arXiv:1806.08705 · Optics Letters

Optimized ultra-narrow atomic bandpass filters via magneto-optic rotation in an unconstrained geometry

James Keaveney, Steven A. Wrathmall, Charles S. Adams, Ifan G. Hughes

Published Aug 27, 2018• 34 citations
arXivHTMLPDF

Abstract

Atomic bandpass filters are widely used in a variety of applications, owing to their high peak transmission and narrow bandwidths. Much of the previous literature has used the Faraday effect to realize these filters, where an axial magnetic field is applied across the atomic medium. Here we show that by using a non-axial magnetic field, the performance of these filters can be improved in comparison to the Faraday geometry. We optimize the performance of these filters using a numerical model and verify their performance by direct quantitative comparison with experimental data. We find excellent agreement between experiment and theory. These optimized filters could find use in many of the areas where Faraday filters are currently used, with little modification to the optical setup, allowing for improved performance with relatively little change.

DOI
10.1364/ol.43.004272

Related papers

Self-similarity of optical rotation trajectories around the Poincare sphere with application to an ultra-narrow atomic bandpass filter

James Keaveney, Dennis A. Rimmer, Ifan G. Hughes

We present an investigation of magneto-optic rotation in both the Faraday and Voigt geometries. We show that more physical insight can be gained in a comparison of the Faraday and Voigt effects by visualising optical rotation trajectories on the Poincare sphere. This insight is applied to design and experimentally demonstrate an improved ultra-narrow optical bandpass filter based on combining optical rotation from two cascaded cells - one in the Faraday geometry and one in the Voigt geometry. Our optical filter has an equivalent noise bandwidth of 0.56 GHz, and a figure-of-merit value of 1.22(2) GHz$^{-1}$ which is higher than any previously demonstrated filter on the Rb D2 line.

arXiv:1807.04652•Jul 12, 2018•1 citation

Na-Faraday rotation filtering: The optimal point

Wilhelm Kiefer, Robert Löw, Jörg Wrachtrup +1 more

Narrow-band optical filtering is required in many spectroscopy applications to suppress unwanted background light. One example is quantum communication where the fidelity is often limited by the performance of the optical filters. This limitation can be circumvented by utilizing the GHz-wide features of a Doppler broadened atomic gas. The anomalous dispersion of atomic vapours enables spectral filtering. These, so-called, Faraday anomalous dispersion optical filters (FADOFs) can be by far better than any commercial filter in terms of bandwidth, transition edge and peak transmission. We present a theoretical and experimental study on the transmission properties of a sodium vapour based FADOF with the aim to find the best combination of optical rotation and intrinsic loss. The relevant parameters, such as magnetic field, temperature, the related optical depth, and polarization state are discussed. The non-trivial interplay of these quantities defines the net performance of the filter. We determine analytically the optimal working conditions, such as transmission and the signal to background ratio and validate the results experimentally. We find a single global optimum for one specific optical path length of the filter. This can now be applied to spectroscopy, guide star applications, or sensing.

Scientific Reports•Oct 9, 2014•75 citations

Better magneto-optical filters with cascaded vapor cells

Fraser D. Logue, Jack D. Briscoe, Danielle Pizzey +2 more

Single-cell magneto-optical Faraday filters find great utility and are realized with either “wing” or “line center” spectral profiles. We show that cascading a second cell with independent axial (Faraday) or transverse (Voigt) magnetic field leads to improved performance in terms of figure of merit (FOM) and spectral profile. The first cell optically rotates the plane of polarization of light creating the high transmission window; the second cell selectively absorbs the light eliminating unwanted transmission. Using naturally abundant Rb vapor cells, we realize a Faraday–Faraday wing filter and the first, to the best of our knowledge, recorded Faraday–Voigt line center filter which show excellent agreement with theory. The two filters have FOM values of 0.86 and 1.63 GHz−1, respectively.

arXiv:2203.14767•Optics Letters•May 16, 2022•15 citations

Optimization of atomic Faraday filters in the presence of homogeneous line broadening

Mark A. Zentile, James Keaveney, Renju S. Mathew +3 more

We show that homogeneous line broadening drastically affects the performance of atomic Faraday filters. We study the effects of cell length and find that the behaviour of 'line-centre' filters are quite different from 'wing-type' filters, where the effect of self-broadening is found to be particularly important. We use a computer optimization algorithm to find the best magnetic field and temperature for Faraday filters with a range of cell lengths, and experimentally realize one particular example using a micro-fabricated 87 Rb vapour cell. We find excellent agreement between our theoretical model and experimental data.

arXiv:1504.03651•Journal of Physics B Atomic Molecular and Optical Physics•Aug 11, 2015•33 citations

Atomic Faraday filter with equivalent noise bandwidth less than 1 GHz

Mark A. Zentile, Daniel J. Whiting, James Keaveney +2 more

We demonstrate an atomic bandpass optical filter with an equivalent noise bandwidth less than 1 GHz using the D1 line in a cesium vapor. We use the ElecSus computer program to find optimal experimental parameters and find that, for important quantities, the cesium D1 line clearly outperforms other alkali metals on either D-lines. The filter simultaneously achieves a peak transmission of 77%, a passband of 310 MHz, and an equivalent noise bandwidth of 0.96 GHz, for a magnetic field of 45.3 G and a temperature of 68.0°C. Experimentally, the prediction from the model is verified. The experiment and theoretical predictions show excellent agreement.

arXiv:1502.07187•Optics Letters•Apr 22, 2015•71 citations

Cold-atom optical filtering enhanced by optical pumping

Xiaolei Guan, Wei Zhuang, Tiantian Shi +4 more

Atomic optical filters such as Faraday anomalous dispersion optical filters (FADOFs) or similar technologies can achieve very narrow optical bandwidth close to the scale of atomic linewidth, which can be greatly reduced in cold atoms. However, limited by the number of cold atoms and the size of the cold atomic cloud, the number of atoms interacting with the laser is reduced, and the transmission remains as low as 2%. In this work, we introduce the optical pumping into the cold atomic optical filter to solve this problem. Circular polarized optical pumping can produce polarization of the atomic ensemble and induce dichromatic as well as the Faraday rotation. We demonstrate a cold-atom optical filter which operates on the 87Rb 52S1/2 (F=2) to 52P3/2 (F′=2) transition at 780 nm. The filter achieves an ultranarrow bandwidth of 6.6(4) MHz, and its peak transmission is 15.6%, which is nearly 14 times higher than that of the cold-atom optical filter realized by Faraday magneto-optic effect. This scheme can be extended to almost all kinds of atomic optical filters and may find applications in self-stabilizing laser and active optical clock.

Frontiers in Physics•Dec 9, 2022•9 citations
Atomic bandpass filters are widely used in a variety of applications, owing to their high peak transmission and narrow bandwidths. Much of the previous literature has used the Faraday effect to realize these filters, where an axial magnetic field is applied across the atomic medium. Here we show that by using a non-axial magnetic field, the performance of these filters can be improved in comparison to the Faraday geometry. We optimize the performance of these filters using a numerical model and verify their performance by direct quantitative comparison with experimental data. We find excellent agreement between experiment and theory. These optimized filters could find use in many of the areas where Faraday filters are currently used, with little modification to the optical setup, allowing for improved performance with relatively little change.
We present an investigation of magneto-optic rotation in both the Faraday and Voigt geometries. We show that more physical insight can be gained in a comparison of the Faraday and Voigt effects by visualising optical rotation trajectories on the Poincare sphere. This insight is applied to design and experimentally demonstrate an improved ultra-narrow optical bandpass filter based on combining optical rotation from two cascaded cells - one in the Faraday geometry and one in the Voigt geometry. Our optical filter has an equivalent noise bandwidth of 0.56 GHz, and a figure-of-merit value of 1.22(2) GHz−1^{-1}−1 which is higher than any previously demonstrated filter on the Rb D2 line.
Narrow-band optical filtering is required in many spectroscopy applications to suppress unwanted background light. One example is quantum communication where the fidelity is often limited by the performance of the optical filters. This limitation can be circumvented by utilizing the GHz-wide features of a Doppler broadened atomic gas. The anomalous dispersion of atomic vapours enables spectral filtering. These, so-called, Faraday anomalous dispersion optical filters (FADOFs) can be by far better than any commercial filter in terms of bandwidth, transition edge and peak transmission. We present a theoretical and experimental study on the transmission properties of a sodium vapour based FADOF with the aim to find the best combination of optical rotation and intrinsic loss. The relevant parameters, such as magnetic field, temperature, the related optical depth, and polarization state are discussed. The non-trivial interplay of these quantities defines the net performance of the filter. We determine analytically the optimal working conditions, such as transmission and the signal to background ratio and validate the results experimentally. We find a single global optimum for one specific optical path length of the filter. This can now be applied to spectroscopy, guide star applications, or sensing.
Single-cell magneto-optical Faraday filters find great utility and are realized with either “wing” or “line center” spectral profiles. We show that cascading a second cell with independent axial (Faraday) or transverse (Voigt) magnetic field leads to improved performance in terms of figure of merit (FOM) and spectral profile. The first cell optically rotates the plane of polarization of light creating the high transmission window; the second cell selectively absorbs the light eliminating unwanted transmission. Using naturally abundant Rb vapor cells, we realize a Faraday–Faraday wing filter and the first, to the best of our knowledge, recorded Faraday–Voigt line center filter which show excellent agreement with theory. The two filters have FOM values of 0.86 and 1.63 GHz−1, respectively.
We show that homogeneous line broadening drastically affects the performance of atomic Faraday filters. We study the effects of cell length and find that the behaviour of 'line-centre' filters are quite different from 'wing-type' filters, where the effect of self-broadening is found to be particularly important. We use a computer optimization algorithm to find the best magnetic field and temperature for Faraday filters with a range of cell lengths, and experimentally realize one particular example using a micro-fabricated 87 Rb vapour cell. We find excellent agreement between our theoretical model and experimental data.
We demonstrate an atomic bandpass optical filter with an equivalent noise bandwidth less than 1 GHz using the D1 line in a cesium vapor. We use the ElecSus computer program to find optimal experimental parameters and find that, for important quantities, the cesium D1 line clearly outperforms other alkali metals on either D-lines. The filter simultaneously achieves a peak transmission of 77%, a passband of 310 MHz, and an equivalent noise bandwidth of 0.96 GHz, for a magnetic field of 45.3 G and a temperature of 68.0°C. Experimentally, the prediction from the model is verified. The experiment and theoretical predictions show excellent agreement.
Atomic optical filters such as Faraday anomalous dispersion optical filters (FADOFs) or similar technologies can achieve very narrow optical bandwidth close to the scale of atomic linewidth, which can be greatly reduced in cold atoms. However, limited by the number of cold atoms and the size of the cold atomic cloud, the number of atoms interacting with the laser is reduced, and the transmission remains as low as 2%. In this work, we introduce the optical pumping into the cold atomic optical filter to solve this problem. Circular polarized optical pumping can produce polarization of the atomic ensemble and induce dichromatic as well as the Faraday rotation. We demonstrate a cold-atom optical filter which operates on the 87Rb 52S1/2 (F=2) to 52P3/2 (F′=2) transition at 780 nm. The filter achieves an ultranarrow bandwidth of 6.6(4) MHz, and its peak transmission is 15.6%, which is nearly 14 times higher than that of the cold-atom optical filter realized by Faraday magneto-optic effect. This scheme can be extended to almost all kinds of atomic optical filters and may find applications in self-stabilizing laser and active optical clock.