Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1802.03845 · Physical review. B./Physical review. B

T2 -limited sensing of static magnetic fields via fast rotation of quantum spins

A. A. Wood, A. G. Aeppli, Emmanuel Lilette, Yaakov Y. Fein, Alastair D. Stacey, Lloyd C. L. Hollenberg, Robert E Scholten, A. Martin

Published Nov 28, 2018• 26 citations
arXivHTMLPDF

Abstract

Diamond-based quantum magnetometers are more sensitive to oscillating (ac) magnetic fields than static (dc) fields because the crystal impurity-induced ensemble dephasing time ${T}_{2}^{*}$, the relevant sensing time for a dc field, is much shorter than the spin coherence time ${T}_{2}$, which determines the sensitivity to ac fields. Here we demonstrate measurement of dc magnetic fields using a physically rotating ensemble of nitrogen-vacancy centers at a precision ultimately limited by ${T}_{2}$ rather than ${T}_{2}^{*}$. The rotation period of the diamond is comparable to ${T}_{2}$ and the angle between the nitrogen-vacancy (NV) axis and the target magnetic field changes as a function of time, thus upconverting the static magnetic field to an oscillating field in the physically rotating frame. Using spin-echo interferometry of the rotating NV centers, we are able to perform measurements for over 100 times longer compared to a conventional Ramsey experiment. With modifications our scheme could realize dc sensitivities equivalent to demonstrated NV center ac magnetic field sensitivities of order $0.1\phantom{\rule{0.28em}{0ex}}\mathrm{nT}\phantom{\rule{0.16em}{0ex}}{\mathrm{Hz}}^{\ensuremath{-}1/2}$.

DOI
10.1103/physrevb.98.174114

Related papers

Improved sensitivity to magnetic fields by rotation of quantum sensors

A. A. Wood, A. G. Aeppli, Emmanuel Lilette +5 more

Magnetic sensors are typically much more sensitive to oscillating (AC) magnetic fields than static (DC) fields, due to the presence of more noise at lower frequency, typically scaling with a $1/f$ dependence. For quantum magnetometers, this characteristic noise is reflected in the ensemble dephasing time $T_2^*$, the relevant sensing time for a DC field, being much lower than the spin coherence time $T_2$, which determines the sensitivity to AC fields. Here, we demonstrate measurement of DC magnetic fields using a physically rotating ensemble of nitrogen-vacancy centres at a precision limited by the electron spin coherence time, $T_2$. We rotate the host diamond with a period comparable to $T_2$, such that the angle between the NV axis and the magnetic field to be detected changes as a function of time, upconverting the static magnetic field to an oscillating field in the physically rotating frame. Using spin-echo interferometry, we observe an order of magnitude improvement in DC magnetometer response compared to a conventional Ramsey experiments. Enhancements to our scheme could realise DC sensitivities equivalent to demonstrated AC magnetic field sensitivities with NV centres.

•Feb 12, 2018•0 citations

dc Quantum Magnetometry below the Ramsey Limit

A. A. Wood, Alastair D. Stacey, A. Martin

We demonstrate quantum sensing of dc magnetic fields that exceeds the sensitivity of conventional ${T}_{2}^{\ensuremath{\ast}}$-limited dc magnetometry by more than an order of magnitude. We use nitrogen-vacancy centers in a diamond rotating at periods comparable to the spin coherence time, and characterize the dependence of magnetic sensitivity on measurement time and rotation speed. Our method up-converts only the dc field of interest and preserves the quantum coherence of the sensor. These results definitively improve the sensitivity of a quantum magnetometer to dc fields, demonstrating that sensitivity below the ${T}_{2}^{\ensuremath{\ast}}$ limit is possible and can be applied to any diamond magnetometer where ${T}_{2}\ensuremath{\gg}{T}_{2}^{\ensuremath{\ast}}$ to yield an order-of-magnitude sensitivity improvement.

arXiv:2203.14230•Physical Review Applied•Nov 7, 2022•13 citations

Sensitive ac and dc magnetometry with nitrogen-vacancy-center ensembles in diamond

John F. Barry, Matthew Steinecker, Scott T. Alsid +4 more

Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review [Barry et al., Rev. Mod. Phys. 92, 015004 (2020)] suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn-echo magnetometry sequences for broadband and narrowband magnetometry, respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the nitrogen vacancies to magnetic field. The magnetometer realizes a minimum sensitivity of $460\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}$ in a broadband dc-sensitive mode and $210\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}$ in a narrowband ac mode. We describe the experimental setup in detail and highlight potential paths for future improvement.

arXiv:2305.06269•Physical Review Applied•Oct 25, 2024•104 citations

Extending coherence time of macro-scale diamond magnetometer by dynamical decoupling with coplanar waveguide resonator

Y. MASUYAMA, Kosuke Mizuno, Hayato Ozawa +5 more

Ultimate sensitivity for quantum magnetometry using nitrogen-vacancy (NV) centers in a diamond is limited by a number of NV centers and coherence time. Microwave irradiation with a high and homogeneous power density for a large detection volume is necessary to achieve a highly sensitive magnetometer. Here, we demonstrate a microwave resonator to enhance the power density of the microwave field and an optical system with a detection volume of 1.4 × 10−3 mm3. The strong microwave field enables us to achieve 48 ns Rabi oscillation which is sufficiently faster than the phase relaxation time of NV centers. This system combined with a decoupling pulse sequence, XY16, extends the spin coherence time (T2) up to 27 times longer than that with a spin echo method. Consequently, we obtained an AC magnetic field sensitivity of 10.8 pt/Hz using the dynamical decoupling pulse sequence.

arXiv:1805.10725•Review of Scientific Instruments•Dec 1, 2018•38 citations

Unraveling quantum dephasing of nitrogen-vacancy center ensembles in diamond

Jixing Zhang, Cheuk Kit Cheung, Michael Kübler +16 more

Abstract Nitrogen-vacancy (NV) center ensembles in diamond are one of the most promising solid-state quantum platforms for various sensing applications. Achieving ultimate sensitivity requires simultaneously long spin dephasing times ( $${T}_{2}^{* }$$ T 2 * ) and high NV center concentrations. In this work, we propose a systematic measurement approach to quantify the electron spin dephasing in NV center ensembles and analyze the contributions of various sources to the dephasing time, including NV-NV interactions, strain and electric field distributions, 13 C nuclear spins, and P1 electron spins. Our method is validated using a series of high-performance diamond samples, providing a comprehensive understanding of dephasing mechanisms and revealing correlations between NV concentration and different dephasing sources. Building on these insights, we outline strategies to further enhance the achievable sensitivity for DC magnetic field measurements.

arXiv:2408.14318•npj Quantum Materials•Mar 12, 2026•10 citations

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Feb 8, 2021•1 citation
Diamond-based quantum magnetometers are more sensitive to oscillating (ac) magnetic fields than static (dc) fields because the crystal impurity-induced ensemble dephasing time T2∗{T}_{2}^{*}T2∗​, the relevant sensing time for a dc field, is much shorter than the spin coherence time T2{T}_{2}T2​, which determines the sensitivity to ac fields. Here we demonstrate measurement of dc magnetic fields using a physically rotating ensemble of nitrogen-vacancy centers at a precision ultimately limited by T2{T}_{2}T2​ rather than T2∗{T}_{2}^{*}T2∗​. The rotation period of the diamond is comparable to T2{T}_{2}T2​ and the angle between the nitrogen-vacancy (NV) axis and the target magnetic field changes as a function of time, thus upconverting the static magnetic field to an oscillating field in the physically rotating frame. Using spin-echo interferometry of the rotating NV centers, we are able to perform measurements for over 100 times longer compared to a conventional Ramsey experiment. With modifications our scheme could realize dc sensitivities equivalent to demonstrated NV center ac magnetic field sensitivities of order 0.1nTHz\ensuremath−1/20.1\phantom{\rule{0.28em}{0ex}}\mathrm{nT}\phantom{\rule{0.16em}{0ex}}{\mathrm{Hz}}^{\ensuremath{-}1/2}0.1nTHz\ensuremath−1/2.
Magnetic sensors are typically much more sensitive to oscillating (AC) magnetic fields than static (DC) fields, due to the presence of more noise at lower frequency, typically scaling with a 1/f1/f1/f dependence. For quantum magnetometers, this characteristic noise is reflected in the ensemble dephasing time T2∗T_2^*T2∗​, the relevant sensing time for a DC field, being much lower than the spin coherence time T2T_2T2​, which determines the sensitivity to AC fields. Here, we demonstrate measurement of DC magnetic fields using a physically rotating ensemble of nitrogen-vacancy centres at a precision limited by the electron spin coherence time, T2T_2T2​. We rotate the host diamond with a period comparable to T2T_2T2​, such that the angle between the NV axis and the magnetic field to be detected changes as a function of time, upconverting the static magnetic field to an oscillating field in the physically rotating frame. Using spin-echo interferometry, we observe an order of magnitude improvement in DC magnetometer response compared to a conventional Ramsey experiments. Enhancements to our scheme could realise DC sensitivities equivalent to demonstrated AC magnetic field sensitivities with NV centres.
We demonstrate quantum sensing of dc magnetic fields that exceeds the sensitivity of conventional ${T}_{2}^{\ensuremath{\ast}}$-limited dc magnetometry by more than an order of magnitude. We use nitrogen-vacancy centers in a diamond rotating at periods comparable to the spin coherence time, and characterize the dependence of magnetic sensitivity on measurement time and rotation speed. Our method up-converts only the dc field of interest and preserves the quantum coherence of the sensor. These results definitively improve the sensitivity of a quantum magnetometer to dc fields, demonstrating that sensitivity below the ${T}_{2}^{\ensuremath{\ast}}$ limit is possible and can be applied to any diamond magnetometer where ${T}_{2}\ensuremath{\gg}{T}_{2}^{\ensuremath{\ast}}$ to yield an order-of-magnitude sensitivity improvement.
Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review [Barry et al., Rev. Mod. Phys. 92, 015004 (2020)] suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn-echo magnetometry sequences for broadband and narrowband magnetometry, respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the nitrogen vacancies to magnetic field. The magnetometer realizes a minimum sensitivity of 460fTs1/2460\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}460fTs1/2 in a broadband dc-sensitive mode and 210fTs1/2210\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}210fTs1/2 in a narrowband ac mode. We describe the experimental setup in detail and highlight potential paths for future improvement.
Ultimate sensitivity for quantum magnetometry using nitrogen-vacancy (NV) centers in a diamond is limited by a number of NV centers and coherence time. Microwave irradiation with a high and homogeneous power density for a large detection volume is necessary to achieve a highly sensitive magnetometer. Here, we demonstrate a microwave resonator to enhance the power density of the microwave field and an optical system with a detection volume of 1.4 × 10−3 mm3. The strong microwave field enables us to achieve 48 ns Rabi oscillation which is sufficiently faster than the phase relaxation time of NV centers. This system combined with a decoupling pulse sequence, XY16, extends the spin coherence time (T2) up to 27 times longer than that with a spin echo method. Consequently, we obtained an AC magnetic field sensitivity of 10.8 pt/Hz using the dynamical decoupling pulse sequence.
Abstract Nitrogen-vacancy (NV) center ensembles in diamond are one of the most promising solid-state quantum platforms for various sensing applications. Achieving ultimate sensitivity requires simultaneously long spin dephasing times ( T2∗{T}_{2}^{* }T2∗​ T 2 * ) and high NV center concentrations. In this work, we propose a systematic measurement approach to quantify the electron spin dephasing in NV center ensembles and analyze the contributions of various sources to the dephasing time, including NV-NV interactions, strain and electric field distributions, 13 C nuclear spins, and P1 electron spins. Our method is validated using a series of high-performance diamond samples, providing a comprehensive understanding of dephasing mechanisms and revealing correlations between NV concentration and different dephasing sources. Building on these insights, we outline strategies to further enhance the achievable sensitivity for DC magnetic field measurements.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.