Systematic uncertainty due to background-gas collisions in trapped-ion optical clocks

Aaron M. Hankin, Ethan Clements, Yao Huang, Samuel M. Brewer, Jwo-Sy Chen, C. W. Chou, David B. Hume, David R. Leibrandt

Published Sep 30, 2019• 38 citations
arXivHTMLPDF

Abstract

We describe a framework for calculating the frequency shift and uncertainty of trapped-ion optical atomic clocks caused by background-gas collisions, and apply this framework to an $^{27}\mathrm{Al}^{+}$ clock to enable a total fractional systematic uncertainty below ${10}^{\ensuremath{-}18}$. For this clock, with 38(19) nPa of room-temperature ${\mathrm{H}}_{2}$ background gas, we find that collisional heating generates a non-thermal distribution of motional states with a mean time-dilation shift of order ${10}^{\ensuremath{-}16}$ at the end of a 150 ms probe, which is not detected by sideband thermometry energy measurements. However, the contribution of collisional heating to the spectroscopy signal is highly suppressed and we calculate the BGC shift to be $\ensuremath{-}0.6(2.4)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$, where the shift is due to collisional heating time dilation and the uncertainty is dominated by the worst case $\ifmmode\pm\else\textpm\fi{}\ensuremath{\pi}/2$ bound used for collisional phase shift of the $^{27}\mathrm{Al}^{+}$ superposition state. We experimentally validate the framework and determine the background-gas pressure in situ using measurements of the rate of collisions that cause reordering of mixed-species ion pairs.

DOI
10.1103/physreva.100.033419

Related papers

The collisional frequency shift of a trapped-ion optical clock

Amar C. Vutha, Tom Kirchner, P. Dubé

Summary form only given. As the performance of optical atomic clocks improves steadily, new sources of systematic errors need to be evaluated with increasingly higher accuracy. At present, the collisional frequency shift (CFS), due to interactions with background gas atoms in the environment of the clock ions, is in some cases the next-to-leading source of systematic uncertainty for trapped-ion optical clocks. Existing approaches towards evaluating the CFS have either assumed that only glancing-angle collisions are relevant, or assumed a worst-case scenario for the phase shift imparted to clock state superposition by a collision. The former approach, which was developed for laser-cooled cesium clocks, is not applicable to the deeply trapped atomic ions used in optical clocks, while the latter approach is likely to significantly overestimate the CFS. To address this problem we have developed a framework, based on a non-perturbative quantum channel description of the collision process. Our method leads to a convenient master equation and a compact expression for the CFS. In particular, this framework can be used to estimate the CFS in situations involving many partial waves and large collisional phase shifts, which is the case with thermal background gas atoms scattering off a clock ion. Our method lends itself to practical evaluations of the CFS, by using readily calculated molecular potential curves for the ion-background gas system to extract the collisional phase shifts which lead to the CFS. As an application of this method to a realistic and relevant situation, we have numerically estimated the frequency shift of the 674 nm clock transition in Sr+due to collisions with background helium gas. We find that the CFS is much smaller than the worst-case estimate. In this talk, we describe the theoretical background and motivate the steps that lead to our framework for calculating the CFS. Following this, we present our calculations for the Sr+-He system as an example of the general method, and discuss possible extensions and improvements that will allow us to evaluate the CFS for the Sr+clock at the National Research Council Canada.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•1 citation

Collisional frequency shift of a trapped-ion optical clock

Amar C. Vutha, Tom Kirchner, P. Dubé

Collisions with background gas can perturb the transition frequency of trapped ions in an optical atomic clock. We develop a nonperturbative framework based on a quantum channel description of the scattering process and use it to derive a master equation which leads to a simple analytic expression for the collisional frequency shift. As a demonstration of our method, we calculate the frequency shift of the ${\mathrm{Sr}}^{+}$ optical atomic clock transition due to elastic collisions with helium.

arXiv:1705.10019•Physical Review A•Aug 11, 2017•26 citations

Collisional frequency shifts in Sr + optical clocks

Iosif V. Leibin, Inna S. Kalinina, Amar C. Vutha +1 more

Collisions of atomic ions in optical clocks with background gas molecules result in systematic frequency shifts. We evaluate the frequency shift in ${\mathrm{Sr}}^{+}$ clocks due to collisions with helium atoms and hydrogen molecules, using ab initio spin-orbit-coupled potential energy surfaces together with a master equation for the collisional shift. Our results lead to improved uncertainty estimates for collisional frequency shifts in ${\mathrm{Sr}}^{+}$ optical clocks.

Physical Review A•Sep 17, 2025•2 citations

Improved estimate of the collisional frequency shift in Al + optical clocks

Jack Davis, P. Dubé, Amar C. Vutha

The collisional frequency shift in the leading trapped-ion optical clock is calculated with improved accuracy, using a new method. Modeling the collision between the clock ion and background gas as a quantum channel, the authors develop a master equation that yields a hundred-fold improved estimate of the clock's frequency shift due to background gas collisions.

arXiv:1901.06443•Physical Review Research•Dec 2, 2019•9 citations

Phase shifts and fluctuations from motional, relativistic, and dark-matter effects in ion-trap clocks

Alexander Bott, Fabio Di Pumpo, Enno Giese

Ions possess both center-of-mass motion and internal states, rendering trapped-ion optical clocks susceptible to perturbations of both degrees of freedom, which results in systematic shifts and fluctuations with motional and relativistic origins. We develop a quantum theory that connects these effects to filter functions determined by the employed pulse sequences and show how the interrogation can be tailored to suppress or enhance specific perturbations. Our treatment includes laser frequency noise and motional effects such as recoil and Doppler shifts, micromotion and excess micromotion, as well as state-dependent trap imperfections and accelerations, e.g., caused by Stark shifts. We further account for relativistic effects including time dilation and the mass defect, and show how the same framework can be applied to hypothetical dark-matter signals. By considering ensemble-averaged phases and their variances, we characterize both systematic shifts and fluctuations, while asynchronous operation relative to the Paul-trap drive allows motional fluctuations to average down between runs. Our results provide a unified framework for characterizing and controlling the systematic and statistical contributions that determine the trueness and precision of trapped-ion optical clocks.

quant-pharXiv:2610.27994•Oct 21, 2026•0 citations

Sub-kelvin temperature management in ion traps for optical clocks

T. Nordmann, Alexandre Didier, M. Doležal +3 more

The uncertainty of the ac Stark shift due to thermal radiation represents a major contribution to the systematic uncertainty budget of state-of-the-art optical atomic clocks. In the case of optical clocks based on trapped ions, the thermal behavior of the rf-driven ion trap must be precisely known. This determination is even more difficult when scalable linear ion traps are used. Such traps enable a more advanced control of multiple ions and have become a platform for new applications in quantum metrology, simulation, and computation. Nevertheless, their complex structure makes it more difficult to precisely determine its temperature in operation and thus the related systematic uncertainty. We present here scalable linear ion traps for optical clocks, which exhibit very low temperature rise under operation. We use a finite-element model refined with experimental measurements to determine the thermal distribution in the ion trap and the temperature at the position of the ions. The trap temperature is investigated at different rf-drive frequencies and amplitudes with an infrared camera and integrated temperature sensors. We show that for typical trapping parameters for In+, Al+, Lu+, Ca+, Sr+, or Yb+ ions, the temperature rise at the position of the ions resulting from rf heating of the trap stays below 700 mK and can be controlled with an uncertainty on the order of a few 100 mK maximum. The corresponding uncertainty of the trap-related blackbody radiation shift is in the low 10−19 and even 10−20 regime for 171Yb+(E3) and 115In+, respectively.

arXiv:2008.04231•Review of Scientific Instruments•Nov 1, 2020•15 citations
We describe a framework for calculating the frequency shift and uncertainty of trapped-ion optical atomic clocks caused by background-gas collisions, and apply this framework to an 27Al+^{27}\mathrm{Al}^{+}27Al+ clock to enable a total fractional systematic uncertainty below 10\ensuremath−18{10}^{\ensuremath{-}18}10\ensuremath−18. For this clock, with 38(19) nPa of room-temperature H2{\mathrm{H}}_{2}H2​ background gas, we find that collisional heating generates a non-thermal distribution of motional states with a mean time-dilation shift of order 10\ensuremath−16{10}^{\ensuremath{-}16}10\ensuremath−16 at the end of a 150 ms probe, which is not detected by sideband thermometry energy measurements. However, the contribution of collisional heating to the spectroscopy signal is highly suppressed and we calculate the BGC shift to be \ensuremath−0.6(2.4)\ifmmode×\else\texttimes\fi10\ensuremath−19\ensuremath{-}0.6(2.4)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}\ensuremath−0.6(2.4)\ifmmode×\else\texttimes\fi10\ensuremath−19, where the shift is due to collisional heating time dilation and the uncertainty is dominated by the worst case \ifmmode±\else\textpm\fi\ensuremathπ/2\ifmmode\pm\else\textpm\fi{}\ensuremath{\pi}/2\ifmmode±\else\textpm\fi\ensuremathπ/2 bound used for collisional phase shift of the 27Al+^{27}\mathrm{Al}^{+}27Al+ superposition state. We experimentally validate the framework and determine the background-gas pressure in situ using measurements of the rate of collisions that cause reordering of mixed-species ion pairs.
Summary form only given. As the performance of optical atomic clocks improves steadily, new sources of systematic errors need to be evaluated with increasingly higher accuracy. At present, the collisional frequency shift (CFS), due to interactions with background gas atoms in the environment of the clock ions, is in some cases the next-to-leading source of systematic uncertainty for trapped-ion optical clocks. Existing approaches towards evaluating the CFS have either assumed that only glancing-angle collisions are relevant, or assumed a worst-case scenario for the phase shift imparted to clock state superposition by a collision. The former approach, which was developed for laser-cooled cesium clocks, is not applicable to the deeply trapped atomic ions used in optical clocks, while the latter approach is likely to significantly overestimate the CFS. To address this problem we have developed a framework, based on a non-perturbative quantum channel description of the collision process. Our method leads to a convenient master equation and a compact expression for the CFS. In particular, this framework can be used to estimate the CFS in situations involving many partial waves and large collisional phase shifts, which is the case with thermal background gas atoms scattering off a clock ion. Our method lends itself to practical evaluations of the CFS, by using readily calculated molecular potential curves for the ion-background gas system to extract the collisional phase shifts which lead to the CFS. As an application of this method to a realistic and relevant situation, we have numerically estimated the frequency shift of the 674 nm clock transition in Sr+due to collisions with background helium gas. We find that the CFS is much smaller than the worst-case estimate. In this talk, we describe the theoretical background and motivate the steps that lead to our framework for calculating the CFS. Following this, we present our calculations for the Sr+-He system as an example of the general method, and discuss possible extensions and improvements that will allow us to evaluate the CFS for the Sr+clock at the National Research Council Canada.
Collisions with background gas can perturb the transition frequency of trapped ions in an optical atomic clock. We develop a nonperturbative framework based on a quantum channel description of the scattering process and use it to derive a master equation which leads to a simple analytic expression for the collisional frequency shift. As a demonstration of our method, we calculate the frequency shift of the Sr+{\mathrm{Sr}}^{+}Sr+ optical atomic clock transition due to elastic collisions with helium.
Collisions of atomic ions in optical clocks with background gas molecules result in systematic frequency shifts. We evaluate the frequency shift in Sr+{\mathrm{Sr}}^{+}Sr+ clocks due to collisions with helium atoms and hydrogen molecules, using ab initio spin-orbit-coupled potential energy surfaces together with a master equation for the collisional shift. Our results lead to improved uncertainty estimates for collisional frequency shifts in Sr+{\mathrm{Sr}}^{+}Sr+ optical clocks.
Ions possess both center-of-mass motion and internal states, rendering trapped-ion optical clocks susceptible to perturbations of both degrees of freedom, which results in systematic shifts and fluctuations with motional and relativistic origins. We develop a quantum theory that connects these effects to filter functions determined by the employed pulse sequences and show how the interrogation can be tailored to suppress or enhance specific perturbations. Our treatment includes laser frequency noise and motional effects such as recoil and Doppler shifts, micromotion and excess micromotion, as well as state-dependent trap imperfections and accelerations, e.g., caused by Stark shifts. We further account for relativistic effects including time dilation and the mass defect, and show how the same framework can be applied to hypothetical dark-matter signals. By considering ensemble-averaged phases and their variances, we characterize both systematic shifts and fluctuations, while asynchronous operation relative to the Paul-trap drive allows motional fluctuations to average down between runs. Our results provide a unified framework for characterizing and controlling the systematic and statistical contributions that determine the trueness and precision of trapped-ion optical clocks.
The uncertainty of the ac Stark shift due to thermal radiation represents a major contribution to the systematic uncertainty budget of state-of-the-art optical atomic clocks. In the case of optical clocks based on trapped ions, the thermal behavior of the rf-driven ion trap must be precisely known. This determination is even more difficult when scalable linear ion traps are used. Such traps enable a more advanced control of multiple ions and have become a platform for new applications in quantum metrology, simulation, and computation. Nevertheless, their complex structure makes it more difficult to precisely determine its temperature in operation and thus the related systematic uncertainty. We present here scalable linear ion traps for optical clocks, which exhibit very low temperature rise under operation. We use a finite-element model refined with experimental measurements to determine the thermal distribution in the ion trap and the temperature at the position of the ions. The trap temperature is investigated at different rf-drive frequencies and amplitudes with an infrared camera and integrated temperature sensors. We show that for typical trapping parameters for In+, Al+, Lu+, Ca+, Sr+, or Yb+ ions, the temperature rise at the position of the ions resulting from rf heating of the trap stays below 700 mK and can be controlled with an uncertainty on the order of a few 100 mK maximum. The corresponding uncertainty of the trap-related blackbody radiation shift is in the low 10−19 and even 10−20 regime for 171Yb+(E3) and 115In+, respectively.