Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1708.01933 · Physical Review A

Cavity-enhanced photoionization of an ultracold rubidium beam for application in focused ion beams

G. ten Haaf, Steinar H. W. Wouters, Peter H. A. Mutsaers, Edgar J. D. Vredenbregt

Published Nov 13, 2017• 10 citations
arXivHTMLPDF

Abstract

A two-step photoionization strategy of an ultracold rubidium beam for application in a focused ion beam instrument is analyzed and implemented. In this strategy the atomic beam is partly selected with an aperture after which the transmitted atoms are ionized in the overlap of a tightly cylindrically focused excitation laser beam and an ionization laser beam whose power is enhanced in a build-up cavity. The advantage of this strategy, as compared to without the use of a build-up cavity, is that higher ionization degrees can be reached at higher currents. Optical Bloch equations including the photoionization process are used to calculate what ionization degree and ionization position distribution can be reached. Furthermore, the ionization strategy is tested on an ultracold beam of $^{85}\mathrm{Rb}$ atoms. The beam current is measured as a function of the excitation and ionization laser beam intensity and the selection aperture size. Although details are different, the global trends of the measurements agree well with the calculation. With a selection aperture diameter of $52\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{m}$, a current of $\left(170\ifmmode\pm\else\textpm\fi{}4\right)$ pA is measured, which according to calculations is 63% of the current equivalent of the transmitted atomic flux. Taking into account the ionization degree the ion beam peak reduced brightness is estimated at $1\ifmmode\times\else\texttimes\fi{}{10}^{7}$ A/(${\mathrm{m}}^{2}\phantom{\rule{0.16em}{0ex}}\mathrm{sr}\phantom{\rule{0.16em}{0ex}}\mathrm{eV}$).

DOI
10.1103/physreva.96.053412

Related papers

Performance predictions for a laser-intensified thermal beam for use in high-resolution focused-ion-beam instruments

Steinar H. W. Wouters, G. ten Haaf, Remy Notermans +4 more

Photoionization of a laser-cooled and compressed atomic beam from a high-flux thermal source can be used to create a high-brightness ion beam for use in focused-ion-beam instruments. Here we show using calculations and Doppler cooling simulations that an atomic rubidium beam with an equivalent brightness of $2.1\ifmmode\times\else\texttimes\fi{}{10}^{7} \mathrm{A}/(\mathrm{m}{}^{2} \mathrm{sr} \mathrm{eV})$ can be created using a compact 5 cm long two-dimensional magneto-optical compressor. If this can be conserved during the photoionization process, this leads to an ion beam brightness an order of magnitude higher than produced by a liquid metal ion source. The source is also capable of producing a flux of $6.2\ifmmode\times\else\texttimes\fi{}{10}^{9} \mathrm{s}{}^{\ensuremath{-}1}$ that results in a substantial beam current of 1 nA once fully ionized.

arXiv:1410.4350•Physical Review A•Dec 15, 2014•18 citations

Direct Magneto-Optical Compression of an Effusive Atomic Beam for Application in a High-Resolution Focused Ion Beam

G. ten Haaf, T. C. H. de Raadt, G. P. Offermans +4 more

Photoionizing a beam of ultracold atoms can provide a high-brightness ion beam, to improve resolution in focused-ion-beam nanofabrication. With this aim, the authors use laser cooling and compression to give a ${}^{85}$Rb atomic beam an equivalent brightness better than the current standard for the semiconductor industry. This could represent an important step toward smaller feature sizes in integrated circuits.

arXiv:1612.01883•Physical Review Applied•May 22, 2017•13 citations

Atomic beam source for the ultracold focused ion beam setup

Brenda R. J. Jansen

In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further. In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further.

•Jan 1, 2013•0 citations

A high brightness laser-cooled atomic beam for application in high resolution FIB

Shw Steinar Wouters, S.B. van der Geer, G. ten Haaf +2 more

A new type of high-brightness ion source is under development which employs transverse laser cooling and compression of a thermal atomic rubidium beam, followed by in-field photo-ionization. When attached to a focusing column, this Focused Ion Beam (FIB) has the advantage of supplying a higher current in a smaller spot compared to conventional LMIS-based FIBs, thus increasing both the resolution and the speed of the FIB. Furthermore, different types of ion species can be used, broadening the range of applications of the FIB. Simulations using a 10 cm long laser cooling and compression stage and a realistic ionization and acceleration structure, predict an achievable brightness for 87 Rb + of order 10 7 A/m 2 sr eV at an energy spread of less than 1 eV and a current of tens of pA. This would lead to a spot size below 5 nm. Simulations and modeling on the ionization process have led to a better understanding of stochastic heating. Experimental realization of the compact ion source has recently started with the development of an efficient high-flux atom source and a 2D laser cooler and compressor. Progress on simulations and experimental results will be reported.

•Jan 1, 2013•0 citations

Application of laser-cooling and compression to create a high resolution focused ion beam

Steinar H. W. Wouters, G. ten Haaf, Peter H. A. Mutsaers +2 more

Ultra-low temperature (1 mK) ion beams can be created by photo-ionization of a laser cooled and compressed thermal atomic beam. Full device simulations show that for rubidium ions, spot sizes down to 1 nm can be achieved at a current of 1 pA.

•Jan 1, 2015•0 citations

Simulated performance of an ultracold ion source

S.B. van der Geer, M.P. Reijnders, M. J. de Loos +3 more

At present, the smallest spot size which can be achieved with state-of-the-art focused ion beam (FIB) technology is mainly limited by the chromatic aberrations associated with the 4.5 eV energy spread of the liquid-metal ion source. Here we numerically investigate the performance of an ultracold ion source which has the potential for generating ion beams which combine high brightness with small energy spread. The source is based on creating very cold ion beams by near-threshold photoionization of a laser-cooled and trapped atomic gas. We present ab initio numerical calculations of the generation of ultracold beams in a realistic acceleration field and including all Coulomb interactions, i.e., both space charge effects and statistical Coulomb effects. These simulations demonstrate that with existing technology reduced brightness values exceeding 105 A m−2 sr−1 V−1 are feasible at an energy spread as low as 0.1 eV. The estimated spot size of the ultracold ion source in a FIB instrument ranges from 10 nm at a current of 100 pA to 0.8 nm at 1 pA.

Journal of Applied Physics•Nov 1, 2007•52 citations
A two-step photoionization strategy of an ultracold rubidium beam for application in a focused ion beam instrument is analyzed and implemented. In this strategy the atomic beam is partly selected with an aperture after which the transmitted atoms are ionized in the overlap of a tightly cylindrically focused excitation laser beam and an ionization laser beam whose power is enhanced in a build-up cavity. The advantage of this strategy, as compared to without the use of a build-up cavity, is that higher ionization degrees can be reached at higher currents. Optical Bloch equations including the photoionization process are used to calculate what ionization degree and ionization position distribution can be reached. Furthermore, the ionization strategy is tested on an ultracold beam of 85Rb^{85}\mathrm{Rb}85Rb atoms. The beam current is measured as a function of the excitation and ionization laser beam intensity and the selection aperture size. Although details are different, the global trends of the measurements agree well with the calculation. With a selection aperture diameter of 52\ensuremathμm52\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{m}52\ensuremathμm, a current of (170\ifmmode±\else\textpm\fi4)\left(170\ifmmode\pm\else\textpm\fi{}4\right)(170\ifmmode±\else\textpm\fi4) pA is measured, which according to calculations is 63% of the current equivalent of the transmitted atomic flux. Taking into account the ionization degree the ion beam peak reduced brightness is estimated at 1\ifmmode×\else\texttimes\fi1071\ifmmode\times\else\texttimes\fi{}{10}^{7}1\ifmmode×\else\texttimes\fi107 A/(m2sreV{\mathrm{m}}^{2}\phantom{\rule{0.16em}{0ex}}\mathrm{sr}\phantom{\rule{0.16em}{0ex}}\mathrm{eV}m2sreV).
Photoionization of a laser-cooled and compressed atomic beam from a high-flux thermal source can be used to create a high-brightness ion beam for use in focused-ion-beam instruments. Here we show using calculations and Doppler cooling simulations that an atomic rubidium beam with an equivalent brightness of $2.1\ifmmode\times\else\texttimes\fi{}{10}^{7} \mathrm{A}/(\mathrm{m}{}^{2} \mathrm{sr} \mathrm{eV})$ can be created using a compact 5 cm long two-dimensional magneto-optical compressor. If this can be conserved during the photoionization process, this leads to an ion beam brightness an order of magnitude higher than produced by a liquid metal ion source. The source is also capable of producing a flux of $6.2\ifmmode\times\else\texttimes\fi{}{10}^{9} \mathrm{s}{}^{\ensuremath{-}1}$ that results in a substantial beam current of 1 nA once fully ionized.
Photoionizing a beam of ultracold atoms can provide a high-brightness ion beam, to improve resolution in focused-ion-beam nanofabrication. With this aim, the authors use laser cooling and compression to give a 85{}^{85}85Rb atomic beam an equivalent brightness better than the current standard for the semiconductor industry. This could represent an important step toward smaller feature sizes in integrated circuits.
In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further. In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further.
A new type of high-brightness ion source is under development which employs transverse laser cooling and compression of a thermal atomic rubidium beam, followed by in-field photo-ionization. When attached to a focusing column, this Focused Ion Beam (FIB) has the advantage of supplying a higher current in a smaller spot compared to conventional LMIS-based FIBs, thus increasing both the resolution and the speed of the FIB. Furthermore, different types of ion species can be used, broadening the range of applications of the FIB. Simulations using a 10 cm long laser cooling and compression stage and a realistic ionization and acceleration structure, predict an achievable brightness for 87 Rb + of order 10 7 A/m 2 sr eV at an energy spread of less than 1 eV and a current of tens of pA. This would lead to a spot size below 5 nm. Simulations and modeling on the ionization process have led to a better understanding of stochastic heating. Experimental realization of the compact ion source has recently started with the development of an efficient high-flux atom source and a 2D laser cooler and compressor. Progress on simulations and experimental results will be reported.
At present, the smallest spot size which can be achieved with state-of-the-art focused ion beam (FIB) technology is mainly limited by the chromatic aberrations associated with the 4.5 eV energy spread of the liquid-metal ion source. Here we numerically investigate the performance of an ultracold ion source which has the potential for generating ion beams which combine high brightness with small energy spread. The source is based on creating very cold ion beams by near-threshold photoionization of a laser-cooled and trapped atomic gas. We present ab initio numerical calculations of the generation of ultracold beams in a realistic acceleration field and including all Coulomb interactions, i.e., both space charge effects and statistical Coulomb effects. These simulations demonstrate that with existing technology reduced brightness values exceeding 105 A m−2 sr−1 V−1 are feasible at an energy spread as low as 0.1 eV. The estimated spot size of the ultracold ion source in a FIB instrument ranges from 10 nm at a current of 100 pA to 0.8 nm at 1 pA.