The phase uncertainty of an unseeded nonlinear interferometer, where the output of one nonlinear crystal is transmitted to the input of a second crystal that analyzes it, is commonly said to be below the shot-noise level but highly dependent on detection and internal loss. Unbalancing the gains of the first (source) and second (analyzer) crystals leads to a configuration that is tolerant against detection loss. However, in terms of sensitivity, there is no advantage in choosing a stronger analyzer over a stronger source, and hence the comparison to a shot-noise level is not straightforward. Internal loss breaks this symmetry and shows that it is crucial whether the source or analyzer is dominating. Based on these results, claiming a Heisenberg scaling of the sensitivity is more subtle than in a balanced setup.
The phase uncertainty of an unseeded nonlinear interferometer, where the output of one nonlinear crystal is transmitted to the input of a second crystal that analyzes it, is commonly said to be below the shot-noise level but highly dependent on detection and internal loss. Unbalancing the gains of the first (source) and second (analyzer) crystals leads to a configuration that is tolerant against detection loss. However, in terms of sensitivity, there is no advantage in choosing a stronger analyzer over a stronger source, and hence the comparison to a shot-noise level is not straightforward. Internal loss breaks this symmetry and shows that it is crucial whether the source or analyzer is dominating. Based on these results, claiming a Heisenberg scaling of the sensitivity is more subtle than in a balanced setup.
In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is strongly unbalanced, with the parametric gain of the second amplifier exceeding the gain of the first one by a factor of 2, which makes the scheme extremely tolerant to detection losses. We show that by increasing the gain of the second amplifier, the phase supersensitivity of the interferometer can be preserved even with detection losses as high as 80%. This finding can considerably improve the state-of-the-art interferometry, enable sub-shot-noise phase sensitivity in spectral ranges with inefficient detection, and allow extension to quantum imaging.
Over the past decade, several schemes for imaging and sensing based on nonlinear interferometers have been proposed and demonstrated experimentally. These interferometers exhibit two main advantages. First, they enable probing a sample at a chosen wavelength while detecting light at a different wavelength with high efficiency (bicolor quantum imaging and sensing with undetected light). Second, they can show quantum-enhanced sensitivities below the shot-noise limit, potentially reaching Heisenberg-limited precision in parameter estimation. Here, we compare three quantum-imaging configurations using only easily accessible intensity-based measurements for phase estimation: a Yurke-type SU(1,1) interferometer, a Mandel-type induced-coherence interferometer, and a hybrid scheme that continuously interpolates between them. While an ideal Yurke interferometer can exhibit Heisenberg scaling, this advantage is known to be fragile under realistic detection constraints and in the presence of loss. We demonstrate that differential intensity detection in the Mandel interferometer provides the highest and most robust phase sensitivity among the considered schemes, reaching but not surpassing the shot-noise limit, even in the presence of loss. Intensity measurements in a Yurke-type configuration can achieve genuine sub-shot-noise sensitivity under balanced losses and moderate gain; however, their performance degrades in realistic high-gain regimes. Consequently, in this regime, the Mandel configuration with differential detection outperforms the Yurke-type setup and constitutes the most robust approach for phase estimation.
Correlated interferometry offers various advantages in precision measurements, such as sub-shot noise sensitivity, high resolution, and prevention of detector saturation benefiting from dark output. In certain practical scenarios, e.g. absorptive measurement, there is usually unbalanced loss between the probe and reference beams, which destroys the correlation and remains a significant obstacle in the efficient application of entanglements. Here, we study the performance of a nonlinear interferometer whose arms experience unbalanced loss and demonstrate the use of a phase-sensitive amplifier in the sensing or reference arms to amplify or squeeze the light field, which can both reduce the degradation of quantum enhancement from unbalanced absorption in a lossy environment. We find that the loss after amplification, i.e. from imperfect interferometry and detection, can be mitigated when the phase-sensitive amplifier is placed at the sensing arm and functions as a noiseless amplifier. Our approach may be helpful to the practical application of quantum-enhanced absorptive measurement.
We analyse a nonlinear interferometer, also known as an SU(1,1) interferometer, in the presence of internal losses and inefficient detectors. To overcome these limitations, we consider the effect of seeding one of the interferometer input modes with either a number state or a coherent state. We derive analytical expressions for the interference visibility, contrast, phase sensitivity, and signal-to-noise ratio, and show a significant enhancement in all these quantities as a function of the seeding photon number. For example, we predict that, even in the presence of substantial losses and highly inefficient detectors, we can achieve the same quantum-limited phase sensitivity of an unseeded nonlinear interferometer by seeding with a few tens of photons. Furthermore, we observe no difference between a number or a coherent seeding state when the interferometer operates in the low-gain regime, which enables seeding with an attenuated laser. Our results expand the nonlinear interferometry capabilities in the field of quantum imaging, metrology, and spectroscopy under realistic experimental conditions.
Bicolor quantum imaging can reach, in principle, phase supersensitivity approaching the Heisenberg limit using squeezed light from high-gain parametric down-conversion, but established quantum-imaging setups typically operate in the low-gain, spontaneous regime, where such scaling is inaccessible. Here, we show experimentally and theoretically that a symmetric nonlinear interferometer, even in the spontaneous regime, retains a phase-sensitivity advantage over configurations where entanglement is not exploited as a quantum-metrological resource, although the achievable phase sensitivity remains shot-noise-limited. This advantage appears as a shift of the optimal working point toward the dark fringe, the low-gain signature of the mechanism underlying high-gain supersensitivity. We derive design choices for phase-optimized nonlinear interferometers accordingly, favoring configurations that exploit entanglement as a metrological resource and specifying their optimal operating point.
A nonlinear interferometer uses nonlinear elements as beam splitters to split and to recombine optical waves for interference. As a result, the interference fringe size has a nonlinear dependence on the intensity of the field for phase sensing and leads to an enhanced phase signal. In this paper, a practical scheme of nonlinear interferometry for precision phase measurement is analyzed with parametric amplifiers as the nonlinear beam splitters. It is found that the signal due to phase shift is enhanced by a factor of the amplification gain as compared to a linear interferometer with the same phase-sensing light intensity while the quantum noise is kept at the vacuum level, thus, effectively increasing the signal-to-noise ratio (SNR) beyond the standard quantum limit. Furthermore, the scheme is not as sensitive to the detection loss as the linear scheme with a squeezed state for noise reduction. However, losses inside the interferometer limit the enhancement factor in SNR. We apply the concept to a Michelson interferometer but with parametric amplifiers involved for gravitational-wave detection. We find that effective power is increased by the gain of the amplifiers without actually increasing the cycling power inside the interferometer. Furthermore, the full benefits with squeezed input and variational output or the combination of a quantum nondemolition interferometer for sensitivity beyond the standard quantum limit apply here with even better results. Such a nonlinear interferometer will find wide applications in precision measurements.