arXiv:1903.05930 · Light Science & Applications

Quantum expander for gravitational-wave observatories

Mikhail Korobko, Yiqiu Ma, Yanbei Chen, Roman Schnabel

Published Dec 11, 2019• 40 citations
arXivHTMLPDF

Abstract

The quantum uncertainty of laser light limits the sensitivity of gravitational-wave observatories. Over the past 30 years, techniques for squeezing the quantum uncertainty, as well as for enhancing gravitational-wave signals with optical resonators have been invented. Resonators, however, have finite linewidths, and the high signal frequencies that are produced during the highly scientifically interesting ring-down of astrophysical compact-binary mergers still cannot be resolved. Here, we propose a purely optical approach for expanding the detection bandwidth. It uses quantum uncertainty squeezing inside one of the optical resonators, compensating for the finite resonators' linewidths while keeping the low-frequency sensitivity unchanged. This quantum expander is intended to enhance the sensitivity of future gravitational-wave detectors, and we suggest the use of this new tool in other cavity-enhanced metrological experiments.

DOI
10.1038/s41377-019-0230-2

Related papers

Coherent feedback for quantum expander in gravitational wave observatories

N. Boettner, J. D. Bentley, Roman Schnabel +1 more

The observation of gravitational waves from binary neutron star mergers offers insights into properties of extreme nuclear matter. However, their high-frequency signals in the kHz range are often masked by quantum noise of the laser light used. Here, we propose the ``quantum expander with coherent feedback,'' a new detector design that features an additional optical cavity in the detector output and an internal squeeze operation. This approach allows us to boost the sensitivity at high frequencies while at the same time providing a compact and tunable design for signal extraction. It also allows us to tailor the sensitivity of the detector to the specific signal frequency range. We demonstrate that our design can improve the sensitivity of the high-frequency detector concept NEMO, increasing the detection rates by around 14%. Our approach promises a new level of flexibility in designing the detectors aimed at high-frequency signals.

arXiv:2403.03758•Physical review. D/Physical review. D.•Nov 12, 2024•2 citations

Taming the quantum noise : How quantum metrology can expand the reach of gravitational-wave observatories

M. Korobko

The dawn of gravitational-wave astronomy has begun in 2015 with the historic detection of a binary black hole merger. Several more detections followed in the years after. Among them, the detectors observed the inspiral of a neutron star binary. This merger was also observed in a broad spectrum of electromagnetic counterparts. This multi-messenger observation demonstrated that gravitational-wave astronomy is invaluable for understanding the Universe. Current detectors, however, are able to see only a small part of binaries’ inspirals. A typical signal from an inspiral of a binary neutron star appears in the detector at low frequencies a few minutes before the merger. During the inspiral, the frequency of the signal increases, faster for higher frequencies. It quickly passes through the detection band of the observatory. The merger itself and post-merger oscillations often remain inaccessible due to the reduced sensitivity of the detector to high-frequency signals. An increase in the low-frequency sensitivity will allow to detect signals significantly earlier, extracting more information about the binary. This will allow to precisely locate the source on the sky for the follow-up multi-messenger observations. An increase in the high-frequency sensitivity will give a possibility to observe the merger and post-merger signals, gaining insight into the physics of ultra-dense quantum matter. The limitations to the sensitivity arise from quantum nature of light used to sense the displacement of mirrors caused by gravitational waves. At low frequencies, quantum fluctuations in the amplitude of the light field cause random forces on the mirrors, which mask the signal from gravitational waves. At high frequencies, quantum fluctuations in the phase of the light field cause measurement noise on the detectors. The detectors use optical cavities to enhance the signal within the bandwidth of the cavities. At frequencies outside this bandwidth the signal is getting suppressed. Signals from the binary neutron star mergers typically have frequencies outside the detection bandwidth. In this thesis I study the fundamental limitations on the sensitivity of detectors, in the quest of a broadband observatory. I discuss a speedmeter approach to increasing the low-frequency sensitivity, and propose two ways of achieving it: with quantum-entangled light, and in a novel ring cavity topology of the detector, which I test experimentally. I further study the fundamental limits arising from the finite bandwidth of the cavities, and demonstrate experimentally how this limit can be overcome. I propose a concept of quantum expander that allows to increase the detection bandwidth by using quantum correlations, generated directly inside the detector’s cavities. I investigate, how quantum correlations, controlled by internal squeezing, can help to tailor the sensitivity of the detector for the optimal performance at selected frequencies. Finally, I show that, although the benefit from application of squeezed light in metrology is limited by quantum decoherence, its impact on the sensitivity can be reduced by exploiting quantum correlations created with internal squeezing. Quantum nature of light is a nuisance, which prevents us from seeing gravitational waves, but also a powerful tool, if properly applied. Quantum correlations hidden in the noise can be exploited for the benefit of the detectors, as I show in various scenarios throughout the thesis. Quantum noise can be tamed, and not only in gravitational-wave detectors. All cavity-enhanced quantum metrological experiments can use quantum noise and underlying correlations as the resource for tailoring their sensitivity. 2015 begann mit der erstmaligen Beobachtung der Verschmelzung zweier schwarzer Locher das Zeitalter der Gravitationswellenastronomie. In den darauffolgenden Jahren gab es viele weitere Detektionen. Unter anderem wurde das Gravitationswellensignal der Verschmelzung zweier Neutronensterne detektiert. Parallel zur Messung der Gravitationswellen wurde auch das elektromagnetische Spektrum dieses Ereignisses beobachtet. Diese Multi-Messenger Beobachtung hat gezeigt, dass Gravitationswellenastronomie wesentlich fur das Verstandnis des Universums ist. Aktuell kann jedoch nur eine kleine Zahl von astronomischen Ereignissen detektiert werden, denn die Signale sind typischerweise nur wenige Minuten vor der eigentlichen Verschmelzung messbar und haben dann sehr kleine Frequenzen. Solange sich die astronomischen Objekte umkreisen, erhoht sich die Signalfrequenz und zwar mit schneller werdender Rate hin zu hoheren Frequenzen. Auf diese Art und Weise durchlauft das Signal schnell das Detektionsband des Gravitationswellendetektors und die eigentliche Verschmelzung sowie darauffolgende Oszillationssignale konnen nicht beobachtet werden, weil die Sensitivitat der Detektoren bei den dafur notigen hoheren Frequenzen nicht ausreicht. Eine Erhohung der Sensitivitat bei kleinen Frequenzen wurde eine fruhere Detektion von Signalen ermoglichen, sodass mehr Informationen uber die astronomischen Objekte gewonnen werden konnen. Auserdem wurde die Signalquelle am Himmel prazise lokalisierbar, sodass Beobachtungen durch weitere Teleskope fruhzeitig beginnen konnten. Eine hohere Sensitivitat im hochfrequenten Bereich wurde es ermoglichen, auch die eigentliche Verschmelzung zu beobachten sowie Signale nach der Verschmelzung zu messen. Dadurch konnten neue Erkenntnisse zur Physik von ultradichter Quantenmaterie gewonnen werden. Limitiert wird die Sensitivitat, sowohl bei hohen als auch bei niedrigen Frequenzen, durch die Quanteneigenschaften des Laserlichts, welches genutzt wird, um die relativen Positionsanderungen von Spiegeln zu messen. Diese Anderungen werden durch Gravitationswellen hervorgerufen. Bei kleinen Frequenzen sorgt die Amplitudenunscharfe des Lichts fur Schwankungen des auf die Spiegel wirkenden Strahlungsdrucks, wodurch das Gravitationswellensignal uberdeckt wird. Bei hohen Frequenzen koppelt durch die Phasenunscharfe des Lichts Rauschen in die Detektoren ein. In die Detektoren sind auserdem optische Resonatoren integriert, welche das Messsignal innerhalb der Resonatorbandbreite verstarken. Signale auserhalb der Bandbreite werden unterdruckt. Gravitationswellensignale von sich umkreisenden Neutronensternen haben in der Regel Frequenzen auserhalb dieser Detektionsbandbreite. In dieser Arbeit befasse ich mich mit der Limitierung der Sensitivitat der Detektoren und zeige Wege auf, diese zu verbessern. Dafur diskutiere ich einen Detektor, welcher auf einer Geschwindigkeitsmessung basiert und zeige zwei Wege auf, um die Messgenauigkeit zu steigern: Zum einen mit quantenverschranktem Licht und zum anderen mit einem Umlaufresonator, also einer neuartigen Detektortopologie. Auserdem studiere ich die Sensitivitasbeschrankungen, welche durch die Resonatoren zur Signalverstarkung entstehen. Um diese Beschra nkungen zu reduzieren, schlage ich ein neuartiges Konzept vor, bei dem quantenkorreliertes Licht direkt in den Resonatoren erzeugt wird und so die Detektionsbandbreite erhoht. Ich untersuche, wie die durch internes squeezing kontrollierten Quantenkorrelationen dabei helfen konnen, die Empfindlichkeit des Detektors bei ausgewahlten Frequenzen zu optimieren. Dabei zeige ich, das der Einfluss von Dekoharenz auf durch Quetschlicht optimierte Sensitivitat durch die Nutzung von Quantenkorrelationen, die durch internes Squeezing erzeugt werden, reduziert werden kann. Die Quantennatur des Lichts stellt ein fundamentales Limit fur die Sensitivitat der Gravitationswellendetektoren dar und verhindert die Beobachtung schwacher Signale. Sie kann aber auch als nutzliches Werkzeug eingesetzt werden, um durch Quantenkorrelationen schwa chste, im Rauschen versteckte Signale, sichtbar zu machen. Dies zeige ich fur unterschiedliche Szenarien in dieser Arbeit. Nicht nur die Gravitationswellenastronomie kann von diesen Ansatzen profitieren. In allen Resonator gestutzten quantenmetrologischen Experimenten konnen Quantenkorrelationen genutzt werden, um die Messsensitivitat zu verbessern.

•Aug 6, 2020•1 citation

Quantum enhancement of a 4km laser interferometer gravitational-wave detector

S. Chua

The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.

•Jan 1, 2013•1 citation

Advanced quantum techniques for future gravitational-wave detectors

S. L. Danilishin, Farid Ya. Khalili, Haixing Miao

Quantum fluctuation of light limits the sensitivity of advanced laser interferometric gravitational-wave detectors. It is one of the principal obstacles on the way towards the next-generation gravitational-wave observatories. The envisioned significant improvement of the detector sensitivity requires using quantum non-demolition measurement and back-action evasion techniques, which allow us to circumvent the sensitivity limit imposed by the Heisenberg uncertainty principle. In our previous review article (Danilishin and Khalili in Living Rev Relativ 15:5, 2012 ), we laid down the basic principles of quantum measurement theory and provided the framework for analysing the quantum noise of interferometers. The scope of this paper is to review novel techniques for quantum noise suppression proposed in the recent years and put them in the same framework. Our delineation of interferometry schemes and topologies is intended as an aid in the process of selecting the design for the next-generation gravitational-wave observatories.

arXiv:1903.05223•Living Reviews in Relativity•Apr 29, 2019•84 citations

Generation and detection of low-frequency squeezing for gravitational-wave detection

Michael Stefszky

Gravitational-wave astronomy promises a radically new method of investigating the universe, one that does not detect elementary particles, but rather ripples in space-time itself. One might expect that with this radically new method, our understanding of the universe will make an equally giant leap. One of the most promising methods for the eventual detection of gravitational-waves is that of interferometric gravitational-wave detection. The sensitivity of these devices is nothing short of amazing, and their sensitivity continues to improve. The next generation of detectors are expected reach a point where increasing the laser power, previously used to increase the sensitivity, is no longer expected to provide any benefit. One of the most promising options for further increasing the sensitivity, through reduction of the quantum noise, is via the application of "squeezed states of light". Squeezed states of light are light fields for which the noise of some observable has been reduced below the quantum noise limit. These states have been shown for many years to offer increased sensitivity in interferometers and recently in interferometric gravitational-wave detectors. One of the most challenging tasks to make suitable squeezed light sources for these detectors is to produce low-frequency squeezing, corresponding to the detection band of these interferometers. This thesis details the doubly resonant travelling wave bow-tie squeezer as a source of squeezing for interferometric gravitational-wave detection. This squeezer achieves record results of squeezing in the gravitational-wave detection band. For the first time, 10 dB of shot noise suppression at 10Hz is directly observed and above 200Hz, 11.6 dB is observed. The work presented in this thesis provides evidence that further substantiates previous progress indicating that squeezed states of light are now ready for full-time integration into interferometric gravitational-wave detectors. The new cavity design, described in detail throughout this thesis, is shown to outperform previous designs and provide benefits when integrating squeezing into these detectors, in particular, isolation to backscattered light from the interferometer. The noise sources that typically lead to degradation in squeezing measurements are investigated and discussed. Additionally, a modification to the standard locking technique used to control these vacuum squeezed states, coherent locking, is presented and discussed. The modified technique reduces the required number of locking loops and provides a larger beat note from which to derive an error signal for one of the remaining loops. A squeezer using these design philosophies is then constructed and used to inject squeezing into the LIGO gravitational-wave detector. Injection of the squeezed state provides enhancement of the sensitivity of the detector at frequencies around 200Hz and above. The sensitivity seen was equivalent to approximately 2 dB of shot noise reduction. The enhancement is limited by the loss within the interferometer. Injection of the squeezed state did not show any degradation in the sensitivity of the device below 200Hz, indicating for the first time that noise couplings between the interferometer and the squeezer could be sufficiently suppressed at these frequencies even for the most sensitive detectors.

•Jan 1, 2012•1 citation

Squeezed light for gravitational wave astronomy

H. Vahlbruch

During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.

•Jan 1, 2008•12 citations
The quantum uncertainty of laser light limits the sensitivity of gravitational-wave observatories. Over the past 30 years, techniques for squeezing the quantum uncertainty, as well as for enhancing gravitational-wave signals with optical resonators have been invented. Resonators, however, have finite linewidths, and the high signal frequencies that are produced during the highly scientifically interesting ring-down of astrophysical compact-binary mergers still cannot be resolved. Here, we propose a purely optical approach for expanding the detection bandwidth. It uses quantum uncertainty squeezing inside one of the optical resonators, compensating for the finite resonators' linewidths while keeping the low-frequency sensitivity unchanged. This quantum expander is intended to enhance the sensitivity of future gravitational-wave detectors, and we suggest the use of this new tool in other cavity-enhanced metrological experiments.
The observation of gravitational waves from binary neutron star mergers offers insights into properties of extreme nuclear matter. However, their high-frequency signals in the kHz range are often masked by quantum noise of the laser light used. Here, we propose the ``quantum expander with coherent feedback,'' a new detector design that features an additional optical cavity in the detector output and an internal squeeze operation. This approach allows us to boost the sensitivity at high frequencies while at the same time providing a compact and tunable design for signal extraction. It also allows us to tailor the sensitivity of the detector to the specific signal frequency range. We demonstrate that our design can improve the sensitivity of the high-frequency detector concept NEMO, increasing the detection rates by around 14%. Our approach promises a new level of flexibility in designing the detectors aimed at high-frequency signals.
The dawn of gravitational-wave astronomy has begun in 2015 with the historic detection of a binary black hole merger. Several more detections followed in the years after. Among them, the detectors observed the inspiral of a neutron star binary. This merger was also observed in a broad spectrum of electromagnetic counterparts. This multi-messenger observation demonstrated that gravitational-wave astronomy is invaluable for understanding the Universe. Current detectors, however, are able to see only a small part of binaries’ inspirals. A typical signal from an inspiral of a binary neutron star appears in the detector at low frequencies a few minutes before the merger. During the inspiral, the frequency of the signal increases, faster for higher frequencies. It quickly passes through the detection band of the observatory. The merger itself and post-merger oscillations often remain inaccessible due to the reduced sensitivity of the detector to high-frequency signals. An increase in the low-frequency sensitivity will allow to detect signals significantly earlier, extracting more information about the binary. This will allow to precisely locate the source on the sky for the follow-up multi-messenger observations. An increase in the high-frequency sensitivity will give a possibility to observe the merger and post-merger signals, gaining insight into the physics of ultra-dense quantum matter. The limitations to the sensitivity arise from quantum nature of light used to sense the displacement of mirrors caused by gravitational waves. At low frequencies, quantum fluctuations in the amplitude of the light field cause random forces on the mirrors, which mask the signal from gravitational waves. At high frequencies, quantum fluctuations in the phase of the light field cause measurement noise on the detectors. The detectors use optical cavities to enhance the signal within the bandwidth of the cavities. At frequencies outside this bandwidth the signal is getting suppressed. Signals from the binary neutron star mergers typically have frequencies outside the detection bandwidth. In this thesis I study the fundamental limitations on the sensitivity of detectors, in the quest of a broadband observatory. I discuss a speedmeter approach to increasing the low-frequency sensitivity, and propose two ways of achieving it: with quantum-entangled light, and in a novel ring cavity topology of the detector, which I test experimentally. I further study the fundamental limits arising from the finite bandwidth of the cavities, and demonstrate experimentally how this limit can be overcome. I propose a concept of quantum expander that allows to increase the detection bandwidth by using quantum correlations, generated directly inside the detector’s cavities. I investigate, how quantum correlations, controlled by internal squeezing, can help to tailor the sensitivity of the detector for the optimal performance at selected frequencies. Finally, I show that, although the benefit from application of squeezed light in metrology is limited by quantum decoherence, its impact on the sensitivity can be reduced by exploiting quantum correlations created with internal squeezing. Quantum nature of light is a nuisance, which prevents us from seeing gravitational waves, but also a powerful tool, if properly applied. Quantum correlations hidden in the noise can be exploited for the benefit of the detectors, as I show in various scenarios throughout the thesis. Quantum noise can be tamed, and not only in gravitational-wave detectors. All cavity-enhanced quantum metrological experiments can use quantum noise and underlying correlations as the resource for tailoring their sensitivity. 2015 begann mit der erstmaligen Beobachtung der Verschmelzung zweier schwarzer Locher das Zeitalter der Gravitationswellenastronomie. In den darauffolgenden Jahren gab es viele weitere Detektionen. Unter anderem wurde das Gravitationswellensignal der Verschmelzung zweier Neutronensterne detektiert. Parallel zur Messung der Gravitationswellen wurde auch das elektromagnetische Spektrum dieses Ereignisses beobachtet. Diese Multi-Messenger Beobachtung hat gezeigt, dass Gravitationswellenastronomie wesentlich fur das Verstandnis des Universums ist. Aktuell kann jedoch nur eine kleine Zahl von astronomischen Ereignissen detektiert werden, denn die Signale sind typischerweise nur wenige Minuten vor der eigentlichen Verschmelzung messbar und haben dann sehr kleine Frequenzen. Solange sich die astronomischen Objekte umkreisen, erhoht sich die Signalfrequenz und zwar mit schneller werdender Rate hin zu hoheren Frequenzen. Auf diese Art und Weise durchlauft das Signal schnell das Detektionsband des Gravitationswellendetektors und die eigentliche Verschmelzung sowie darauffolgende Oszillationssignale konnen nicht beobachtet werden, weil die Sensitivitat der Detektoren bei den dafur notigen hoheren Frequenzen nicht ausreicht. Eine Erhohung der Sensitivitat bei kleinen Frequenzen wurde eine fruhere Detektion von Signalen ermoglichen, sodass mehr Informationen uber die astronomischen Objekte gewonnen werden konnen. Auserdem wurde die Signalquelle am Himmel prazise lokalisierbar, sodass Beobachtungen durch weitere Teleskope fruhzeitig beginnen konnten. Eine hohere Sensitivitat im hochfrequenten Bereich wurde es ermoglichen, auch die eigentliche Verschmelzung zu beobachten sowie Signale nach der Verschmelzung zu messen. Dadurch konnten neue Erkenntnisse zur Physik von ultradichter Quantenmaterie gewonnen werden. Limitiert wird die Sensitivitat, sowohl bei hohen als auch bei niedrigen Frequenzen, durch die Quanteneigenschaften des Laserlichts, welches genutzt wird, um die relativen Positionsanderungen von Spiegeln zu messen. Diese Anderungen werden durch Gravitationswellen hervorgerufen. Bei kleinen Frequenzen sorgt die Amplitudenunscharfe des Lichts fur Schwankungen des auf die Spiegel wirkenden Strahlungsdrucks, wodurch das Gravitationswellensignal uberdeckt wird. Bei hohen Frequenzen koppelt durch die Phasenunscharfe des Lichts Rauschen in die Detektoren ein. In die Detektoren sind auserdem optische Resonatoren integriert, welche das Messsignal innerhalb der Resonatorbandbreite verstarken. Signale auserhalb der Bandbreite werden unterdruckt. Gravitationswellensignale von sich umkreisenden Neutronensternen haben in der Regel Frequenzen auserhalb dieser Detektionsbandbreite. In dieser Arbeit befasse ich mich mit der Limitierung der Sensitivitat der Detektoren und zeige Wege auf, diese zu verbessern. Dafur diskutiere ich einen Detektor, welcher auf einer Geschwindigkeitsmessung basiert und zeige zwei Wege auf, um die Messgenauigkeit zu steigern: Zum einen mit quantenverschranktem Licht und zum anderen mit einem Umlaufresonator, also einer neuartigen Detektortopologie. Auserdem studiere ich die Sensitivitasbeschrankungen, welche durch die Resonatoren zur Signalverstarkung entstehen. Um diese Beschra nkungen zu reduzieren, schlage ich ein neuartiges Konzept vor, bei dem quantenkorreliertes Licht direkt in den Resonatoren erzeugt wird und so die Detektionsbandbreite erhoht. Ich untersuche, wie die durch internes squeezing kontrollierten Quantenkorrelationen dabei helfen konnen, die Empfindlichkeit des Detektors bei ausgewahlten Frequenzen zu optimieren. Dabei zeige ich, das der Einfluss von Dekoharenz auf durch Quetschlicht optimierte Sensitivitat durch die Nutzung von Quantenkorrelationen, die durch internes Squeezing erzeugt werden, reduziert werden kann. Die Quantennatur des Lichts stellt ein fundamentales Limit fur die Sensitivitat der Gravitationswellendetektoren dar und verhindert die Beobachtung schwacher Signale. Sie kann aber auch als nutzliches Werkzeug eingesetzt werden, um durch Quantenkorrelationen schwa chste, im Rauschen versteckte Signale, sichtbar zu machen. Dies zeige ich fur unterschiedliche Szenarien in dieser Arbeit. Nicht nur die Gravitationswellenastronomie kann von diesen Ansatzen profitieren. In allen Resonator gestutzten quantenmetrologischen Experimenten konnen Quantenkorrelationen genutzt werden, um die Messsensitivitat zu verbessern.
The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.
Quantum fluctuation of light limits the sensitivity of advanced laser interferometric gravitational-wave detectors. It is one of the principal obstacles on the way towards the next-generation gravitational-wave observatories. The envisioned significant improvement of the detector sensitivity requires using quantum non-demolition measurement and back-action evasion techniques, which allow us to circumvent the sensitivity limit imposed by the Heisenberg uncertainty principle. In our previous review article (Danilishin and Khalili in Living Rev Relativ 15:5, 2012 ), we laid down the basic principles of quantum measurement theory and provided the framework for analysing the quantum noise of interferometers. The scope of this paper is to review novel techniques for quantum noise suppression proposed in the recent years and put them in the same framework. Our delineation of interferometry schemes and topologies is intended as an aid in the process of selecting the design for the next-generation gravitational-wave observatories.
Gravitational-wave astronomy promises a radically new method of investigating the universe, one that does not detect elementary particles, but rather ripples in space-time itself. One might expect that with this radically new method, our understanding of the universe will make an equally giant leap. One of the most promising methods for the eventual detection of gravitational-waves is that of interferometric gravitational-wave detection. The sensitivity of these devices is nothing short of amazing, and their sensitivity continues to improve. The next generation of detectors are expected reach a point where increasing the laser power, previously used to increase the sensitivity, is no longer expected to provide any benefit. One of the most promising options for further increasing the sensitivity, through reduction of the quantum noise, is via the application of "squeezed states of light". Squeezed states of light are light fields for which the noise of some observable has been reduced below the quantum noise limit. These states have been shown for many years to offer increased sensitivity in interferometers and recently in interferometric gravitational-wave detectors. One of the most challenging tasks to make suitable squeezed light sources for these detectors is to produce low-frequency squeezing, corresponding to the detection band of these interferometers. This thesis details the doubly resonant travelling wave bow-tie squeezer as a source of squeezing for interferometric gravitational-wave detection. This squeezer achieves record results of squeezing in the gravitational-wave detection band. For the first time, 10 dB of shot noise suppression at 10Hz is directly observed and above 200Hz, 11.6 dB is observed. The work presented in this thesis provides evidence that further substantiates previous progress indicating that squeezed states of light are now ready for full-time integration into interferometric gravitational-wave detectors. The new cavity design, described in detail throughout this thesis, is shown to outperform previous designs and provide benefits when integrating squeezing into these detectors, in particular, isolation to backscattered light from the interferometer. The noise sources that typically lead to degradation in squeezing measurements are investigated and discussed. Additionally, a modification to the standard locking technique used to control these vacuum squeezed states, coherent locking, is presented and discussed. The modified technique reduces the required number of locking loops and provides a larger beat note from which to derive an error signal for one of the remaining loops. A squeezer using these design philosophies is then constructed and used to inject squeezing into the LIGO gravitational-wave detector. Injection of the squeezed state provides enhancement of the sensitivity of the detector at frequencies around 200Hz and above. The sensitivity seen was equivalent to approximately 2 dB of shot noise reduction. The enhancement is limited by the loss within the interferometer. Injection of the squeezed state did not show any degradation in the sensitivity of the device below 200Hz, indicating for the first time that noise couplings between the interferometer and the squeezer could be sufficiently suppressed at these frequencies even for the most sensitive detectors.
During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.