Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1806.02181 · Nature Communications

High-resolution spectroscopy of single nuclear spins via sequential weak measurements

Matthias Pfender, Ping Wang, Hitoshi Sumiya, Shinobu Onoda, Wen Yang, Durga Bhaktavatsala Rao Dasari, Philipp Neumann, Xinyu Pan, Junichi Isoya, Ren‐Bao Liu, Jörg Wrachtrup

Published Feb 5, 2019• 96 citations
arXivHTMLPDF

Abstract

Abstract Nuclear magnetic resonance (NMR) of single spins have recently been detected by quantum sensors. However, the spectral resolution has been limited by the sensor’s relaxation to a few kHz at room temperature. This can be improved by using quantum memories, at the expense of sensitivity. In contrast, classical signals can be measured with exceptional spectral resolution by using continuous measurement techniques, without compromising sensitivity. When applied to single-spin NMR, it is critical to overcome the impact of back action inherent of quantum measurement. Here we report sequential weak measurements on a single 13C nuclear spin. The back-action causes the spin to undergo a quantum dynamics phase transition from coherent trapping to coherent oscillation. Single-spin NMR at room-temperature with a spectral resolution of 3.8 Hz is achieved. These results enable the use of measurement-correlation schemes for the detection of very weakly coupled single spins.

DOI
10.1038/s41467-019-08544-z

Related papers

Tracking the precession of single nuclear spins by weak measurements

K. S. Cujia, J. M. Boss, Konstantin Herb +2 more

Nuclear magnetic resonance (NMR) spectroscopy is a powerful technique for analyzing the structure and function of molecules, and for performing three-dimensional imaging of the spin density. At the heart of NMR spectrometers is the detection of electromagnetic radiation, in the form of a free induction decay (FID) signal, generated by nuclei precessing around an applied magnetic field. While conventional NMR requires signals from 1e12 or more nuclei, recent advances in sensitive magnetometry have dramatically lowered this number to a level where few or even individual nuclear spins can be detected. It is natural to ask whether continuous FID detection can still be applied at the single spin level, or whether quantum back-action modifies or even suppresses the NMR response. Here we report on tracking of single nuclear spin precession using periodic weak measurements. Our experimental system consists of carbon-13 nuclear spins in diamond that are weakly interacting with the electronic spin of a nearby nitrogen-vacancy center, acting as an optically readable meter qubit. We observe and minimize two important effects of quantum back-action: measurement-induced decoherence and frequency synchronization with the sampling clock. We use periodic weak measurements to demonstrate sensitive, high-resolution NMR spectroscopy of multiple nuclear spins with a priori unknown frequencies. Our method may provide the optimum route for performing single-molecule NMR at atomic resolution.

arXiv:1806.08243•Jun 21, 2018•7 citations

Watching the precession of a single nuclear spin by weak measurements.

K. S. Cujia, J. M. Boss, Jonathan Zopes +1 more

Nuclear magnetic resonance (NMR) spectroscopy is a powerful technique for analyzing the structure and function of molecules, and for performing three-dimensional imaging of the spin density. At the heart of NMR spectrometers is the detection of electromagnetic radiation, in the form of a free induction decay (FID) signal, generated by nuclei precessing around an applied magnetic field. While conventional NMR requires signals from 1e12 or more nuclei, recent advances in sensitive magnetometry have dramatically lowered this number to a level where few or even individual nuclear spins can be detected. It is natural to ask whether continuous FID detection can still be applied at the single spin level, or whether quantum back-action modifies or even suppresses the NMR response. Here we report on tracking of single nuclear spin precession using periodic weak measurements. Our experimental system consists of a 13C nuclear spin in diamond that is weakly interacting with the electronic spin of a nearby nitrogen-vacancy center, acting as an optically readable meter qubit. We observe and minimize two important effects of quantum back-action: Measurement-induced decoherence and frequency synchronization with the sampling clock. We use weak measurements to demonstrate nanoscale NMR spectroscopy with a simultaneous enhancement of the signal-to-noise ratio (SNR), frequency bandwidth and spectral resolution. Our method may provide the optimum route for performing single-molecule NMR at atomic resolution.

•Jun 21, 2018•1 citation

A quantum spectrum analyzer enhanced by a nuclear spin memory

T. Rosskopf, Jonathan Zopes, J. M. Boss +1 more

Abstract We realize a two-qubit sensor designed for achieving high-spectral resolution in quantum sensing experiments. Our sensor consists of an active “sensing qubit” and a long-lived “memory qubit”, implemented by the electronic and the nitrogen-15 nuclear spins of a nitrogen-vacancy center in diamond, respectively. Using state storage times of up to 45 ms, we demonstrate spectroscopy of external ac signals with a line width of 19 Hz (∼2.9 ppm) and of carbon-13 nuclear magnetic resonance signals with a line width of 190 Hz (∼74 ppm). This represents an up to 100-fold improvement in spectral resolution compared to measurements without nuclear memory.

arXiv:1610.03253•npj Quantum Information•Aug 22, 2017•72 citations

Nonvolatile nuclear spin memory enables sensor-unlimited nanoscale spectroscopy of small spin clusters

Matthias Pfender, Nabeel Aslam, Hitoshi Sumiya +5 more

In nanoscale metrology, dissipation of the sensor limits its performance. Strong dissipation has a negative impact on sensitivity, and sensor-target interaction even causes relaxation or dephasing of the latter. The weak dissipation of nitrogen-vacancy (NV) sensors in room temperature diamond enables detection of individual target nuclear spins, yet limits the spectral resolution of nuclear magnetic resonance (NMR) spectroscopy to several hundred Hertz, which typically prevents molecular recognition. Here, we use the NV intrinsic nuclear spin as a nonvolatile classical memory to store NMR information, while suppressing sensor back-action on the target using controlled decoupling of sensor, memory, and target. We demonstrate memory lifetimes up to 4 min and apply measurement and decoupling protocols, which exploit such memories efficiently. Our universal NV-based sensor device records single-spin NMR spectra with 13 Hz resolution at room temperature.Dissipation of the sensor is a limiting factor in metrology. Here, Pfender et al. suppress this effect employing the nuclear spin of an NV centre for robust intermediate storage of classical NMR information, allowing then to record single-spin NMR spectra with 13 Hz resolution at room temperature.

arXiv:1610.05675•Nature Communications•Oct 4, 2017•88 citations

High-resolution, Wide-frequency-range Magnetic Spectroscopy with Solid-state Spin Ensembles

Ronald Lee Walsworth, Zechuan Yin, Justin J. Welter +2 more

Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.

•Jan 24, 2025•0 citations

Quantum spectroscopy of single spins assisted by a classical clock

Tuvia Gefen, Maxim Khodas, Liam Paul McGuinness +2 more

Quantum spectroscopy with single two-level systems has considerably improved our ability to detect weak signals. Recently it was realized that for classical signals, precision and resolution of quantum spectroscopy is limited mainly by coherence of the signal and the stability of the clock used to measure time. The coherence time of the quantum probe, which can be significantly shorter, is not a major limiting factor in resolution measurements. Here, we address a similar question for spectroscopy of quantum signals, for example, a quantum sensor is used to detect a single nuclear spin. We present and analyze a novel correlation spectroscopy technique with performance that is limited by the coherence time of the target spins and the stability of the clock.

arXiv:1612.07225•Physical Review A•Jul 27, 2018•20 citations
Abstract Nuclear magnetic resonance (NMR) of single spins have recently been detected by quantum sensors. However, the spectral resolution has been limited by the sensor’s relaxation to a few kHz at room temperature. This can be improved by using quantum memories, at the expense of sensitivity. In contrast, classical signals can be measured with exceptional spectral resolution by using continuous measurement techniques, without compromising sensitivity. When applied to single-spin NMR, it is critical to overcome the impact of back action inherent of quantum measurement. Here we report sequential weak measurements on a single 13C nuclear spin. The back-action causes the spin to undergo a quantum dynamics phase transition from coherent trapping to coherent oscillation. Single-spin NMR at room-temperature with a spectral resolution of 3.8 Hz is achieved. These results enable the use of measurement-correlation schemes for the detection of very weakly coupled single spins.
Nuclear magnetic resonance (NMR) spectroscopy is a powerful technique for analyzing the structure and function of molecules, and for performing three-dimensional imaging of the spin density. At the heart of NMR spectrometers is the detection of electromagnetic radiation, in the form of a free induction decay (FID) signal, generated by nuclei precessing around an applied magnetic field. While conventional NMR requires signals from 1e12 or more nuclei, recent advances in sensitive magnetometry have dramatically lowered this number to a level where few or even individual nuclear spins can be detected. It is natural to ask whether continuous FID detection can still be applied at the single spin level, or whether quantum back-action modifies or even suppresses the NMR response. Here we report on tracking of single nuclear spin precession using periodic weak measurements. Our experimental system consists of carbon-13 nuclear spins in diamond that are weakly interacting with the electronic spin of a nearby nitrogen-vacancy center, acting as an optically readable meter qubit. We observe and minimize two important effects of quantum back-action: measurement-induced decoherence and frequency synchronization with the sampling clock. We use periodic weak measurements to demonstrate sensitive, high-resolution NMR spectroscopy of multiple nuclear spins with a priori unknown frequencies. Our method may provide the optimum route for performing single-molecule NMR at atomic resolution.
Nuclear magnetic resonance (NMR) spectroscopy is a powerful technique for analyzing the structure and function of molecules, and for performing three-dimensional imaging of the spin density. At the heart of NMR spectrometers is the detection of electromagnetic radiation, in the form of a free induction decay (FID) signal, generated by nuclei precessing around an applied magnetic field. While conventional NMR requires signals from 1e12 or more nuclei, recent advances in sensitive magnetometry have dramatically lowered this number to a level where few or even individual nuclear spins can be detected. It is natural to ask whether continuous FID detection can still be applied at the single spin level, or whether quantum back-action modifies or even suppresses the NMR response. Here we report on tracking of single nuclear spin precession using periodic weak measurements. Our experimental system consists of a 13C nuclear spin in diamond that is weakly interacting with the electronic spin of a nearby nitrogen-vacancy center, acting as an optically readable meter qubit. We observe and minimize two important effects of quantum back-action: Measurement-induced decoherence and frequency synchronization with the sampling clock. We use weak measurements to demonstrate nanoscale NMR spectroscopy with a simultaneous enhancement of the signal-to-noise ratio (SNR), frequency bandwidth and spectral resolution. Our method may provide the optimum route for performing single-molecule NMR at atomic resolution.
Abstract We realize a two-qubit sensor designed for achieving high-spectral resolution in quantum sensing experiments. Our sensor consists of an active “sensing qubit” and a long-lived “memory qubit”, implemented by the electronic and the nitrogen-15 nuclear spins of a nitrogen-vacancy center in diamond, respectively. Using state storage times of up to 45 ms, we demonstrate spectroscopy of external ac signals with a line width of 19 Hz (∼2.9 ppm) and of carbon-13 nuclear magnetic resonance signals with a line width of 190 Hz (∼74 ppm). This represents an up to 100-fold improvement in spectral resolution compared to measurements without nuclear memory.
In nanoscale metrology, dissipation of the sensor limits its performance. Strong dissipation has a negative impact on sensitivity, and sensor-target interaction even causes relaxation or dephasing of the latter. The weak dissipation of nitrogen-vacancy (NV) sensors in room temperature diamond enables detection of individual target nuclear spins, yet limits the spectral resolution of nuclear magnetic resonance (NMR) spectroscopy to several hundred Hertz, which typically prevents molecular recognition. Here, we use the NV intrinsic nuclear spin as a nonvolatile classical memory to store NMR information, while suppressing sensor back-action on the target using controlled decoupling of sensor, memory, and target. We demonstrate memory lifetimes up to 4 min and apply measurement and decoupling protocols, which exploit such memories efficiently. Our universal NV-based sensor device records single-spin NMR spectra with 13 Hz resolution at room temperature.Dissipation of the sensor is a limiting factor in metrology. Here, Pfender et al. suppress this effect employing the nuclear spin of an NV centre for robust intermediate storage of classical NMR information, allowing then to record single-spin NMR spectra with 13 Hz resolution at room temperature.
Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.
Quantum spectroscopy with single two-level systems has considerably improved our ability to detect weak signals. Recently it was realized that for classical signals, precision and resolution of quantum spectroscopy is limited mainly by coherence of the signal and the stability of the clock used to measure time. The coherence time of the quantum probe, which can be significantly shorter, is not a major limiting factor in resolution measurements. Here, we address a similar question for spectroscopy of quantum signals, for example, a quantum sensor is used to detect a single nuclear spin. We present and analyze a novel correlation spectroscopy technique with performance that is limited by the coherence time of the target spins and the stability of the clock.