Enhancing quantum sensing The quantum properties of the nitrogen vacancy (NV) defect in diamond can be used as an atomic compass needle that is sensitive to tiny variations in magnetic field. Schmitt et al. and Boss et al. successfully enhanced this sensitivity by several orders of magnitude (see the Perspective by Jordan). They applied a sequence of pulses to the NV center, the timing of which was set by and compared with a highly stable oscillator. This allowed them to measure the frequency of an oscillating magnetic field (megahertz bandwidth) with submillihertz resolution. Such enhanced precision measurement could be applied, for example, to improve nuclear magnetic resonance-based imaging protocols of single molecules. Science , this issue p. 832 , p. 837 ; see also p. 802
Enhancing quantum sensing The quantum properties of the nitrogen vacancy (NV) defect in diamond can be used as an atomic compass needle that is sensitive to tiny variations in magnetic field. Schmitt et al. and Boss et al. successfully enhanced this sensitivity by several orders of magnitude (see the Perspective by Jordan). They applied a sequence of pulses to the NV center, the timing of which was set by and compared with a highly stable oscillator. This allowed them to measure the frequency of an oscillating magnetic field (megahertz bandwidth) with submillihertz resolution. Such enhanced precision measurement could be applied, for example, to improve nuclear magnetic resonance-based imaging protocols of single molecules. Science , this issue p. 832 , p. 837 ; see also p. 802
Enhancing quantum sensing The quantum properties of the nitrogen vacancy (NV) defect in diamond can be used as an atomic compass needle that is sensitive to tiny variations in magnetic field. Schmitt et al. and Boss et al. successfully enhanced this sensitivity by several orders of magnitude (see the Perspective by Jordan). They applied a sequence of pulses to the NV center, the timing of which was set by and compared with a highly stable oscillator. This allowed them to measure the frequency of an oscillating magnetic field (megahertz bandwidth) with submillihertz resolution. Such enhanced precision measurement could be applied, for example, to improve nuclear magnetic resonance-based imaging protocols of single molecules. Science , this issue p. 832 , p. 837 ; see also p. 802
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
Quantum technologies are expected to significantly change our world in the next decades and the possible applications are diverse – ranging from quantum computation and encryption to metrology with unprecedented sensitivity. This thesis focuses on quantum sensing and imaging based on single nitrogen-vacancy (NV) centres in diamond to measure magnetic fields. Its electronic spin qualifies this point defect as a highly sensitive quantum sensor and its atomic size offers nanoscale spatial resolution. The simple optical initialisation and readout, together with the relatively long coherence time at ambient conditions, make NV centres promising candidates for biological applications and in particular for nuclear magnetic resonance (NMR) on the nanoscale. Recording the spectral information on the nanoscale allows to determine the structure of single or just a few molecules. However, the current main problems and challenges include insufficient spectral resolution, artificial signals and overall poor performance. In this thesis new spectroscopic techniques which tackle these issues are presented. First, it is shown that by randomisation of control pulse phases spurious harmonic signals can be suppressed, which otherwise complicate spectrum interpretation and can lead to false signal identification. At the same time the effects of pulse imperfections are mitigated. Furthermore, a protocol allowing to measure with a coherence independent spectral resolution is presented. It is demonstrated that linewidths below 1mHz are possible, which is an improvement of more than seven orders of magnitude compared to traditional methods. Due to its simple implementation, the protocol is relevant for many applications. Initially developed to measure signals oscillating up to several megahertz, it is further shown that modifications allow to extend the frequency range into the gigahertz domain. Finally, quantum frequency discrimination with the task to differentiate between two frequency distributions using a quantum sensor is analysed. An optimised protocol is introduced and the influences of different readout strategies are discussed with respect to the probability to make an incorrect decision. These findings are useful for diagnostic tests in NMR.
Wide-field quantum magnetometry using nitrogen-vacancy (NV) center in diamond can be a breakthrough for a nuclear magnetic resonance (NMR) in a small volume, which is important for biological applications. Although the coherence time of the electron spin of the NV center results in a limited frequency resolution for diamond magnetometry in the range 10–100 kHz, recent studies have shown that a phase-sensitive protocol can circumvent this limit using a confocal setup. We proposed a new measurement protocol, “iQdyne,” which facilitates an improved frequency resolution of wide-field imaging, unencumbered by the coherence limit imposed by the NV center. We demonstrated wide-field magnetometry with a frequency resolution of 238 mHz and a magnetic sensitivity of 65 nT/Hz1/2, which are superior to those obtained using a conventional XY8-based technique, and showed the potential of the iQdyne protocol for the wide-field NMR imaging.
We investigate the application of amplitude-shaped control pulses for enhancing the time and frequency resolution of multipulse quantum sensing sequences. Using the electronic spin of a single nitrogen-vacancy center in diamond and up to 10 000 coherent microwave pulses with a cosine square envelope, we demonstrate 0.6-ps timing resolution for the interpulse delay. This represents a refinement by over 3 orders of magnitude compared to the 2-ns hardware sampling. We apply the method for the detection of external ac magnetic fields and nuclear magnetic resonance signals of ^{13}C spins with high spectral resolution. Our method is simple to implement and especially useful for quantum applications that require fast phase gates, many control pulses, and high fidelity.
Quantum sensing has witnessed rapid development and transition from laboratories to practical applications in the past decade. Applications of quantum sensors, ranging from nanotechnologies to biosensing, are expected to benefit from quantum sensors' unprecedented spatial resolution and sensitivity. Solid-state spin systems are particularly attractive platforms for quantum sensing technologies because room temperature operation is viable while reaching the quantum limits of sensitivity. Among various solid-state spin systems, nitrogen-vacancy (NV) centers in diamond demonstrated high-fidelity initialization, coherent control, and high contrast readout of the electron spin state. However, electron spin coherence due to noise from the surrounding spin bath and this environment effect limits the sensitivity of NV centers. Thus, a critical task in NV center-based quantum sensing is sensitivity enhancement through coherence protection. Several strategies, such as dynamical decoupling techniques, feedback control, and nuclear spin-assisted sensing protocols, have been developed and realized for this task. Among these strategies, nuclear spin-assisted protocols have demonstrated greater enhancement of electron spin coherence. In addition, the electron and nuclear spin pair of an NV center in diamond naturally allows the application of the nuclear spin-assisted sensitivity enhancement protocol. Owing to long nuclear coherence times, further enhancement of sensitivity can be achieved by exploiting active nuclear spins (e.g., 14N, 13C) in the proximity of an NV center as memory ancillas when coupled with the NV center. Here, we review the spin properties of NV centers, mechanisms of the nuclear spin-assisted protocol and its gate variation, and the status of quantum sensing applications in high-resolution nuclear spin spectroscopy, atomic imaging, and magnetic field sensing. We discuss the potential for commercialization, current challenges in sensitivity enhancement, and conclude with future research directions for promoting the development of nuclear spin-assisted protocol and its integration into industrial applications.