Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1810.01712 · Physical Review A

Quantum multilateration: Subdiffraction emitter pair localization via three spatially separate Hanbury Brown and Twiss measurements

Josef G. Worboys, Daniel W. Drumm, Andrew D. Greentree

Published Jan 10, 2020• 14 citations
arXivHTMLPDF

Abstract

Typically, optical microscopy uses the wavelike properties of light to image a scene. However, photon arrival times provide more information about emitter properties than the classical intensity alone. Here we show that the Hanbury Brown and Twiss experiment (second-order correlation function) measures the relative brightness of two single-photon emitters. By combining the total number of detected photons with the zero-lag value of the correlation function, the positions and relative brightness of two emitters in two dimensions can be resolved from only three measurement positions: trilateration. This result is impossible to achieve on the basis of classical intensity measurements alone and represents a minimal demonstration of the advantage gained using quantum measurements over conventional classical microscopy. The effective point-spread function for imaging scales approximately as the inverse square root of the acquisition time.

DOI
10.1103/physreva.101.013810

Related papers

Quantum correlation microscopy localising sub-diffraction emitters in 3D

Shuo Li, Andrew D. Greentree

By applying the second order correlation of Hanbury Brown and Twiss (HBT) measurements in the quantum microscopy system we build the theory approach of localising two single-photon emitters in three dimensions under diffraction limit. The results shine light on 3D diffraction unlimited microscopy.

Imaging and Applied Optics•Jan 1, 2022•0 citations

Quantifying the advantage of photon correlation microscopy using arrays of single-photon detectors

Jaret J. Vasquez-Lozano, Qiang Sun, Shuo Li +1 more

Correlation microscopy is an emerging technique for improving optical resolution. By taking advantage of the photon statistics from single-photon fluorophores, more information about the emitters (including number and location) is obtained compared with classical microscopy. Although it is known that the resolution can be improved by increasing detector numbers, as well as using photon correlations, the quantitative relationship between these two approaches is not immediately clear. Here we explore widefield photon correlation microscopy using arrays of single-photon detectors. We explicitly compare the use of N detectors used in photon counting mode vs N/2 detectors used to measure photon correlations. i.e., where there are N/2 Hanbury Brown and Twiss systems, using the same N detectors, on randomly generated two-emitter systems and triangular three-emitter systems. We find regimes where N/2 Hanbury Brown and Twiss detectors provide improved localisation compared to N photon counting detectors, as a function of emitter position and number of photons sampled.

arXiv:2505.10794•Optics Express•Oct 1, 2025•1 citation

Quantum diffraction unlimited protocol for single-photon fluorophores

Josef G. Worboys, Daniel W. Drumm, Andrew D. Greentree

Achieving higher resolution scales in optical microscopy allow a more rigorous investigation into the detailed components of cell systems. This higher resolution is typically achieved through super-resolution techniques utilizing methods inside the wave-like nature of light such as point spread function shaping and fluorophore switching. We wish to leverage both particle-like and wave-like natures of light to make a diffraction unlimited protocol. Our protocol uses the well known Hanbury Brown and Twiss (HBT) apparatus in combination with a customized second-order cross-correlation protocol. By performing least squares fitting of the HBT and intensity measurements we obtain diffraction unlimited localization for two particles of unknown relative brightness from few measurement locations. Our results show super-resolution enhancement by an order of magnitude after 5000 detection lifetimes.

Biophotonics Australasia•Dec 30, 2019•0 citations

Localising two sub-diffraction emitters in 3D using quantum correlation microscopy

Shuo Li, Wenchao Li, Qiang Sun +4 more

Abstract The localisation of fluorophores is an important aspect of determining the biological function of cellular systems. Quantum correlation microscopy (QCM) is a promising technique for providing diffraction unlimited emitter localisation that can be used with either confocal or widefield modalities. However, so far, QCM has not been applied to three dimensional localisation problems. Here we show that QCM provides diffraction-unlimited three-dimensional localisation for two emitters within a single diffraction-limited spot. By introducing a two-stage maximum likelihood estimator, our modelling shows that the localisation precision scales as 1 / t where t is the total detection time. Diffraction unlimited localisation is achieved using both intensity and photon correlation from Hanbury Brown and Twiss measurements at as few as four measurement locations. We also compare the results of (MC) simulations with the Cramér–Rao lower bound.

arXiv:2310.02585•New Journal of Physics•Mar 1, 2024•4 citations

Generalized Hanbury Brown–Twiss interferometer

Yiqi Song, Meixue Chen, Yuhan Ma +7 more

The Hanbury Brown–Twiss (HBT) interferometer, which is used to measure the correlation of two photons or two light beams, has played a crucial role in quantum optics and quantum information. We propose a generalized HBT interferometer, which is able to measure the correlation of photons or light beams up to eight in a single experimental run. With an improved time correlated single-photon counting (TCSPC) algorithm, two-, three-, and four-photon coincidence counts, and the degree of fifth-order coherence of pseudothermal light are measured with a data collection time of 60 s. The generalized HBT interferometer can be used to measure the correlation of two multi-photon detection events by simulating photon number resolving detectors with multiple single-photon detectors. The generalized HBT interferometer and improved TCSPC algorithm provide a versatile framework for studying multi-photon correlations and interference, which is helpful to understand the physics of multi-photon interference and may find applications in fluorescence lifetime imaging and other techniques using TCSPC.

Journal of the Optical Society of America B•Mar 3, 2026•0 citations

Multi-Photon Interferences of Independent Light Sources

Steffen Oppel

In this thesis we discuss an extension of the historical Hanbury Brown and Twiss experiment and investigate spatial intensity correlations of higher-orders in the radiation field of statistically independent light sources. The light sources can be non-classical like single-photon emitters or classical, obeying thermal or coherent statistics. Although the light sources are assumed to emit the photons in an incoherent manner, we find spatial photon correlations in the far field which can be explained by the quantum mechanical concept of multi-photon interferences. We demonstrate that spatial correlation measurements between indistinguishable photons based on linear optical detection techniques can be used to overcome the resolution limit of classical optics (Abbe/Rayleigh limit) and also to manipulate the spatial radiation characteristic of the light sources. Both remarkable properties of higher-order intensity correlations have been experimentally verified using statistically independent pseudothermal light sources. Due to the fact that the reported correlation measurements require neither special quantum tailoring of light nor N-photon absorbing media, they are of particular interest for the field of quantum imaging and quantum information processing. The thesis is divided into three main parts: In the first part (Chapter 2 and 3) we introduce a quantum path formalism which allows to describe multi-photon interferences arising in both classical and nonclassical light fields. This quantum path approach explains the origin of the underlying interference mechanism of the higher-order spatial intensity correlation functions in a transparent and simple manner. Moreover, it enables us to compare the multi-photon interferences obtained by nonclassical single-photon emitters with those generated by classical light sources. In the course of this discussion it appears that Dirac's famous statement “Each photon interferes only with itself. Interference between two different photons never occurs.” should better read “A multi-photon state of independent photons only interferes with itself. Interference between different multi-photon states never occurs.” This general statement summarizes the physics behind all multi-photon interference phenomena investigated in this thesis. In the second part of the thesis (Chapter 4) we investigate particular multi-photon interference measurements of independent light sources in the context of quantum imaging. We demonstrate that the Nth-order spatial intensity correlation functions display at specific ‘magic’ detector positions the ability to filter sub-wavelength information out of the light fields arising from N incoherently radiating light sources. These multi-photon interference patterns achieve a higher resolution for N>2 than the classical Abbe/Rayleigh limit for imaging the light source. In case of N single-photon emitters we theoretically show that the super-resolving interference patterns obtained for the ‘magic’ detector positions are identical to the ones generated by NOON states with N-1 photons. Quite unexpected, the same is true for N thermal light sources, except for a reduced visibility. Experimental results with up to eight independent thermal light sources confirm this approach to improve the spatial resolution in imaging. In the last part of this thesis (Chapter 5) we finally demonstrate that multi-photon detections can lead to a strong angular focussing of incoherent photons emitted again by either uncorrelated single-photon sources or statistically independent classical light sources. For this effect the sources can be far away from each other and do not interact. The mth-order intensity correlation measurement causes source correlations which produce a heralded peaked emission pattern for the initially uncorrelated light sources. In particular, we show that if m-1 photons have been detected in a particular direction, the conditional probability to detect the mth photon in the same direction can be as high as 100 %. Owing to the great flexibility of detector positions for the correlation measurement, a wide variety of additional detection schemes exists which produces similar directional photon emission patterns. This theoretically predicted measurement-induced focussing was experimentally confirmed with up to eight pseudothermal light sources for three particular detection schemes.

•Jan 1, 2012•0 citations
Typically, optical microscopy uses the wavelike properties of light to image a scene. However, photon arrival times provide more information about emitter properties than the classical intensity alone. Here we show that the Hanbury Brown and Twiss experiment (second-order correlation function) measures the relative brightness of two single-photon emitters. By combining the total number of detected photons with the zero-lag value of the correlation function, the positions and relative brightness of two emitters in two dimensions can be resolved from only three measurement positions: trilateration. This result is impossible to achieve on the basis of classical intensity measurements alone and represents a minimal demonstration of the advantage gained using quantum measurements over conventional classical microscopy. The effective point-spread function for imaging scales approximately as the inverse square root of the acquisition time.
Correlation microscopy is an emerging technique for improving optical resolution. By taking advantage of the photon statistics from single-photon fluorophores, more information about the emitters (including number and location) is obtained compared with classical microscopy. Although it is known that the resolution can be improved by increasing detector numbers, as well as using photon correlations, the quantitative relationship between these two approaches is not immediately clear. Here we explore widefield photon correlation microscopy using arrays of single-photon detectors. We explicitly compare the use of N detectors used in photon counting mode vs N/2 detectors used to measure photon correlations. i.e., where there are N/2 Hanbury Brown and Twiss systems, using the same N detectors, on randomly generated two-emitter systems and triangular three-emitter systems. We find regimes where N/2 Hanbury Brown and Twiss detectors provide improved localisation compared to N photon counting detectors, as a function of emitter position and number of photons sampled.
Achieving higher resolution scales in optical microscopy allow a more rigorous investigation into the detailed components of cell systems. This higher resolution is typically achieved through super-resolution techniques utilizing methods inside the wave-like nature of light such as point spread function shaping and fluorophore switching. We wish to leverage both particle-like and wave-like natures of light to make a diffraction unlimited protocol. Our protocol uses the well known Hanbury Brown and Twiss (HBT) apparatus in combination with a customized second-order cross-correlation protocol. By performing least squares fitting of the HBT and intensity measurements we obtain diffraction unlimited localization for two particles of unknown relative brightness from few measurement locations. Our results show super-resolution enhancement by an order of magnitude after 5000 detection lifetimes.
Abstract The localisation of fluorophores is an important aspect of determining the biological function of cellular systems. Quantum correlation microscopy (QCM) is a promising technique for providing diffraction unlimited emitter localisation that can be used with either confocal or widefield modalities. However, so far, QCM has not been applied to three dimensional localisation problems. Here we show that QCM provides diffraction-unlimited three-dimensional localisation for two emitters within a single diffraction-limited spot. By introducing a two-stage maximum likelihood estimator, our modelling shows that the localisation precision scales as 1 / t where t is the total detection time. Diffraction unlimited localisation is achieved using both intensity and photon correlation from Hanbury Brown and Twiss measurements at as few as four measurement locations. We also compare the results of (MC) simulations with the Cramér–Rao lower bound.
The Hanbury Brown–Twiss (HBT) interferometer, which is used to measure the correlation of two photons or two light beams, has played a crucial role in quantum optics and quantum information. We propose a generalized HBT interferometer, which is able to measure the correlation of photons or light beams up to eight in a single experimental run. With an improved time correlated single-photon counting (TCSPC) algorithm, two-, three-, and four-photon coincidence counts, and the degree of fifth-order coherence of pseudothermal light are measured with a data collection time of 60 s. The generalized HBT interferometer can be used to measure the correlation of two multi-photon detection events by simulating photon number resolving detectors with multiple single-photon detectors. The generalized HBT interferometer and improved TCSPC algorithm provide a versatile framework for studying multi-photon correlations and interference, which is helpful to understand the physics of multi-photon interference and may find applications in fluorescence lifetime imaging and other techniques using TCSPC.
In this thesis we discuss an extension of the historical Hanbury Brown and Twiss experiment and investigate spatial intensity correlations of higher-orders in the radiation field of statistically independent light sources. The light sources can be non-classical like single-photon emitters or classical, obeying thermal or coherent statistics. Although the light sources are assumed to emit the photons in an incoherent manner, we find spatial photon correlations in the far field which can be explained by the quantum mechanical concept of multi-photon interferences. We demonstrate that spatial correlation measurements between indistinguishable photons based on linear optical detection techniques can be used to overcome the resolution limit of classical optics (Abbe/Rayleigh limit) and also to manipulate the spatial radiation characteristic of the light sources. Both remarkable properties of higher-order intensity correlations have been experimentally verified using statistically independent pseudothermal light sources. Due to the fact that the reported correlation measurements require neither special quantum tailoring of light nor N-photon absorbing media, they are of particular interest for the field of quantum imaging and quantum information processing. The thesis is divided into three main parts: In the first part (Chapter 2 and 3) we introduce a quantum path formalism which allows to describe multi-photon interferences arising in both classical and nonclassical light fields. This quantum path approach explains the origin of the underlying interference mechanism of the higher-order spatial intensity correlation functions in a transparent and simple manner. Moreover, it enables us to compare the multi-photon interferences obtained by nonclassical single-photon emitters with those generated by classical light sources. In the course of this discussion it appears that Dirac's famous statement “Each photon interferes only with itself. Interference between two different photons never occurs.” should better read “A multi-photon state of independent photons only interferes with itself. Interference between different multi-photon states never occurs.” This general statement summarizes the physics behind all multi-photon interference phenomena investigated in this thesis. In the second part of the thesis (Chapter 4) we investigate particular multi-photon interference measurements of independent light sources in the context of quantum imaging. We demonstrate that the Nth-order spatial intensity correlation functions display at specific ‘magic’ detector positions the ability to filter sub-wavelength information out of the light fields arising from N incoherently radiating light sources. These multi-photon interference patterns achieve a higher resolution for N>2 than the classical Abbe/Rayleigh limit for imaging the light source. In case of N single-photon emitters we theoretically show that the super-resolving interference patterns obtained for the ‘magic’ detector positions are identical to the ones generated by NOON states with N-1 photons. Quite unexpected, the same is true for N thermal light sources, except for a reduced visibility. Experimental results with up to eight independent thermal light sources confirm this approach to improve the spatial resolution in imaging. In the last part of this thesis (Chapter 5) we finally demonstrate that multi-photon detections can lead to a strong angular focussing of incoherent photons emitted again by either uncorrelated single-photon sources or statistically independent classical light sources. For this effect the sources can be far away from each other and do not interact. The mth-order intensity correlation measurement causes source correlations which produce a heralded peaked emission pattern for the initially uncorrelated light sources. In particular, we show that if m-1 photons have been detected in a particular direction, the conditional probability to detect the mth photon in the same direction can be as high as 100 %. Owing to the great flexibility of detector positions for the correlation measurement, a wide variety of additional detection schemes exists which produces similar directional photon emission patterns. This theoretically predicted measurement-induced focussing was experimentally confirmed with up to eight pseudothermal light sources for three particular detection schemes.