, in particular, for portable cold-atom systems where dynamic control of alkali vapor density can enable advances in science and technology.

arXiv:1706.06137•Applied Physics Letters•Jun 12, 2017•22 citations

Magneto-optic trap using a reversible, solid-state alkali-metal source

S. Kang, K. R. Moore, J. P. McGilligan +5 more

We demonstrate a novel way to form and deplete a vapor-cell magneto-optic trap (MOT) using a reversible, solid-state alkali-metal source via an applied polarized voltage. Using ∼100 mW of electrical power, a trapped-atom number of 5×106 has been achieved, starting from near zero and the timescales of the MOT formation and depletion of ∼1 s. This fast, reversible, and low-power alkali-atom source is desirable in both tabletop and portable cold-atom systems. The core technology of this device should translate readily to other alkali and alkaline-earth elements that could find a wide range of uses in cold-atom systems and instruments.

arXiv:1901.09186•Optics Letters•Jun 5, 2019•22 citations

Collimated, single-pass atom source from a pulsed alkali metal dispenser for laser-cooling experiments

Kevin L. Moore, Thomas Purdy, Kater W. Murch +3 more

We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.

arXiv:physics/0409011•Review of Scientific Instruments•Jan 7, 2005•23 citations

Characterization of alkali metal dispensers and non-evaporable getter pumps in ultrahigh vacuum systems for cold atomic sensors

David R. Scherer, David B. Fenner, Joel M. Hensley

A glass ultrahigh vacuum chamber with rubidium alkali metal dispensers and nonevaporable getter pumps has been developed and used to create a cold atomic sample in a chamber that operates with only passive vacuum pumps. The ion-mass spectrum of evaporated gases from the alkali metal dispenser has been recorded as a function of dispenser current. The efficacy of the nonevaporable getter pumps in promoting and maintaining vacuum has been characterized by observation of the Rb vapor optical absorption on the D2 transition at 780 nm and vacuum chamber pressure rate of rise tests. The authors have demonstrated a sample of laser-cooled Rb atoms in this chamber when isolated and operating without active vacuum pumps.

arXiv:1203.1202•Journal of Vacuum Science & Technology A Vacuum Surfaces and Films•Oct 9, 2012•32 citations

Progress on a Miniature Cold-Atom Frequency Standard

David R. Scherer, Robert Lutwak, Mark J. Mescher +8 more

Atomic clocks play a crucial role in timekeeping, communications, and navigation systems. Recent efforts enabled by heterogeneous MEMS integration have led to the commercial introduction of Chip-Scale Atomic Clocks (CSAC) with a volume of 16 cm3, power consumption of 120 mW, and instability (Allan Deviation) of σ(τ = 1 sec) < 2e-10. In order to reduce the temperature sensitivity of next-generation CSACs for timing applications, the interaction of atoms with the environment must be minimized, which can be accomplished in an architecture based on trapped, laser-cooled atoms. In this paper, we present results describing the development of a miniature cold-atom apparatus for operation as a frequency standard. Our architecture is based on laser-cooling a sample of neutral atoms in a Magneto-Optical Trap (MOT) using a conical retro-reflector in a miniature vacuum chamber. Trapping the atoms in vacuum and performing microwave interrogation in the dark reduces the temperature sensitivity compared to vapor-cell CSACs. We present details of the component development associated with the laser systems, opto-electronics, and vacuum package for miniature cold-atom technology. Finally, we conclude by characterizing the optimum alkali background pressure for such a cold-atom frequency standard.

arXiv:1411.5006•Nov 18, 2014•16 citations

Note: A 3D-printed alkali metal dispenser

Eric B. Norrgard, D. S. Barker, J. A. Fedchak +3 more

We demonstrate and characterize a source of Li atoms made from direct metal laser sintered titanium. The source’s outgassing rate is measured to be 5(2) × 10−7 Pa L s−1 at a temperature T = 330 °C, which optimizes the number of atoms loaded into a magneto-optical trap. The source loads ≈107 7Li atoms in the trap in ≈1 s. The loaded source weighs 700 mg and is suitable for a number of deployable sensors based on cold atoms.

arXiv:1801.09612•Review of Scientific Instruments•May 1, 2018•18 citations
We investigate a solid-state reversible alkali-ion battery (AIB) capable of regulating the density of alkali atoms in a vacuum system used for the production of laser-cooled atoms. The cold-atom sample can be used with in-vacuum chronoamperometry as a diagnostic for the voltage-controlled electrochemical reaction that sources or sinks alkali atoms into the vapor. In a combined reaction-diffusion-limited regime, we show that the number of laser-cooled atoms in a magneto-optical trap can be increased both by initially loading the AIB from the vapor for longer and by using higher voltages across the AIB when atoms are subsequently sourced back into the vapor. The time constants associated with the change in atom number in response to a change in AIB voltage are in the range of 0.5--40 s. The AIB alkali reservoir is demonstrated to survive oxidization during atmospheric exposure, simplifying reservoir loading prior to vacuum implementation as a replacement for traditional resistively heated dispensers. The AIB capabilities may provide an improved atom-number stability in next-generation atomic clocks and sensors, while also facilitating fast loading and increased interrogation times.
An electrically controllable, solid-state, reversible device for sourcing and sinking alkali vapor is presented. When placed inside an alkali vapor cell, both an increase and decrease in the rubidium vapor density by a factor of two are demonstrated through laser absorption spectroscopy on 10–15 s time scales. The device requires low voltage (5 V), low power (<3.4 mW peak power), and low energy (<10.7 mJ per 10 s pulse). The absence of oxygen emission during operation is shown through residual gas analysis, indicating that Rb is not lost through chemical reaction but rather by ion transport through the designed channel. This device is of interest for atomic physics experiments and, in particular, for portable cold-atom systems where dynamic control of alkali vapor density can enable advances in science and technology.
We demonstrate a novel way to form and deplete a vapor-cell magneto-optic trap (MOT) using a reversible, solid-state alkali-metal source via an applied polarized voltage. Using ∼100 mW of electrical power, a trapped-atom number of 5×106 has been achieved, starting from near zero and the timescales of the MOT formation and depletion of ∼1 s. This fast, reversible, and low-power alkali-atom source is desirable in both tabletop and portable cold-atom systems. The core technology of this device should translate readily to other alkali and alkaline-earth elements that could find a wide range of uses in cold-atom systems and instruments.
We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.
A glass ultrahigh vacuum chamber with rubidium alkali metal dispensers and nonevaporable getter pumps has been developed and used to create a cold atomic sample in a chamber that operates with only passive vacuum pumps. The ion-mass spectrum of evaporated gases from the alkali metal dispenser has been recorded as a function of dispenser current. The efficacy of the nonevaporable getter pumps in promoting and maintaining vacuum has been characterized by observation of the Rb vapor optical absorption on the D2 transition at 780 nm and vacuum chamber pressure rate of rise tests. The authors have demonstrated a sample of laser-cooled Rb atoms in this chamber when isolated and operating without active vacuum pumps.
Atomic clocks play a crucial role in timekeeping, communications, and navigation systems. Recent efforts enabled by heterogeneous MEMS integration have led to the commercial introduction of Chip-Scale Atomic Clocks (CSAC) with a volume of 16 cm3, power consumption of 120 mW, and instability (Allan Deviation) of σ(τ = 1 sec) < 2e-10. In order to reduce the temperature sensitivity of next-generation CSACs for timing applications, the interaction of atoms with the environment must be minimized, which can be accomplished in an architecture based on trapped, laser-cooled atoms. In this paper, we present results describing the development of a miniature cold-atom apparatus for operation as a frequency standard. Our architecture is based on laser-cooling a sample of neutral atoms in a Magneto-Optical Trap (MOT) using a conical retro-reflector in a miniature vacuum chamber. Trapping the atoms in vacuum and performing microwave interrogation in the dark reduces the temperature sensitivity compared to vapor-cell CSACs. We present details of the component development associated with the laser systems, opto-electronics, and vacuum package for miniature cold-atom technology. Finally, we conclude by characterizing the optimum alkali background pressure for such a cold-atom frequency standard.