Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1802.00489 · Physical Review A

Optimizing the signal-to-noise ratio of biphoton distribution measurements

Matthew C. Reichert, Hugo Defienne, Jason W. Fleischer

Published Jul 26, 2018• 22 citations
arXivHTMLPDF

Abstract

Single-photon-sensitive cameras can now be used as massively parallel coincidence counters for entangled photon pairs. This enables measurement of biphoton joint probability distributions with orders-of-magnitude greater dimensionality and faster acquisition speeds than traditional raster scanning of point detectors; to date, however, there has been no general formula available to optimize data collection. Here we analyze the dependence of such measurements on count rate, detector noise properties, and threshold levels. We derive expressions for the biphoton joint probability distribution and its signal-to-noise ratio (SNR), valid beyond the low-count regime up to detector saturation. The analysis gives operating parameters for global optimum SNR that may be specified prior to measurement. We find excellent agreement with experimental measurements within the range of validity and discuss discrepancies with the theoretical model for high thresholds. This work enables optimized measurement of the biphoton joint probability distribution in high-dimensional joint Hilbert spaces.

DOI
10.1103/physreva.98.013841

Related papers

Optimizing Coincidence Measurements of Entangled Photons

Matthew C. Reichert, Hugo Defienne, Jason W. Fleischer

We present the general SNR of coincidence measurements of joint probability of entangled-photon-pairs. Experiments with an EMCCD camera show excellent agreement for count rates up to saturation, and an optimum based on electronic noise.

Frontiers in Optics•Jan 1, 2017•0 citations

Scanning biphoton phase imaging with enhanced signal-to-noise ratio for quantum holography

Jing Gao, Jing Wang, Wen-Zheng Zhu +7 more

Biphoton phase imaging via two-photon coincidence detection is essential for quantum holography and related quantum imaging applications. Although camera-based methods have been predominantly used in previous studies, we here introduce a two-dimensional scanning method for biphoton phase imaging in quantum holography, which leverages a high-efficiency single-photon detector, improving signal-to-noise ratio (SNR). Using this platform, we obtained a quantum holographic phase image with an SNR above 19 and experimentally verified the noise-resilient nature of quantum holography under scanning-based detection. By using the brighter quantum sources, our method offers an efficient route toward faster two-photon coincidence imaging, which is expected to facilitate broader applications of quantum imaging in noisy environments.

Applied Physics Letters•May 4, 2026•0 citations

Imaging the Joint Probability Distribution of Spatially Entangled Photon Pairs with a Camera

Matthew C. Reichert, Hugo Defienne, Jason W. Fleischer

We present massively parallel coincidence counting of entangled photon pairs by measuring coincidences between all pairs of pixels in a single-photon-sensitive camera, including the case where both entangled photons arrive in the same pixel.

Imaging and Applied Optics•Jan 1, 2018•0 citations

Optimizing the use of detector arrays for measuring intensity correlations of photon pairs

D. S. Tasca, M. Edgar, Frauke Izdebski +2 more

Intensity correlation measurements form the basis of many experiments based on spontaneous parametric down-conversion. In the most common situation, two single-photon avalanche diodes and coincidence electronics are used in the detection of the photon pairs, and the coincidence count distributions are measured by making use of some scanning procedure. Here we analyze the measurement of intensity correlations using multielement detector arrays. By considering the detector parameters such as the detection and noise probabilities, we found that the mean number of detected photons that maximizes the visibility of the two-photon correlations is approximately equal to the mean number of noise events in the detector array. We provide expressions predicting the strength of the measured intensity correlations as a function of the detector parameters and on the mean number of detected photons. We experimentally test our predictions by measuring far-field intensity correlations of spontaneous parametric down-conversion with an electron multiplying charge-coupled device camera, finding excellent agreement with the theoretical analysis.

arXiv:1305.6769•Physical Review A•Jul 11, 2013•29 citations

Noise in Classical and Quantum Photon-Correlation Imaging

Bahaa E. A. Saleh, Malvin Carl Teich

Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.

SPIE eBooks•Mar 16, 2010•4 citations

Massively Parallel Coincidence Counting of High-Dimensional Entangled States

Matthew C. Reichert, Hugo Defienne, Jason W. Fleischer

Abstract Entangled states of light are essential for quantum technologies and fundamental tests of physics. Current systems rely on entanglement in 2D degrees of freedom, e.g., polarization states. Increasing the dimensionality provides exponential speed-up of quantum computation, enhances the channel capacity and security of quantum communication protocols, and enables quantum imaging; unfortunately, characterizing high-dimensional entanglement of even bipartite quantum states remains prohibitively time-consuming. Here, we develop and experimentally demonstrate a new theory of camera detection that leverages the massive parallelization inherent in an array of pixels. We show that a megapixel array, for example, can measure a joint Hilbert space of 1012 dimensions, with a speed-up of nearly four orders-of-magnitude over traditional methods. The technique uses standard geometry with existing technology, thus removing barriers of entry to quantum imaging experiments, generalizes readily to arbitrary numbers of entangled photons, and opens previously inaccessible regimes of high-dimensional quantum optics.

arXiv:1710.01781•Scientific Reports•May 15, 2018•52 citations
Single-photon-sensitive cameras can now be used as massively parallel coincidence counters for entangled photon pairs. This enables measurement of biphoton joint probability distributions with orders-of-magnitude greater dimensionality and faster acquisition speeds than traditional raster scanning of point detectors; to date, however, there has been no general formula available to optimize data collection. Here we analyze the dependence of such measurements on count rate, detector noise properties, and threshold levels. We derive expressions for the biphoton joint probability distribution and its signal-to-noise ratio (SNR), valid beyond the low-count regime up to detector saturation. The analysis gives operating parameters for global optimum SNR that may be specified prior to measurement. We find excellent agreement with experimental measurements within the range of validity and discuss discrepancies with the theoretical model for high thresholds. This work enables optimized measurement of the biphoton joint probability distribution in high-dimensional joint Hilbert spaces.
Biphoton phase imaging via two-photon coincidence detection is essential for quantum holography and related quantum imaging applications. Although camera-based methods have been predominantly used in previous studies, we here introduce a two-dimensional scanning method for biphoton phase imaging in quantum holography, which leverages a high-efficiency single-photon detector, improving signal-to-noise ratio (SNR). Using this platform, we obtained a quantum holographic phase image with an SNR above 19 and experimentally verified the noise-resilient nature of quantum holography under scanning-based detection. By using the brighter quantum sources, our method offers an efficient route toward faster two-photon coincidence imaging, which is expected to facilitate broader applications of quantum imaging in noisy environments.
Intensity correlation measurements form the basis of many experiments based on spontaneous parametric down-conversion. In the most common situation, two single-photon avalanche diodes and coincidence electronics are used in the detection of the photon pairs, and the coincidence count distributions are measured by making use of some scanning procedure. Here we analyze the measurement of intensity correlations using multielement detector arrays. By considering the detector parameters such as the detection and noise probabilities, we found that the mean number of detected photons that maximizes the visibility of the two-photon correlations is approximately equal to the mean number of noise events in the detector array. We provide expressions predicting the strength of the measured intensity correlations as a function of the detector parameters and on the mean number of detected photons. We experimentally test our predictions by measuring far-field intensity correlations of spontaneous parametric down-conversion with an electron multiplying charge-coupled device camera, finding excellent agreement with the theoretical analysis.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.
Abstract Entangled states of light are essential for quantum technologies and fundamental tests of physics. Current systems rely on entanglement in 2D degrees of freedom, e.g., polarization states. Increasing the dimensionality provides exponential speed-up of quantum computation, enhances the channel capacity and security of quantum communication protocols, and enables quantum imaging; unfortunately, characterizing high-dimensional entanglement of even bipartite quantum states remains prohibitively time-consuming. Here, we develop and experimentally demonstrate a new theory of camera detection that leverages the massive parallelization inherent in an array of pixels. We show that a megapixel array, for example, can measure a joint Hilbert space of 1012 dimensions, with a speed-up of nearly four orders-of-magnitude over traditional methods. The technique uses standard geometry with existing technology, thus removing barriers of entry to quantum imaging experiments, generalizes readily to arbitrary numbers of entangled photons, and opens previously inaccessible regimes of high-dimensional quantum optics.