Precise control of magnetic fields is a frequent challenge encountered in experiments with atomic quantum gases. Here we present a simple method for performing in situ monitoring of magnetic fields that can readily be implemented in any quantum-gas apparatus in which a dedicated field-stabilization approach is not feasible. The method, which works by sampling several Rabi resonances between magnetically field sensitive internal states that are not otherwise used in a given experiment, can be integrated with standard measurement sequences at arbitrary fields. For a condensate of 87Rb atoms, we demonstrate the reconstruction of Gauss-level bias fields with an accuracy of tens of microgauss and with millisecond time resolution. We test the performance of the method using measurements of slow resonant Rabi oscillations on a magnetic-field sensitive transition and give an example for its use in experiments with state-selective optical potentials.
Precise control of magnetic fields is a frequent challenge encountered in experiments with atomic quantum gases. Here we present a simple method for performing in situ monitoring of magnetic fields that can readily be implemented in any quantum-gas apparatus in which a dedicated field-stabilization approach is not feasible. The method, which works by sampling several Rabi resonances between magnetically field sensitive internal states that are not otherwise used in a given experiment, can be integrated with standard measurement sequences at arbitrary fields. For a condensate of 87Rb atoms, we demonstrate the reconstruction of Gauss-level bias fields with an accuracy of tens of microgauss and with millisecond time resolution. We test the performance of the method using measurements of slow resonant Rabi oscillations on a magnetic-field sensitive transition and give an example for its use in experiments with state-selective optical potentials.
Cold atom experiments usually need a controllable and low-noise bias magnetic field to provide a quantization axis. Most labs need home-made stabilization of the field according to the actual setup, as commercially available power supply cannot directly satisfy their requirements. Here, by measuring the field fluctuations and active feedback modulating current supply of the applied magnetic field, we successfully demonstrate a field of 10.58 G with a stability to the level of 2.8 × 10−7 in a duration of 5 min. The root mean square noise is reduced to 0.05 mG, compared to the noise of 1.3 mG without stabilization. The coherence time of the magnetic-field sensitive transition between the rubidium ground states F=1,mF=−1 and 1,0, as measured by Rabi oscillation, is extended to 19.2 ms from the unstabilized value of 1.3 ms. This result is long enough for most experiments on quantum simulation and precision measurement. As our system has no passive magnetic shielding and additional compensation coils, it is highly simple and compact to provide the stable magnetic field and would be adapted to various applications with cold atoms.
Abstract We demonstrate novel implementations of high-precision optical magnetometers which allow for spatially-selective and spatially-resolved in situ measurements using cold atomic clouds. These are realised by using shaped dispersive probe beams combined with spatially-resolved balanced homodyne detection. Two magnetometer sequences are discussed: a vectorial magnetometer, which yields sensitivities two orders of magnitude better compared to a previous realisation and a Larmor magnetometer capable of measuring absolute magnetic fields. We characterise the dependence of single-shot precision on the size of the analysed region for the vectorial magnetometer and provide a lower bound for the measurement precision of magnetic field gradients for the Larmor magnetometer. Finally, we give an outlook on how dynamic trapping potentials combined with selective probing can be used to realise enhanced quantum simulations in quantum gas microscopes.
Magnetic field sensing utilizing Bose-condensed atomic gases can achieve both high sensitivity and spatial resolution. Employing two-photon transitions from F=1, mF=1→F=2, mF=-1 (F is the quantum number of total atomic angular momentum, mF is the magnetic quantum number of F level) of Bose-condensed 87Rb atomic gases in one-dimensional optical lattice, the precision magnetic field measurement with phase Ramsey interference has been demonstrated. Utilizing single-photon transitions from F=1, mF=1→F=2, mF=0 of Bose-condensed 87Rb atomic gases in a crossed optical dipole trap, we experimentally study frequency domain Ramsey interference, time domain Ramsey interference, and phase domain Ramsey interference. Based on phase Ramsey interference, the sensitivity and spatial resolution of static magnetic field measurement are evaluated. The comparison of these three typical Ramsey interferences reveals that phase Ramsey interference can effectively avoid the fringe distortion in frequency-domain interference and the decoherence effects in time-domain interference, thereby improving the sensitivity and accuracy of the static magnetic field measurement. Utilizing Bose-condensed 87Rb atomic gases with the volume of 1.31±0.03×10-9 cm3 in an unshielded environment, a sensitivity of 130 nT/Hz for static magnetic fields can be achieved. By reducing the preparation time of the atomic gases and increasing the signal interrogation time, the sensitivity has the potential to be further improved.
A ultralow noise magnetic field is essential for many branches of scientific research. Examples include experiments conducted on ultracold atoms, quantum simulations, and precision measurements. In ultracold atom experiments specifically, a bias magnetic field will often serve as a quantization axis and be applied for Zeeman splitting. As atomic states are usually sensitive to magnetic fields, a magnetic field characterized by ultralow noise as well as high stability is typically required for experimentation. For this study, a bias magnetic field is successfully stabilized at 14.5 G, with the root mean square value of the noise reduced to 18.5 μG (1.28 ppm) by placing μ-metal magnetic shields together with a dynamical feedback circuit. Long-time instability is also regulated consistently below 7 μG. The level of noise exhibited in the bias magnetic field is further confirmed by evaluating the coherence time of a Bose-Einstein condensate characterized by Rabi oscillation. It is concluded that this approach can be applied to other physical systems as well.
Spin-exchange relaxation-free magnetometers based on dense ensembles of alkali-metal spins are precision quantum sensors that hold the record of measured and projected sensitivity to magnetic fields, in the microgauss to milligauss range. At geomagnetic fields however, these sensors quickly lose their magnetic sensitivity due to spin decoherence by random spin-exchange collisions. Here we discover that atoms with nuclear spin I=21 can operate in the spin-exchange relaxation-free regime even at high magnetic field. We counterintuitively show that frequent collisions between a dense and optically inaccessible (I=21) gas with another optically accessible spin gas (I>21) improve the fundamental magnetic sensitivity of the latter. We analyze the performance of a dual-species potassium and atomic hydrogen magnetometer and project a fundamental sensitivity of about 10aT(cm3/Hz)1/2 at geomagnetic fields for feasible experimental conditions.
We demonstrate a minimally-destructive in situ technique for measuring and stabilizing slowly-drifting magnetic fields in ultracold-atom experiments. While conventional magnetic-field sensors such as Hall, giant magnetoresistive, or fluxgate-based devices are broadly used, their accuracy, precision and dynamic range can be limited. In addition, these sensors are typically positioned at least several centimeters away from the in-vacuum atomic system, as their operation creates perturbing magnetic fields, and their placement is limited by geometric constraints imposed by the vacuum system. We overcome these issues by using the atomic system itself as a built-in magnetometer. To that end, we employ a pair of weak measurements to determine the Zeeman splitting -- and thereby the magnetic field -- of a magnetically sensitive atomic transition. We provide closed-form expressions quantifying the trade-offs between measurement noise, dynamic range, and atom loss. This procedure is demonstrated with ultracold Rb-87, weakly measured using partial-transfer absorption imaging. We then incorporate a Kalman filter to stabilize the magnetic field; this eliminated long-term drift in the ambient field (as high as ~70 nT/hr) in exchange for a modest increase in shot-to-shot variability from 1.8(2) nT to 2.0(2) nT.