arXiv:1807.10405 · Physical Review A

Estimation of gravitational acceleration with quantum optical interferometers

Shuying Chen, Timothy C. Ralph

Published Feb 1, 2019• 9 citations
arXivHTMLPDF

Abstract

The precise estimation of the gravitational acceleration is important for various disciplines. We consider making such an estimation using quantum optics. A Mach-Zehnder interferometer in an ``optical fountain'' type arrangement is considered and used to define a standard quantum limit for estimating the gravitational acceleration. We use an approach based on quantum field theory on a curved, Schwarzschild metric background to calculate the coupling between the gravitational field and the optical signal. The analysis is extended to include the injection of a squeezed vacuum to the Mach-Zehnder arrangement and also to consider an active, two-mode SU(1,1) interferometer in a similar arrangement. When detection loss is larger than $8%$, the SU(1,1) interferometer shows an advantage over the MZ interferometer with single-mode squeezing input. The proposed system is based on current technology and could be used to examine the intersection of quantum theory and general relativity as well as for possible applications.

DOI
10.1103/physreva.99.023803

Related papers

Gravitational acceleration estimation with a nonlinear Mach–Zehnder interferometer

Leili Esmaeilifar, Timothy C. Ralph

We investigate the use of a nonlinear optical interferometer to estimate local gravitational acceleration. We study a Mach–Zehnder interferometer (MZI) in an optical fountain configuration where a Kerr nonlinear medium is placed in the arms of the interferometer. This configuration allows the parameter estimation to exceed the standard Heisenberg limit of a linear interferometer. Compared to previous studies, we argue that this interferometer configuration is better posed and achieves improved precision for similar scale and pump powers.

Journal of the Optical Society of America B•Dec 15, 2021•4 citations

Quantum-enhanced stochastic phase estimation with the SU(1,1) interferometer

Kaimin Zheng, Minghao Mi, Ben Wang +6 more

Quantum stochastic phase estimation has many applications in the precise measurement of various physical parameters. Similar to the estimation of a constant phase, there is a standard quantum limit for stochastic phase estimation, which can be obtained with the Mach–Zehnder interferometer and coherent input state. Recently, it has been shown that the stochastic standard quantum limit can be surpassed with nonclassical resources such as squeezed light. However, practical methods to achieve quantum enhancement in the stochastic phase estimation remain largely unexplored. Here we propose a method utilizing the SU(1,1) interferometer and coherent input states to estimate a stochastic optical phase. As an example, we investigate the Ornstein–Uhlenback stochastic phase. We analyze the performance of this method for three key estimation problems: prediction, tracking, and smoothing. The results show significant reduction of the mean square error compared with the Mach–Zehnder interferometer under the same photon number flux inside the interferometers. In particular, we show that the method with the SU(1,1) interferometer can achieve fundamental quantum scaling, achieve stochastic Heisenberg scaling, and surpass the precision of the canonical measurement.

arXiv:2008.02969•Photonics Research•Aug 4, 2020•19 citations

Quantum limits in interferometric detection of gravitational radiation

A. F. Pace, Matthew J. Collett, Daniel F. Walls

A spectral analysis is given of the quantum fluctuations in an optical interferometer to detect gravitational radiation. Two different methods of beating the standard quantum limit are examined: directing a squeezed state into the nonlaser input port of the interferometer and placing a Kerr medium into both arms of the interferometer. For both the Kerr medium and large squeezing cases the interferometer system is limited ultimately by the damping noise in the mirrors, not by noise in the light.

Physical Review A•Apr 1, 1993•169 citations

Quantum noise in optical interferometers

Volodymyr G. Voronov, Michael Weyrauch

We study the photon counting noise in optical interferometers used for gravitational wave detection. In order to reduce quantum noise, a squeezed vacuum is injected into the usually unused input port. It is investigated under which conditions the gravitational wave signal may be amplified without increasing counting noise concurrently. Such a possibility was suggested as a consequence of the entanglement of the two output ports of a beam splitter. We find that amplification without concurrent increase of noise is not possible for reasonable squeezing parameters. Photon distributions for various beam splitter angles and squeezing parameters are calculated.

arXiv:1006.4772•Physical Review A•May 11, 2010•5 citations

Phase Estimation in Linear and Nonlinear Interferometers

Sushovit Adhikari

Phase estimation has a wide range of applications. Over the years, several strategies have been studied to improve precision in phase estimation. These strategies include using exotic quantum states to quantum detection schemes. This dissertation summarizes my effort in improving the precision of phase estimation with a linear and nonlinear interferometer. Chapter 1 introduces quantum optics and quantum metrology. I introduce all relevant quantum states of light used. We also look into tools and terminologies of quantum metrology such as Fisher information, shot-noise limit, Heisenberg limit, etc., along with examples of phase estimation with a Mach-Zehnder interferometer. In Chapter 2, I discuss multiple phase estimation using a multimode interferometer. Building upon previous work, our scheme consists of a multimode interferometer with single-photon inputs. By using a quantum Fisher information analysis, we show that our scheme gives a constant improvement over other schemes. We also show that our scheme with photon-number-resolving detection approaches the quantum Cram\'er-Rao bound. Moreover, we also consider the probabilistic nature of photon emission at the input, and we study its effect on phase sensitivity. I discuss phase estimation with SU(1,1) interferometer in Chapter 3. We look at phase sensitivity in this interferometer with different input states. Namely, we consider two different phase estimation scheme, one using thermal and squeezed states, and others using coherent and displaced squeezed states with parity and on-off as a detection scheme. We also look into the effect of photon loss inside the interferometer. In Chapter 4, we revisit phase estimation in SU(1,1) interferometer from the perspective of quantum Fisher information. I discuss in detail a longstanding confusion regarding the use of quantum Fisher information in SU(1,1) interferometer. We show that phase averaging or quantum Fisher information matrix method is needed in general for calculating the phase sensitivity which resolves inconsistencies reported in previously published articles.

Civil War Book Review•Feb 22, 2019•0 citations

SU(2)-in-SU(1,1) nested interferometer

Wei Du, Jia Kong, Jun Fang Jia +6 more

The use of squeezing and entanglement allows advanced interferometers to detect signals that would otherwise be buried in quantum mechanical noise. High sensitivity instruments including magnetometers and gravitational wave detectors have shown enhanced signal-to-noise ratio (SNR) by injecting single-mode squeezed light into SU(2) interferometers, e.g. the Mach-Zehnder or Michelson topologies. The quantum enhancement in this approach is sensitive to losses, which break the fragile quantum correlations in the squeezed state. In contrast, SU(1,1) interferometers achieve quantum enhancement by noiseless amplification; they noiselessly increase the signal rather than reducing the quantum noise. Prior work on SU(1,1) interferometers has shown quantum-enhanced SNR11 and insensitivity to losses but to date has been limited to low powers and thus low SNR. Here we introduce a new interferometer topology, the SU(2)-in-SU(1,1) nested interferometer, that combines quantum enhancement, the high SNR possible with a SU(2) interferometer, and the loss tolerance of the SU(1,1) approach. We implement this interferometer using four-wave mixing in a hot atomic vapor and demonstrate 2:2(5) dB of quantum SNR enhancement, in a system with a phase variance nearly two orders of magnitude below that of any previous loss-tolerant enhancement scheme. The new interferometer enables new possibilities such as beyond-shot-noise sensing with wavelengths for which efficient detectors are not available.

•Apr 30, 2020•3 citations
The precise estimation of the gravitational acceleration is important for various disciplines. We consider making such an estimation using quantum optics. A Mach-Zehnder interferometer in an ``optical fountain'' type arrangement is considered and used to define a standard quantum limit for estimating the gravitational acceleration. We use an approach based on quantum field theory on a curved, Schwarzschild metric background to calculate the coupling between the gravitational field and the optical signal. The analysis is extended to include the injection of a squeezed vacuum to the Mach-Zehnder arrangement and also to consider an active, two-mode SU(1,1) interferometer in a similar arrangement. When detection loss is larger than 88%8, the SU(1,1) interferometer shows an advantage over the MZ interferometer with single-mode squeezing input. The proposed system is based on current technology and could be used to examine the intersection of quantum theory and general relativity as well as for possible applications.
We investigate the use of a nonlinear optical interferometer to estimate local gravitational acceleration. We study a Mach–Zehnder interferometer (MZI) in an optical fountain configuration where a Kerr nonlinear medium is placed in the arms of the interferometer. This configuration allows the parameter estimation to exceed the standard Heisenberg limit of a linear interferometer. Compared to previous studies, we argue that this interferometer configuration is better posed and achieves improved precision for similar scale and pump powers.
Quantum stochastic phase estimation has many applications in the precise measurement of various physical parameters. Similar to the estimation of a constant phase, there is a standard quantum limit for stochastic phase estimation, which can be obtained with the Mach–Zehnder interferometer and coherent input state. Recently, it has been shown that the stochastic standard quantum limit can be surpassed with nonclassical resources such as squeezed light. However, practical methods to achieve quantum enhancement in the stochastic phase estimation remain largely unexplored. Here we propose a method utilizing the SU(1,1) interferometer and coherent input states to estimate a stochastic optical phase. As an example, we investigate the Ornstein–Uhlenback stochastic phase. We analyze the performance of this method for three key estimation problems: prediction, tracking, and smoothing. The results show significant reduction of the mean square error compared with the Mach–Zehnder interferometer under the same photon number flux inside the interferometers. In particular, we show that the method with the SU(1,1) interferometer can achieve fundamental quantum scaling, achieve stochastic Heisenberg scaling, and surpass the precision of the canonical measurement.
We study the photon counting noise in optical interferometers used for gravitational wave detection. In order to reduce quantum noise, a squeezed vacuum is injected into the usually unused input port. It is investigated under which conditions the gravitational wave signal may be amplified without increasing counting noise concurrently. Such a possibility was suggested as a consequence of the entanglement of the two output ports of a beam splitter. We find that amplification without concurrent increase of noise is not possible for reasonable squeezing parameters. Photon distributions for various beam splitter angles and squeezing parameters are calculated.
Phase estimation has a wide range of applications. Over the years, several strategies have been studied to improve precision in phase estimation. These strategies include using exotic quantum states to quantum detection schemes. This dissertation summarizes my effort in improving the precision of phase estimation with a linear and nonlinear interferometer. Chapter 1 introduces quantum optics and quantum metrology. I introduce all relevant quantum states of light used. We also look into tools and terminologies of quantum metrology such as Fisher information, shot-noise limit, Heisenberg limit, etc., along with examples of phase estimation with a Mach-Zehnder interferometer. In Chapter 2, I discuss multiple phase estimation using a multimode interferometer. Building upon previous work, our scheme consists of a multimode interferometer with single-photon inputs. By using a quantum Fisher information analysis, we show that our scheme gives a constant improvement over other schemes. We also show that our scheme with photon-number-resolving detection approaches the quantum Cram\'er-Rao bound. Moreover, we also consider the probabilistic nature of photon emission at the input, and we study its effect on phase sensitivity. I discuss phase estimation with SU(1,1) interferometer in Chapter 3. We look at phase sensitivity in this interferometer with different input states. Namely, we consider two different phase estimation scheme, one using thermal and squeezed states, and others using coherent and displaced squeezed states with parity and on-off as a detection scheme. We also look into the effect of photon loss inside the interferometer. In Chapter 4, we revisit phase estimation in SU(1,1) interferometer from the perspective of quantum Fisher information. I discuss in detail a longstanding confusion regarding the use of quantum Fisher information in SU(1,1) interferometer. We show that phase averaging or quantum Fisher information matrix method is needed in general for calculating the phase sensitivity which resolves inconsistencies reported in previously published articles.
The use of squeezing and entanglement allows advanced interferometers to detect signals that would otherwise be buried in quantum mechanical noise. High sensitivity instruments including magnetometers and gravitational wave detectors have shown enhanced signal-to-noise ratio (SNR) by injecting single-mode squeezed light into SU(2) interferometers, e.g. the Mach-Zehnder or Michelson topologies. The quantum enhancement in this approach is sensitive to losses, which break the fragile quantum correlations in the squeezed state. In contrast, SU(1,1) interferometers achieve quantum enhancement by noiseless amplification; they noiselessly increase the signal rather than reducing the quantum noise. Prior work on SU(1,1) interferometers has shown quantum-enhanced SNR11 and insensitivity to losses but to date has been limited to low powers and thus low SNR. Here we introduce a new interferometer topology, the SU(2)-in-SU(1,1) nested interferometer, that combines quantum enhancement, the high SNR possible with a SU(2) interferometer, and the loss tolerance of the SU(1,1) approach. We implement this interferometer using four-wave mixing in a hot atomic vapor and demonstrate 2:2(5) dB of quantum SNR enhancement, in a system with a phase variance nearly two orders of magnitude below that of any previous loss-tolerant enhancement scheme. The new interferometer enables new possibilities such as beyond-shot-noise sensing with wavelengths for which efficient detectors are not available.