arXiv:1901.06810 · Physical Review Letters

Higher-Order Quantum Ghost Imaging with Ultracold Atoms

Sean S. Hodgman, Wei Bu, S. B. Mann, R. I. Khakimov, Andrew G. Truscott

Published Jun 13, 2019• 34 citations
arXivHTMLPDF

Abstract

Ghost imaging is a quantum optics technique that uses correlations between two beams to reconstruct an image from photons that do not interact with the object being imaged. While pairwise (second-order) correlations are usually used to create the ghost image, higher-order correlations can be utilized to improve the performance. In this Letter, we demonstrate higher-order atomic ghost imaging, using entangled ultracold metastable helium atoms from an s-wave collision halo. We construct higher-order ghost images up to fifth order and show that using higher-order correlations can improve the visibility of the images without impacting the resolution. This is the first demonstration of higher-order ghost imaging with massive particles and the first higher-order ghost imaging protocol of any type using a quantum source.

DOI
10.1103/physrevlett.122.233601

Related papers

Ghost Imaging with Atoms

R. I. Khakimov, B. M. Henson, D. K. Shin +4 more

Here we report on the first realisation of ghost imaging of a macroscopic object using massive particles. The correlated pairs of ultracold metastable helium atoms are originating from two colliding Bose-Einstein condensates (BECs). We use higher-order Kapitza-Dirac scattering to generate the large number of correlated atom pairs required, enabling the creation of a ghost image with good visibility and sub-millimetre resolution. Future extensions could include ghost interference and EPR tests [1].

Frontiers in Optics•Jan 1, 2016•1 citation

Storage and retrieval of ghost images in hot atomic vapor

Young‐Wook Cho, Joo-Eon Oh, Yoon-Ho Kim

Ghost imaging is an imaging technique in which the image of an object is revealed only in the correlation measurement between two beams of light, whereas the individual measurements contain no imaging information. Here, we experimentally demonstrate storage and retrieval of ghost images in hot atomic rubidium vapor. Since ghost imaging requires (quantum or classical) multimode spatial correlation between two beams of light, our experiment shows that the spatially multimode correlation, a second-order correlation property of light, can indeed be preserved during the storage-retrieval process. Our work, thus, opens up new possibilities for quantum and classical two-photon imaging, all-optical image processing, and quantum communication.

Optics Express•Feb 24, 2012•24 citations

Ghost imaging with zero photons

Meixue Chen, Yiqi Song, Yu Gu +8 more

Ghost imaging was first demonstrated with entangled photon pairs and well-known for its peculiar properties. The signal beam that illuminates the object possesses no spatial resolution, whereas the reference beam, which never interacts with the object, is spatially resolved. Either beam alone cannot retrieve the image, which can only be obtained when the signal and reference beams are correlated. Here we will report a ghost imaging experiment with even more peculiar properties, in which the image can be reconstructed when no photon interacts with the object or even no photon in neither signal nor reference beam. All the photons interacted with the object are discarded. Only the time bins with zero photon are employed to retrieve the image, a process referred to as "ghost imaging with zero photons" hereafter. The reason why ghost image can be retrieved with zero photons is jointly determined by photon-number projection measurement and photon statistics of thermal light. The results are helpful to resolve the debate on the physics of ghost imaging and understand the relation between quantum and classical correlations.

quant-pharXiv:2604.07782•Physical Review A•Apr 10, 2026•2 citations

Improvement of the optical image reconstruction based on multiplexed quantum ghost images

Dmitriy A. Balakin, Aleksandr V. Belinsky, A. S. Chirkin

Ghost imaging allows one to obtain information on an object from the spatial correlation function between photons propagating through or reflected from the object and photons of the reference arm. In this case, detection in the object arm is performed over the entire aperture of the beam and, therefore, it does not give information on the object. The reference beam does not interact with the object, but is recorded with a scanning point detector or a CCD array permitting the measurement of the spatial correlation function of photons in two arms. The use of multimode entangled quantum light beams by illuminating the object by one beam and orienting other beams to reference arms makes it possible to obtain simultaneously several ghost images (GIs). Cross correlations of multiplexed GIs (MGIs) are determined by eighth-order field correlation functions. A special algorithm is developed for calculating higher-order correlations of Bose operators. The presence of GI cross correlations is used for improving the quality of the reconstructed object’s image by their processing using the measurement reduction method. An example of the computer simulation of the image reconstruction by MGIs formed in the field of four-frequency entangled quantum states is considered. It is found that in this case the reduced GI has a signal-to-noise ratio several times higher than that of GIs.

Journal of Experimental and Theoretical Physics•Aug 1, 2017•11 citations

Quantum and Classical Coincidence Imaging

Ryan S. Bennink, Sean J. Bentley, Robert W. Boyd +1 more

Coincidence, or ghost, imaging is a technique that uses two correlated optical fields to form an image of an object. In this work we identify aspects of coincidence imaging which can be performed with classically correlated light sources and aspects which require quantum entanglement. We find that entangled photons allow high-contrast, high-resolution imaging to be performed at any distance from the light source. We demonstrate this fact by forming ghost images in the near and far fields of an entangled photon source, noting that the product of the resolutions of these images is a factor of 3 better than that which is allowed by classical diffraction theory.

Physical Review Letters•Jan 22, 2004•417 citations

Time-to-space ghost imaging

D. B. Horoshko

Temporal ghost imaging is based on the temporal correlations of two optical beams and aims at forming a temporal image of a temporal object with a resolution, fundamentally limited by the photodetector resolution time and reaching 55 ps in a recent experiment. For further improvement of the temporal resolution, it is suggested to form a spatial ghost image of a temporal object relying on strong temporal-spatial correlations of two optical beams. Such correlations are known to exist between two entangled beams generated in type-I parametric downconversion. It is shown that a sub-picosecond-scale temporal resolution is accessible with a realistic source of entangled photons.

arXiv:2301.09184•Optics Letters•May 18, 2023•6 citations
Ghost imaging is a quantum optics technique that uses correlations between two beams to reconstruct an image from photons that do not interact with the object being imaged. While pairwise (second-order) correlations are usually used to create the ghost image, higher-order correlations can be utilized to improve the performance. In this Letter, we demonstrate higher-order atomic ghost imaging, using entangled ultracold metastable helium atoms from an s-wave collision halo. We construct higher-order ghost images up to fifth order and show that using higher-order correlations can improve the visibility of the images without impacting the resolution. This is the first demonstration of higher-order ghost imaging with massive particles and the first higher-order ghost imaging protocol of any type using a quantum source.
Here we report on the first realisation of ghost imaging of a macroscopic object using massive particles. The correlated pairs of ultracold metastable helium atoms are originating from two colliding Bose-Einstein condensates (BECs). We use higher-order Kapitza-Dirac scattering to generate the large number of correlated atom pairs required, enabling the creation of a ghost image with good visibility and sub-millimetre resolution. Future extensions could include ghost interference and EPR tests [1].
Ghost imaging is an imaging technique in which the image of an object is revealed only in the correlation measurement between two beams of light, whereas the individual measurements contain no imaging information. Here, we experimentally demonstrate storage and retrieval of ghost images in hot atomic rubidium vapor. Since ghost imaging requires (quantum or classical) multimode spatial correlation between two beams of light, our experiment shows that the spatially multimode correlation, a second-order correlation property of light, can indeed be preserved during the storage-retrieval process. Our work, thus, opens up new possibilities for quantum and classical two-photon imaging, all-optical image processing, and quantum communication.
Ghost imaging was first demonstrated with entangled photon pairs and well-known for its peculiar properties. The signal beam that illuminates the object possesses no spatial resolution, whereas the reference beam, which never interacts with the object, is spatially resolved. Either beam alone cannot retrieve the image, which can only be obtained when the signal and reference beams are correlated. Here we will report a ghost imaging experiment with even more peculiar properties, in which the image can be reconstructed when no photon interacts with the object or even no photon in neither signal nor reference beam. All the photons interacted with the object are discarded. Only the time bins with zero photon are employed to retrieve the image, a process referred to as "ghost imaging with zero photons" hereafter. The reason why ghost image can be retrieved with zero photons is jointly determined by photon-number projection measurement and photon statistics of thermal light. The results are helpful to resolve the debate on the physics of ghost imaging and understand the relation between quantum and classical correlations.
Ghost imaging allows one to obtain information on an object from the spatial correlation function between photons propagating through or reflected from the object and photons of the reference arm. In this case, detection in the object arm is performed over the entire aperture of the beam and, therefore, it does not give information on the object. The reference beam does not interact with the object, but is recorded with a scanning point detector or a CCD array permitting the measurement of the spatial correlation function of photons in two arms. The use of multimode entangled quantum light beams by illuminating the object by one beam and orienting other beams to reference arms makes it possible to obtain simultaneously several ghost images (GIs). Cross correlations of multiplexed GIs (MGIs) are determined by eighth-order field correlation functions. A special algorithm is developed for calculating higher-order correlations of Bose operators. The presence of GI cross correlations is used for improving the quality of the reconstructed object’s image by their processing using the measurement reduction method. An example of the computer simulation of the image reconstruction by MGIs formed in the field of four-frequency entangled quantum states is considered. It is found that in this case the reduced GI has a signal-to-noise ratio several times higher than that of GIs.
Coincidence, or ghost, imaging is a technique that uses two correlated optical fields to form an image of an object. In this work we identify aspects of coincidence imaging which can be performed with classically correlated light sources and aspects which require quantum entanglement. We find that entangled photons allow high-contrast, high-resolution imaging to be performed at any distance from the light source. We demonstrate this fact by forming ghost images in the near and far fields of an entangled photon source, noting that the product of the resolutions of these images is a factor of 3 better than that which is allowed by classical diffraction theory.
Temporal ghost imaging is based on the temporal correlations of two optical beams and aims at forming a temporal image of a temporal object with a resolution, fundamentally limited by the photodetector resolution time and reaching 55 ps in a recent experiment. For further improvement of the temporal resolution, it is suggested to form a spatial ghost image of a temporal object relying on strong temporal-spatial correlations of two optical beams. Such correlations are known to exist between two entangled beams generated in type-I parametric downconversion. It is shown that a sub-picosecond-scale temporal resolution is accessible with a realistic source of entangled photons.