Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1805.02358 · Journal of the Optical Society of America B

Effects of loss on the phase sensitivity with parity detection in an SU(1,1) interferometer

Dong Li, Chun-Hua Yuan, Yao Yao, Wei Jiang, Mo Li, Weiping Zhang

Published Apr 11, 2018• 32 citations
arXivHTMLPDF

Abstract

We theoretically study the effects of loss on the phase sensitivity of an SU(1,1) interferometer with parity detection with various input states. We show that although the sensitivity of phase estimation decreases in the presence of loss, it can still beat the shot-noise limit with small loss. To examine the performance of parity detection, the comparison is performed among homodyne detection, intensity detection, and parity detection. Compared with homodyne detection and intensity detection, parity detection has a slightly better optimal phase sensitivity in the absence of loss but has a worse optimal phase sensitivity with a significant amount of loss with one-coherent state or coherent ⊗ squeezed state input.

DOI
10.1364/josab.35.001080

Related papers

Sub-shot-noise-limited phase estimation via SU(1,1) interferometer with thermal states

Xiaoping Ma, Chenglong You, Sushovit Adhikari +4 more

We theoretically study the phase sensitivity of an SU(1,1) interferometer with a thermal state and a squeezed vacuum state as inputs and parity detection as the measurement. We find that the phase sensitivity can beat the shot-noise limit and approaches the Heisenberg limit, with increasing input photon number, in an ideal situation. We also consider the effect of various noises, including photon loss, dark counts, and thermal photon noise. Our results show that the phase sensitivity is below the shot-noise limit with photon loss and dark counts, but cannot beat the shot-noise limit in the presence of thermal noise.

arXiv:1711.03635•Optics Express•Jul 3, 2018•24 citations

Phase sensitivity of a lossy truncated SU(1,1) interferometer with double-port homodyne detection

Yu-Wei 煜伟 Xiao 肖, Yue Ji, Jun Wei +2 more

Abstract We theoretically investigate the phase sensitivity of a truncated SU(1,1) interferometer fed with a two-mode coherent state and employing double-port homodyne detection. On the one hand, we analytically demonstrate that the two-mode coherent state provides better phase sensitivity than the single-mode coherent state. In addition, we show that the double-port homodyne detection is a quasi-optimal measurement. For a bright coherent-state input, the sensitivity of this scheme saturates the phase-sensitivity bound determined by the quantum Fisher information. On the other hand, we quantitatively illustrate the advantage of double-port homodyne detection over the single-port scheme under ideal conditions and in the presence of photon loss, respectively. Furthermore, our analysis indicates that the scheme we propose is robust against photon loss.

Chinese Physics B•Aug 20, 2025•2 citations

Sensitivity Evaluation of SU(1,1) Interferometers with Arbitrary Input Probe State and Homodyne Detections

Sonu Jana, Dhruv Baheti, Paul Grossiord +3 more

We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses. In this systematic review, both full SU(1,1) interferometers with two parametric amplifiers and the truncated interferometers with only one parametric amplifier are examined. We investigate scenarios involving both single-output ports and joint homodyne detection, and consider parametric amplifiers with equal gains or with a boosted gain second amplifier. Our analytical formulation provides physical insight and understanding of the improvements in the sensitivity, which are shown to originate from noise reduction and/or signal amplification, depending on the configurations and practical implementations. Surprisingly, the configuration with single-output mode detection and parametric amplifiers with equal gains exhibits the highest robustness to very high internal losses. We finally apply this framework to a ubiquitous $|α,0\rangle$ input two-mode coherent probe state. This approach permits the comparison of different strategies and the optimization of the interferometer performance in the presence of losses. In particular, we determine which amplification and detection configurations provide the best performance, depending on the level of losses. This exemplifies how this general analytical approach provides a powerful tool to design quantum-enhanced interferometers and achieve optimal sensitivity with selected probe states and homodyne detection.

quant-pharXiv:2605.22029•May 22, 2026•1 citation

Quantum optical metrology in the lossy SU(2) and SU(1,1) interferometers

Yang Gao

We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.

arXiv:1606.08966•Physical Review A•Aug 18, 2016•25 citations

The Super Phase Sensitivity of an SU(1,1) Interferometer with a Two-Mode Squeezed Coherent State via Balanced Homodyne and Intensity Detection

Changlan Xu, Lei Wang, Shaoqiu Ke +2 more

We propose a novel scheme that is used for the enhancement of phase sensitivity. The SU(1,1) interferometer with a two-mode squeezed coherent state input, using balanced homodyne detection (BHD) and intensity detection (ID), is shown. Our results demonstrate that the phase sensitivity achieved via BHD outperforms that of ID. The optimal phase sensitivity via BHD surpasses the Heisenberg limit (HL) and approaches the quantum Cramér–Rao bound. A larger photon number and parameter strength can make the phase sensitivity better. Furthermore, we show the effects of internal and external losses on phase sensitivity in detail. When external loss reaches 10%, the phase sensitivity can reach the HL. Next, we have a detailed discussion on the impact of the squeezing parameter and photon number on phase sensitivity, which shows that our scheme has better phase sensitivity and enhanced robustness. This interferometer system thus holds significant potential for applications in quantum precision measurement.

Photonics•Mar 23, 2026•1 citation

Phase sensitivity of an $\operatorname{SU}(1,1)$ interferometer via product detection

Qingle Wang, Yami Fang, Xiaoping Ma +1 more

Abstract We theoretically analyze the phase sensitivity of an $\operatorname{SU}(1,1)$ SU ( 1 , 1 ) interferometer with various input states by product detection in this paper. This interferometer consists of two parametric amplifiers that play the role of beam splitters in a traditional Mach–Zehnder interferometer. The product of the amplitude quadrature of one output mode and the momentum quadrature of the other output mode is measured via balanced homodyne detection. We show that product detection has the same phase sensitivity as parity detection for most cases, and it is even better in the case with two coherent states at the input ports. The phase sensitivity is also compared with the Heisenberg limit and the quantum Cramér–Rao bound of the $\operatorname{SU}(1,1)$ SU ( 1 , 1 ) interferometer. This detection scheme can be easily implemented with current homodyne technology, which makes it highly feasible. It can be widely applied in the field of quantum metrology.

EPJ Quantum Technology•Aug 17, 2021•5 citations
We theoretically study the effects of loss on the phase sensitivity of an SU(1,1) interferometer with parity detection with various input states. We show that although the sensitivity of phase estimation decreases in the presence of loss, it can still beat the shot-noise limit with small loss. To examine the performance of parity detection, the comparison is performed among homodyne detection, intensity detection, and parity detection. Compared with homodyne detection and intensity detection, parity detection has a slightly better optimal phase sensitivity in the absence of loss but has a worse optimal phase sensitivity with a significant amount of loss with one-coherent state or coherent ⊗ squeezed state input.
We theoretically study the phase sensitivity of an SU(1,1) interferometer with a thermal state and a squeezed vacuum state as inputs and parity detection as the measurement. We find that the phase sensitivity can beat the shot-noise limit and approaches the Heisenberg limit, with increasing input photon number, in an ideal situation. We also consider the effect of various noises, including photon loss, dark counts, and thermal photon noise. Our results show that the phase sensitivity is below the shot-noise limit with photon loss and dark counts, but cannot beat the shot-noise limit in the presence of thermal noise.
Abstract We theoretically investigate the phase sensitivity of a truncated SU(1,1) interferometer fed with a two-mode coherent state and employing double-port homodyne detection. On the one hand, we analytically demonstrate that the two-mode coherent state provides better phase sensitivity than the single-mode coherent state. In addition, we show that the double-port homodyne detection is a quasi-optimal measurement. For a bright coherent-state input, the sensitivity of this scheme saturates the phase-sensitivity bound determined by the quantum Fisher information. On the other hand, we quantitatively illustrate the advantage of double-port homodyne detection over the single-port scheme under ideal conditions and in the presence of photon loss, respectively. Furthermore, our analysis indicates that the scheme we propose is robust against photon loss.
We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses. In this systematic review, both full SU(1,1) interferometers with two parametric amplifiers and the truncated interferometers with only one parametric amplifier are examined. We investigate scenarios involving both single-output ports and joint homodyne detection, and consider parametric amplifiers with equal gains or with a boosted gain second amplifier. Our analytical formulation provides physical insight and understanding of the improvements in the sensitivity, which are shown to originate from noise reduction and/or signal amplification, depending on the configurations and practical implementations. Surprisingly, the configuration with single-output mode detection and parametric amplifiers with equal gains exhibits the highest robustness to very high internal losses. We finally apply this framework to a ubiquitous ∣α,0⟩|α,0\rangle∣α,0⟩ input two-mode coherent probe state. This approach permits the comparison of different strategies and the optimization of the interferometer performance in the presence of losses. In particular, we determine which amplification and detection configurations provide the best performance, depending on the level of losses. This exemplifies how this general analytical approach provides a powerful tool to design quantum-enhanced interferometers and achieve optimal sensitivity with selected probe states and homodyne detection.
We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.
We propose a novel scheme that is used for the enhancement of phase sensitivity. The SU(1,1) interferometer with a two-mode squeezed coherent state input, using balanced homodyne detection (BHD) and intensity detection (ID), is shown. Our results demonstrate that the phase sensitivity achieved via BHD outperforms that of ID. The optimal phase sensitivity via BHD surpasses the Heisenberg limit (HL) and approaches the quantum Cramér–Rao bound. A larger photon number and parameter strength can make the phase sensitivity better. Furthermore, we show the effects of internal and external losses on phase sensitivity in detail. When external loss reaches 10%, the phase sensitivity can reach the HL. Next, we have a detailed discussion on the impact of the squeezing parameter and photon number on phase sensitivity, which shows that our scheme has better phase sensitivity and enhanced robustness. This interferometer system thus holds significant potential for applications in quantum precision measurement.
Phase sensitivity of an SU⁡(1,1)\operatorname{SU}(1,1)SU(1,1) interferometer via product detection
Abstract We theoretically analyze the phase sensitivity of an SU⁡(1,1)\operatorname{SU}(1,1)SU(1,1) SU ( 1 , 1 ) interferometer with various input states by product detection in this paper. This interferometer consists of two parametric amplifiers that play the role of beam splitters in a traditional Mach–Zehnder interferometer. The product of the amplitude quadrature of one output mode and the momentum quadrature of the other output mode is measured via balanced homodyne detection. We show that product detection has the same phase sensitivity as parity detection for most cases, and it is even better in the case with two coherent states at the input ports. The phase sensitivity is also compared with the Heisenberg limit and the quantum Cramér–Rao bound of the SU⁡(1,1)\operatorname{SU}(1,1)SU(1,1) SU ( 1 , 1 ) interferometer. This detection scheme can be easily implemented with current homodyne technology, which makes it highly feasible. It can be widely applied in the field of quantum metrology.