Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1708.05772 · Physical Review Letters

He 3 − Xe 129 Comagnetometery using Rb 87 Detection and Decoupling

Mark E. Limes, D. Sheng, M. V. Romalis

Published Jan 16, 2018• 148 citations
arXivHTMLPDF

Abstract

We describe a ^{3}He-^{129}Xe comagnetometer using ^{87}Rb atoms for noble-gas spin polarization and detection. We use a train of ^{87}Rb π pulses and σ^{+}/σ^{-} optical pumping to realize a finite-field Rb magnetometer with suppression of spin-exchange relaxation. We suppress frequency shifts from polarized Rb by measuring the ^{3}He and ^{129}Xe spin precession frequencies in the dark, while applying π pulses along two directions to depolarize Rb atoms. The plane of the π pulses is rotated to suppress the Bloch-Siegert shifts for the nuclear spins. We measure the ratio of ^{3}He to ^{129}Xe spin precession frequencies with sufficient absolute accuracy to resolve Earth's rotation without changing the orientation of the comagnetometer. A frequency resolution of 7 nHz is achieved after integration for 8 h without evidence of significant drift.

DOI
10.1103/physrevlett.120.033401

Related papers

Spin Gyroscope is Ready to Look for New Physics

Derek F. Jackson Kimball

We describe a 3 He- 129 Xe comagnetometer using 87 Rb atoms for noble-gas spin polarization and detection.We use a train of 87 Rb π pulses and σ þ =σ -optical pumping to realize a finite-field Rb magnetometer with suppression of spin-exchange relaxation.We suppress frequency shifts from polarized Rb by measuring the 3 He and 129 Xe spin precession frequencies in the dark, while applying π pulses along two directions to depolarize Rb atoms.The plane of the π pulses is rotated to suppress the Bloch-Siegert shifts for the nuclear spins.We measure the ratio of 3 He to 129 Xe spin precession frequencies with sufficient absolute accuracy to resolve Earth's rotation without changing the orientation of the comagnetometer.A frequency resolution of 7 nHz is achieved after integration for 8 h without evidence of significant drift.

Physics•Jan 16, 2018•1 citation

Continuous comagnetometry using transversely polarized Xe isotopes

Daniel Thrasher, Susan Sorensen, J. Weber +4 more

We demonstrate a transversely polarized spin-exchange pumped noble gas comagnetometer which suppresses systematic errors from longitudinal polarization. Rb atoms as well as $^{131}\mathrm{Xe}$ and $^{129}\mathrm{Xe}$ nuclei are simultaneously polarized perpendicular to a pulsed bias field. Both Xe isotopes' nuclear magnetic resonance conditions are simultaneously satisfied by frequency modulation of the pulse repetition rate. The Rb atoms detect the Xe precession. We highlight the importance of magnetometer phase shifts when performing comagnetometry. For detection of nonmagnetic spin-dependent interactions the sensing bandwidth is 1 Hz, the white-noise level is $7\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{Hz}/\sqrt{\text{Hz}}$, and the bias instability is $\ensuremath{\sim}1$ $\ensuremath{\mu}\mathrm{Hz}$.

arXiv:1910.02156•Physical Review A•Dec 9, 2019•42 citations

Progress on a 3 He- 129 Xe co-magnetometer MARK LIMES, DONG

Michael V. Romalis

employed a Ramsey scheme with Rb used for intial spin polarization and for detection of only the initial and final phases of the two noble gas species that precess “in-the-dark.” Our current scheme attempts a continuous detection of the noble gas nuclei, which we’ve shown to increase shot-to-shot SNR over the pulsed scheme. Our technique mitigates the large difference of Fermi-contact shifts on the precession frequencies of the noble gases due to polarized Rb by making the average Rb polarization zero with respect to the noble gases. This averaging is accomplished by applying Rb pulses and simultaneously pumping with += light with a fast repetition rate. The 3 He- 129 Xe co-magnetometer has many potential applications for precision measurements, including nuclear spin gyroscopes and searches for spingravity coupling.

•Jan 1, 2015•0 citations

He 3 − Ne 21 Ramsey Comagnetometer with Sub-nHz Frequency Resolution

Shaobo Zhang, Jingyao Wang, George Sun +2 more

Nuclear spin comagnetometers offer exceptional precision in measurements of spin energy levels and exhibit long-term stability, making them powerful tools for probing spin-dependent physics beyond the standard model as well as for inertial rotation sensing. We describe a new ^{3}He-^{21}Ne Ramsey comagnetometer operating with an in situ ^{87}Rb magnetometer for initialization and sensing of nuclear spins. During free precession of nuclear spins we turn off all lasers and introduce a microwave field to suppress back action from Rb atoms. We demonstrate that scalar and dipolar interactions between nuclear spins can be eliminated via control of the polarized sample geometry. These improvements result in a bias-free measurement with a frequency sensitivity of 0.6 nHz after six hours of integration.

arXiv:2509.13486•Physical Review Letters•Feb 11, 2026•4 citations

Dual-Species Synchronous Spin-Exchange Optical Pumping

Daniel Thrasher, Susan Sorensen, Thad G Walker

We demonstrate a novel quantum sensor for measuring non-magnetic spin-dependent interactions. This sensor utilizes $^{131}$Xe, $^{129}$Xe, and $^{85}$Rb which are continuously polarized transverse to a pulsed bias field. The transverse geometry of this spin-exchange pumped comagnetometer suppresses longitudinal polarization, which is an important source of systematic error. Simultaneous excitation of both Xe isotopes is accomplished by frequency modulating the repetition rate of the bias field pulses at subharmonics of the Xe Larmor resonance frequencies. The area of each bias pulse causes $2π$ Larmor precession of the Rb. We present continuous dual-species Xe excitation and discuss a temperature-dependent wall interaction that limits the $^{129}$Xe polarization. The Rb atoms serve as an embedded magnetometer for detection of the Xe precession. We discuss Rb magnetometer phase shifts, and show that even first-order treatments of these phase shifts can result in order-of-magnitude improvements in the achieved field suppression when performing comagnetometry. The sensing bandwidth of the presented device is 1 Hz, and we demonstrate a white-noise level of 7 $μ$Hz/$\sqrt{\text{Hz}}$ and a bias instability of $\sim1$ $μ$Hz.

arXiv:1912.04991•Dec 10, 2019•5 citations

Precision frequency measurements with polarized He 3 , Ne 21 , and Xe 129 atoms

T. E. Chupp, Eduardo R. Oteiza, Jonathan M. Richardson +1 more

We present the principles, applications, and performance of new techniques developed to measure the frequency spectrum of freely precessing polarized noble-gas atoms. The noble-gas polarization technique of spin exchange with laser optically pumped Rb enables us to simultaneously polarize several species ${(}^{3}$He, $^{21}\mathrm{Ne}$, and $^{129}\mathrm{Xe}$). With signal-to-noise ratios of ${10}^{4}$, the free precession frequencies are determined with a precision of less than ${10}^{\mathrm{\ensuremath{-}}6}$ Hz out of ${10}^{3}$ Hz in 1024 s. The technique will be applied to determine frequency shifts due to dipole couplings to applied fields and quadrupole splittings due to local Lorentz-invariance-violating spatial anisotropy. In all cases, the frequencies of two or more species are measured simultaneously in order to provide magnetometry for increased precision and to provide measurement and cancellation of systematic effects.

Physical Review A•Oct 1, 1988•42 citations
We describe a ^{3}He-^{129}Xe comagnetometer using ^{87}Rb atoms for noble-gas spin polarization and detection. We use a train of ^{87}Rb π pulses and σ^{+}/σ^{-} optical pumping to realize a finite-field Rb magnetometer with suppression of spin-exchange relaxation. We suppress frequency shifts from polarized Rb by measuring the ^{3}He and ^{129}Xe spin precession frequencies in the dark, while applying π pulses along two directions to depolarize Rb atoms. The plane of the π pulses is rotated to suppress the Bloch-Siegert shifts for the nuclear spins. We measure the ratio of ^{3}He to ^{129}Xe spin precession frequencies with sufficient absolute accuracy to resolve Earth's rotation without changing the orientation of the comagnetometer. A frequency resolution of 7 nHz is achieved after integration for 8 h without evidence of significant drift.
We describe a 3 He- 129 Xe comagnetometer using 87 Rb atoms for noble-gas spin polarization and detection.We use a train of 87 Rb π pulses and σ þ =σ -optical pumping to realize a finite-field Rb magnetometer with suppression of spin-exchange relaxation.We suppress frequency shifts from polarized Rb by measuring the 3 He and 129 Xe spin precession frequencies in the dark, while applying π pulses along two directions to depolarize Rb atoms.The plane of the π pulses is rotated to suppress the Bloch-Siegert shifts for the nuclear spins.We measure the ratio of 3 He to 129 Xe spin precession frequencies with sufficient absolute accuracy to resolve Earth's rotation without changing the orientation of the comagnetometer.A frequency resolution of 7 nHz is achieved after integration for 8 h without evidence of significant drift.
We demonstrate a transversely polarized spin-exchange pumped noble gas comagnetometer which suppresses systematic errors from longitudinal polarization. Rb atoms as well as 131Xe^{131}\mathrm{Xe}131Xe and 129Xe^{129}\mathrm{Xe}129Xe nuclei are simultaneously polarized perpendicular to a pulsed bias field. Both Xe isotopes' nuclear magnetic resonance conditions are simultaneously satisfied by frequency modulation of the pulse repetition rate. The Rb atoms detect the Xe precession. We highlight the importance of magnetometer phase shifts when performing comagnetometry. For detection of nonmagnetic spin-dependent interactions the sensing bandwidth is 1 Hz, the white-noise level is $7\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{Hz}/\sqrt{\text{Hz}}$, and the bias instability is $\ensuremath{\sim}1$ $\ensuremath{\mu}\mathrm{Hz}$.
employed a Ramsey scheme with Rb used for intial spin polarization and for detection of only the initial and final phases of the two noble gas species that precess “in-the-dark.” Our current scheme attempts a continuous detection of the noble gas nuclei, which we’ve shown to increase shot-to-shot SNR over the pulsed scheme. Our technique mitigates the large difference of Fermi-contact shifts on the precession frequencies of the noble gases due to polarized Rb by making the average Rb polarization zero with respect to the noble gases. This averaging is accomplished by applying Rb pulses and simultaneously pumping with += light with a fast repetition rate. The 3 He- 129 Xe co-magnetometer has many potential applications for precision measurements, including nuclear spin gyroscopes and searches for spingravity coupling.
Nuclear spin comagnetometers offer exceptional precision in measurements of spin energy levels and exhibit long-term stability, making them powerful tools for probing spin-dependent physics beyond the standard model as well as for inertial rotation sensing. We describe a new ^{3}He-^{21}Ne Ramsey comagnetometer operating with an in situ ^{87}Rb magnetometer for initialization and sensing of nuclear spins. During free precession of nuclear spins we turn off all lasers and introduce a microwave field to suppress back action from Rb atoms. We demonstrate that scalar and dipolar interactions between nuclear spins can be eliminated via control of the polarized sample geometry. These improvements result in a bias-free measurement with a frequency sensitivity of 0.6 nHz after six hours of integration.
We demonstrate a novel quantum sensor for measuring non-magnetic spin-dependent interactions. This sensor utilizes 131^{131}131Xe, 129^{129}129Xe, and 85^{85}85Rb which are continuously polarized transverse to a pulsed bias field. The transverse geometry of this spin-exchange pumped comagnetometer suppresses longitudinal polarization, which is an important source of systematic error. Simultaneous excitation of both Xe isotopes is accomplished by frequency modulating the repetition rate of the bias field pulses at subharmonics of the Xe Larmor resonance frequencies. The area of each bias pulse causes 2π2π2π Larmor precession of the Rb. We present continuous dual-species Xe excitation and discuss a temperature-dependent wall interaction that limits the 129^{129}129Xe polarization. The Rb atoms serve as an embedded magnetometer for detection of the Xe precession. We discuss Rb magnetometer phase shifts, and show that even first-order treatments of these phase shifts can result in order-of-magnitude improvements in the achieved field suppression when performing comagnetometry. The sensing bandwidth of the presented device is 1 Hz, and we demonstrate a white-noise level of 7 μμμHz/Hz\sqrt{\text{Hz}}Hz​ and a bias instability of ∼1\sim1∼1 μμμHz.
We present the principles, applications, and performance of new techniques developed to measure the frequency spectrum of freely precessing polarized noble-gas atoms. The noble-gas polarization technique of spin exchange with laser optically pumped Rb enables us to simultaneously polarize several species (3{(}^{3}(3He, 21Ne^{21}\mathrm{Ne}21Ne, and 129Xe^{129}\mathrm{Xe}129Xe). With signal-to-noise ratios of 104{10}^{4}104, the free precession frequencies are determined with a precision of less than ${10}^{\mathrm{\ensuremath{-}}6}$ Hz out of 103{10}^{3}103 Hz in 1024 s. The technique will be applied to determine frequency shifts due to dipole couplings to applied fields and quadrupole splittings due to local Lorentz-invariance-violating spatial anisotropy. In all cases, the frequencies of two or more species are measured simultaneously in order to provide magnetometry for increased precision and to provide measurement and cancellation of systematic effects.