Imaging in quantum optics is usually formulated in the languages of quantum mechanics and Fourier optics. While relatively advanced fields, notions such as different reference frames and the degradation of entanglement due to acceleration are not usually featured. Here we propose the idea of using so-called Unruh-DeWitt (UDW) detectors to model the imaging process in quantum optics. In particular, we first present a quantum field theory version of a state describing spontaneous parametric down-conversion, one of the principal processes employed to create entangled photons in the laboratory. This state, coupled to UDW detectors, is used to investigate a single-pixel ghost image under both inertial and noninertial settings, and a two-pixel image under inertial conditions. The reconstructed images obtained for various possible inputs can be distinguished better than a pure guess, hence the formalism can be used to describe imaging between noninertial frames. We briefly consider the origin of the correlations between the UDW detectors, which do not appear to arise from the usual notion of entanglement. Finally, we find that the contrast between the possible outcomes in the single-pixel case follows a curious coupling time dependent behavior.
Imaging in quantum optics is usually formulated in the languages of quantum mechanics and Fourier optics. While relatively advanced fields, notions such as different reference frames and the degradation of entanglement due to acceleration are not usually featured. Here we propose the idea of using so-called Unruh-DeWitt (UDW) detectors to model the imaging process in quantum optics. In particular, we first present a quantum field theory version of a state describing spontaneous parametric down-conversion, one of the principal processes employed to create entangled photons in the laboratory. This state, coupled to UDW detectors, is used to investigate a single-pixel ghost image under both inertial and noninertial settings, and a two-pixel image under inertial conditions. The reconstructed images obtained for various possible inputs can be distinguished better than a pure guess, hence the formalism can be used to describe imaging between noninertial frames. We briefly consider the origin of the correlations between the UDW detectors, which do not appear to arise from the usual notion of entanglement. Finally, we find that the contrast between the possible outcomes in the single-pixel case follows a curious coupling time dependent behavior.
Based on our results for the detector-field system in Gaussian states, I am addressing the following issues about the quantum dynamics of atoms or detectors moving in a relativistic quantum field: First, the dynamics of the detectors as an open quantum quantum system, hence the entanglement creation and sudden death processes between the detectors, are non-Markovian in general. Second, the excitations of the accelerated detectors in the Unruh effect depend only on the kinematics of the detectors. The event horizon for the detector is not essential in this effect, and the particle notion of the quantum field is not needed here. Third, entanglement dynamics of the detectors are independent of time-slicing scheme. Local projective measurements on point-like detectors are also consistent in different time-slicing schemes even in the presence of relativistic quantum fields.
Correlated-photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated-photon ghost-imaging experiments have scanned a single-pixel detector through the field of view to obtain the spatial information. However, scanning leads to a poor sampling efficiency, which scales inversely with the number of pixels, N, in the image. In this work we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far-field of the photon pair source, taking advantage of the EPR-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.
Correlated photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments, two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated photon ghost imaging experiments have scanned a single-pixel detector through the field of view to obtain spatial information. However, scanning leads to poor sampling efficiency, which scales inversely with the number of pixels, N , in the image. In this work, we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far field of the photon pair source, taking advantage of the Einstein–Podolsky–Rosen-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.
We present a quantum-optical platform for simulating relativistic detector-field interactions using entangled nonlinear biphoton sources (ENBSs), realized through phase-controlled single-photon frequency-comb (SPFC) sources. By mapping the dynamical evolution of this system onto the Unruh-DeWitt (UDW) detector model, we show that signal-mode excitations emulate detector transitions driven by vacuum fluctuations, while coherently seeded idler modes act as an effective quantum field. This correspondence enables tabletop exploration of Unruh-like excitation, coherence harvesting, and field-induced entanglement. We derive the effective interaction Hamiltonian and Lindblad master equation for two coherently seeded ENBS units and obtain analytical solutions for the signal photon number Nsig(t) and second-order correlation function g(2)(0;t). Numerical simulations confirm that phase-dependent biphoton dynamics reproduce UDW-type behavior, including tunable excitation and quantum correlations. The output signal state exhibits controllable fidelity, interference visibility, and entanglement entropy as functions of the seeding phase and amplitude. These results establish ENBSs as experimentally accessible quantum simulators of relativistic field phenomena, providing a photonic testbed for analog gravitational effects, vacuum fluctuations, and spacetime-induced coherence-all within reach of current nonlinear-optics technology.
Quantum effects in non-inertial frames and curved space-time have been studied for decades. One of the most intriguing discoveries is the existence of virtual particles in the quantum vacuum. One example in which such particles can be observed is through the Unruh effect, which predicts that a uniformly accelerated observer would see a thermal bath of (virtual) particles in the quantum vacuum. Initial doubts on the existence of these virtual particles were allayed by the Unruh De-Witt (UDW) detector, which promoted these virtual particles to real excitations of the detector. Ever since, semiclassical approaches to relativistic quantum field theory (QFT) in flat and curved space-time have been predominantly analysed through a two-level Unruh De-Witt detector utilizing perturbation theory. It is noted, however, that the change of relativistic frame preserves Gaussian properties (e.g. Gaussian distribution of the Wigner function) of the system. In this thesis, we specifically explore the effects of relativistic (non-inertial) reference frames on QFT by considering relativistic QFT in flat-space time. These systems are analysed from the perspective of Gaussian quantum information, via homodyne detection and UDW detectors with a harmonic oscillator degree of freedom.Our project starts by reviewing and developing bipartite/multi-partite entanglement measures (specifically, entanglement of formation), in the hope that we can utilize these measures to understand the entanglement properties of the quantum vacuum. In general, these measure have infinite degrees of freedom and are incomputable. In this project the multi-partite entanglement measure is applied to the Gaussian regime, which reduces the number of degrees of freedom to a finite one, hence making it a computable measure.In our next project, we attempt to understand how relativistic reference frames affect the communication between different observers. To obtain an intuition of its effect, a passive (time-delay) signal sent from a uniformly accelerated observer to a stationary observer was analysed. When we naively implemented the self-homodyne detection scheme, the signal appeared noisy. This effect was referred to as apparent decoherence, and its effect could be traced back to our naive assumption that all of the signal’s information would be stored in the time-delayed mode; the vacuum entanglement that pre-existed before the (time-delay) signal was created must be accounted for. We follow by analysing the effects that emerge due to communication between different relativistic reference frames. We then develop a communication technique referred to as ideal-homodyne which is a homodyne detection scheme robust to these effects. We used this detection scheme to analyse the correlation/entanglement properties of an accelerated signal (created via accelerated mirror, squeezer and phase shifter) sent to an inertial observer.In our last project, we utilize the knowledge that was gained through the prior projects to analyse (subcycle) electro-optic sampling. In the literature, there were doubts as to whether electro-optic sampling were truly detecting virtual particles in the quantum vacuum, or particle excitations that were created as a by-product of the detection mechanism. We were able to pin-point some similarities between electro-optic sampling and subcycle probe via the UDW detector. The regime in which the electro-optic sampling directly maps virtual particles from the vacuum into real excitations of the probe field was identified by establishing an equivalence to the UDW detector in certain parameter regimes.
The process of image recording is arguably one of the most prevalent technology in modern society and continues to inspire vast swathes of research due to its widespread applications spanning military, medical and consumer spheres. The danger present in a field so broad is that separate niches of research can become isolated with critical advancements struggling to traverse the gulfs between. Unifying the field is the omnipresent drive to acquire an ever increasing quality of images at the lowest possible cost, a goal which warrants continual fundamental research. Quantum entanglement exhibits many intriguing characteristics which make it a suitable tool for such fundamental investigations. The process of spontaneous parametric down- conversion has offered a yet unbeaten strength of photon correlations with the quantum nature of their production providing a reliable and controllable source of single-photons. Arising from these attributes is the technique known as ghost imaging. Though now known to be classically possible, the strength of entanglement generated correlations is yet to be surpassed. This thesis implemented this technique in tandem with the cutting edge detector technology in order to probe the fundamentals of image formation. This form of imaging allowed us to subject an object to a known number of photons whilst acquiring structural information from spatially separate, correlated photons which never interact with the object. The strength of the produced correlations allow us to acquire low background, high resolution images with far less light than traditional techniques and affords many novel benefits. The possibility of incorporating this technique with pre-existent regimes allowed me to draw from advancements made across the landscape of imaging research. Although referred to as “quantum ghost imaging” throughout this work, it should be noted that the intrinsic quantum nature of the correlations was not directly relied upon but provided an ideal source of strongly correlated photons. In order to determine the limits of a traditional imaging system this thesis first sought to answer the question: “can an image of an object be reconstructed from fewer photons than ii pixels in the image?” In chapter 3 I approached this from the perspective of compression, which minimises redundant information within a signal. This lead to the development of an imaging regime capable of imaging with far fewer photons than pixels in the image. By employing assumptions about the sparsity of natural images I was able to reconstruct an image of a biological sample containing an average of less than one photon per image pixel. Having reduced the number of photons necessary to form an image I then considered alternative methods for reducing the optical energy impinging on a sample. I sought to answer the question: “can non-degenerate ghost imaging reduce the optical energy impinged upon an object during imaging”. The photons produced in SPDC need not be of similar wavelengths, however may be chosen far from degeneracy, i.e. non-degenerate. In Chapter 4 I presented a ghost imaging system which illuminated the object with infrared light whilst recording the structural information via entangled visible photons. This allowed for objects opaque to visible light to be imaged in high quality without the need for a spatially resolving infrared detector, the state of the art of which lags behind their silicon based visible counterparts. I presented the systems capabilities by imaging objects which were etched into a gold substrate layered on to silicon, both of which are opaque to visible light. Not only did a reduction in energy deposition arise from the lower energy probe wavelength but applying the reconstruction techniques from the previous chapter brought that down to as low as ≈16 nJcm−2s−1. Seeking to expand the repertoire of applications, the low-light capabilities of my ghost imaging were applied to the technique of phase-contrast microscopy in chapter 5. Typically applied to translucent objects, phase-contrast imaging transfers phase information, i.e. the refractive index changed within the object, into an intensity distribution through the use of a phase-filter. In many of these applications the objects tend to be biological in nature, where high optical exposure can result in bleaching or damage. By applying the phase-filter non- locally, i.e. to the photons correlated to those probing the object, I acquired edge-enhanced images of a phase object whilst illuminating with significantly fewer photons than standard phase-contrast techniques. Having displayed the broad applicability of our low-light ghost imaging system, I then sought to determine the optical resolution in chapter 6. The resolution limits of ghost imaging are not clear at first glance owing to the resolutions dependence upon the strength of spatial correlations. As the length over which the spatial correlations are produced can be brought below the standard diffraction limit, it would seem the resolution of the system could be brought similarly low. To clarify this I artificially restricted the number of spatial modes in each of the correlated beams to uncover the physically realisable resolution. I show that although the resolution of a ghost imaging system to be fundamentally determined by the strength of the correlations, this can never be reached due to the inherent limitations of the intervening imaging system.